Photoelectric Sensor with Separate Digital Amplifier (Laser-type)
E3C-LDA[]N
Variable Laser Beam for Spot, Line, or Area Detection
Sensor Heads
Type |
Diffuse-reflective |
Coaxial Retro-reflective (with MSR function) |
||||||
Item |
E3C-LD11N |
E3C-LD11N + |
E3C-LD11N + |
E3C-LR11N |
E3C-LR11N + |
E3C-LR11N + |
E3C-LR12N |
|
Light source |
Red semiconductor laser diode |
Red semiconductor laser diode |
1 mW max. |
|||||
Sensing |
Super |
30 to 250 mm |
2 m |
700 mm |
400 mm |
2 m |
||
High-speed |
30 to 250 mm |
2 m |
700 mm |
400 mm |
2 m |
|||
Standard |
30 to 700 mm |
5 m |
1,300 mm |
700 mm |
5 m |
|||
Giga Mode |
30 to 1000 mm |
7 m |
1,700 mm |
900 mm |
7 m |
|||
Focus *3 |
0.8 mm max. |
33 mm |
33 × 15 mm |
0.8 mm max. |
28 mm |
28 × 16 mm |
2.0-mm dia. |
|
Functions |
Variable focal point mechanism (focus adjustment) *4, |
|||||||
Indicators |
LDON indicator: Green; Operation indicator: Orange |
|||||||
Ambient |
Incandescent lamp: 3,000 lx |
|||||||
Ambient |
Operating: -10 to 55°C, Storage: -25 to 70°C (with no icing or condensation) |
|||||||
Ambient |
Operating/storage: 35% to 85% (with no condensation) |
|||||||
Insulation |
20 MΩ min. at 500 VDC |
|||||||
Dielectric |
1,000 VAC at 50/60 Hz for 1 minute |
|||||||
Shock |
Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward) |
|||||||
Vibration |
Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each |
|||||||
Degree of |
IP40 (IEC) |
IP40 (IEC 60529) |
||||||
Connection |
Connector (standard cable length: 2 m) |
|||||||
Materials |
Case and cover: ABS |
Case and cover: ABS |
||||||
Weight |
Approx. 85 g |
Approx. 100 g |
||||||
Accessories |
Instruction manual, Laser warning labels (English) |
1. The sensing distance of E3C-LD11N is the value of the white paper.
2. The sensing distance of E3C-LR[][]N is values apply when a E39-R12 Reflector is used.
3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance.
The radius is defined by light intensity of 1/e2 (13.5%) of the central light intensity.
Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured.
4. The E3C-LR12N has a fixed beam size (the focal point cannot be changed).
Amplifier Units
Model |
NPN output |
E3C-LDA21N |
E3C-LDA6N |
E3C-LDA7N |
PNP output |
E3C-LDA51N |
E3C-LDA8N |
E3C-LDA9N |
|
Connection |
Pre-wired |
Wire-saving Connector |
||
Applicable Amplifier Unit |
E3C-L[][][]N |
|||
Outputs |
2 outputs |
2 outputs |
1 output |
|
External input *1 |
1 input |
--- |
1 input |
|
Supply voltage |
12 to 24 VDC ±10%, ripple (p-p) 10% max. |
|||
Power consumption |
Power consumption: 1080 mW max. (when the power supply voltage is 24 V, the current consumption is 45 mA max.) |
|||
Control output |
Load power supply voltage: 26.4 VDC, open collector output type (depends on the NPN/PNP output format) |
|||
Indicators |
7-segment displays (Threshold Level display: green, Incident Light Level display: white) |
|||
Protection circuits |
Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
|||
Response |
Super-high- |
Operate or reset: 80 μs |
||
High-speed |
Operate or reset: 250 μs |
|||
Standard |
Operate or reset: 1 ms |
|||
Giga mode |
Operate or reset: 4 ms |
|||
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, power tuning, percentage tuning) or manual adjustment |
|||
Maximum connectable Units |
16 |
|||
No. of Units |
Super |
0 |
||
High-speed |
10 |
|||
Standard |
10 |
|||
Giga Mode |
10 |
|||
Functions |
Dynamic |
Provided |
||
Timer |
Select from timer disabled, OFF-delay, ON-delay or one-shot timer. 1 to 9,999 ms |
|||
Zero reset |
Negative values can be displayed. (Threshold value is shifted.) |
|||
Resetting |
Initial reset (factory defaults) |
|||
Power tuning |
Select from ON or OFF. |
|||
Output 1 |
Select from normal detection mode or area detection mode. |
|||
Output 2 |
Select from normal detection mode, alarm output mode or error output mode. |
--- |
||
External input |
Select from input OFF, |
--- |
Select from input OFF, |
|
Hysteresis |
Select from standard setting or user setting. |
|||
Ambient temperature |
Operating: |
|||
Ambient humidity range |
Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
|||
Altitude |
2000 m max. |
|||
Installation environment |
Pollution degree 3 (as per IEC 60947-1) |
|||
Insulation resistance |
20 MΩ (at 500 VDC) |
|||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min |
|||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 for 3 times each in X, Y, and Z directions |
|||
Weight |
Approx. 115 g/ |
Approx. 60 g/approx. 20 g |
||
Materials |
Case |
Polycarbonate (PC) |
||
Protective |
Polycarbonate (PC) |
|||
Cable |
PVC |
|||
Accessories |
Instruction manual, compliance sheet |
1. The following details apply to the input.
Contact input (relay or switch) |
Non-contact input (transistor) |
Input time *1-1 |
|
NPN |
ON: Shorted to 0 V |
ON: 1.5 V max. |
ON: 9 ms min. |
OFF: Open or shorted to Vcc |
OFF: Vcc - 1.5 V to Vcc |
||
PNP |
ON: Shorted to Vcc |
ON: Vcc - 1.5 V to Vcc |
|
OFF: Open or shorted to 0 V |
OFF: 1.5 V max. |
1-1. Input time is 25 ms (ON)/(OFF) only when (in tUnE) input is selected.
2. Separately purchase the E3X-CN21 Master Connector (4-conductor) when using this product as a single unit or as a master unit, or the E3X-CN22 Slave Connector (2-conductor) when using as a slave unit. Either Connector can be used.
3. The tuning will not change the number of units. In standard mode and giga mode, set the threshold value to 400 or more.