Capacitive sensor

NivoCapa® - NC 8100

Application area

The capacitive level sensor NivoCapa® 8100  is a simple and cost-effective solution for level measurement of liquids or oils. Interface measurement is possible as well. It can be used in large storage tanks, small process vessels, buffer tanks, hoppers, sumps, bypass or downtubes. The different gadget versions make installations from above and below possible and – due to remote housing – can also be used in vibrating environments or in areas of  limited space.

Technical Data

Measurement principleCapacitive
Measuring task
  • Continuous level measurement
  • Interface level measurement
Version
  • Coated Rod version
  • Rope version
  • Coaxial version
  • Coated rope version
MediumLiquids
Mounting position
  • top
  • in a Bypass
  • on a Socket
Ambient temperature-40°C … +85°C (-40 … +185°F)
Process temperature-40°C … +200°C (-40°F … +392°F)
Process pressure-1 bar … +35 bar (-14.5 psi … +511 psi)
Minimum sensitivityDK ≥ 1.6
Housing typeflameproof
Housing materialAluminium
Housing protection ratingIP68, Type 4
Threaded connection
  • ≥ G 3/4″
  • ≥ NPT 3/4″
Flange connection
  • ≥ DN25
  • ≥ 1″
Hygienic fittings
Wetted materials
  • Stainless steel 1.4404 (316L)
  • PEEK
  • FKM
  • FFKM
  • PFA
Mechanical load
  • rope: 18,5 kN
  • rod: 30 Nm
Accuracy0.5% of actual measurement value
Min. immersion length
  • rod: 300 mm (11.8″)
  • rope: 1000 mm (39.37″)
Max. immersion length
  • rod: 5 m (16.49′)
  • rope: 25 m (82′)
Power supply12…30V DC
Signal output4…20 mA (2-wire)
Approvals
  • CE
  • General purpose
  • ATEX
  • INMETRO
  • FM
  • CSA
Explosion protection
  • Dust Ignitionproof (Ex t)
  • Intrinsic Safe (Ex i)
  • Explosionproof/ Flameproof (Ex d)
Hygienic / Pharma
Ship approvalLloyd’s
Overfill protection
SIL qualification
Further approvals
User Interfacepush buttons + rotary switch
Optical indicatorDisplay
Adjustment possibility
  • self diagnostics
  • adjustable measurement range