Smart Sensors Laser Displacement Sensors CMOS Type
ZX2
Stable measurement that is unaffected by workpiece changes. The simple setting for everyone.
Diffuse-reflective Sensor Heads
Model |
ZX2-LD50L |
ZX2-LD50 |
ZX2-LD100L |
ZX2-LD100 |
Optical system |
Diffuse reflective |
|||
Light source |
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1mW max. |
|||
EN class 2, FDA class 1 *5 |
||||
Measurement center |
50 mm |
100 mm |
||
Measurement range |
±10 mm |
±35 mm |
||
Beam shape |
Line |
Spot |
Line |
Spot |
Beam size *1 |
Approx. 60 μm × |
Approx. 60 μm dia. |
Approx.110 μm × |
Approx.110 μm dia. |
Resolution *2 |
1.5μm |
5μm |
||
Linearity *3 |
±0.05% F.S. |
±0.1% F.S. |
±0.05% F.S. |
±0.1% F.S. |
Temperature |
0.02% F.S./°C |
|||
Ambient illumination |
Incandescent lamp: 10,000 lx max. (on light receiving side) |
|||
Ambient temperature |
Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) |
|||
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
|||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min. |
|||
Vibration resistance |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions |
|||
Shock resistance |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
|||
Degree of protection |
IEC60529, IP67 |
|||
Connection method |
Connector connection (standard cable length: 500 mm) |
|||
Weight (packed state) |
Approx. 160 g (main unit only: Approx. 75 g) |
|||
Materials |
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC |
|||
Accessories |
Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning |
Regular-reflective Sensor Head
Model |
ZX2-LD50L |
Optical system |
Regular reflective |
Light source (wave length) |
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 |
Measurement center point |
48 mm |
Measurement range |
±5 mm |
Beam shape |
Spot |
Beam size *1 |
Approx. 60 μm dia. |
Resolution *2 |
1.5 μm |
Linearity *3 |
±0.3%F.S. (entire range) |
Temperature |
0.06%F.S./°C |
Ambient illumination |
Incandescent lamp: 10,000lx max. (on light receiving side) |
Ambient temperature |
Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) |
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance |
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance |
300 m/s2 3 times each in six directions (up/down,left/right,forward/backward) |
Degree of protection |
IEC 60529, IP67 |
Connection method |
Connector connection (standard cable length: 500 mm) |
Weight (packed state) |
Approx.160g (Sensor Head only: Approx.75g) |
Materials |
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC |
Accessories |
Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser |
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
1. Beam size: Defined as 1/e2 (13.5 %) of the center optical intensity at the minimum value of the measurement range (effective value).
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object. Correct measurements may not be obtained if the workpiece is smaller than the beam size.
2. Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models: white ceramic object, regular-reflective models:1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.) Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
3. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron's standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50(L): 20 mm)
4. Temperature characteristic: Value for the case the space between the sensor head and Omron’ s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
5. These Sensors are classified as Class 1 under EN 60825-1 and the regulations of Laser Notice No. 56 for FDA certification. CDRH registration has been completed.
Amplifier Units
Model |
ZX2-LDA11 |
ZX2-LDA41 |
Measurement period *1 |
Min. 30 μs |
|
Response time |
60 μs, 120 μs, 240 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, |
|
Analog output *2 |
4 to 20 mA, Max. load resistance: 300Ω/±5 VDC or 1 to 5 VDC, Output impedance: 100Ω |
|
Judgement outputs |
NPN open-collector outputs, 30 VDC, 50 |
PNP open-collector outputs, 30 VDC, 50 |
Laser OFF input, zero |
ON: Short-circuited with 0-V terminal or |
ON: Supply voltage short-circuited or supply |
Functions |
Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak |
|
Indications |
Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main |
|
Power supply voltage |
10 to 30 VDC, including 10% ripple (p-p) |
|
Power consumption |
3,000 mW max. (at 24 VDC: 125 mA max., at 12 VDC: 250 mA max.) |
|
Ambient temperature |
Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation) |
|
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min. |
|
Vibration resistance |
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions |
|
Shock resistance |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
|
Degree of protection |
IEC60529, IP40 |
|
Connection method |
Prewired (standard cable length: 2 m) |
|
Weight (packed state) |
Approx. 200 g (main unit only: Approx. 135 g) |
|
Materials |
Case: PBT (polybutylene terephtahalate), Cover: Polycarbonate, Display: Methacrylic resin, |
|
Accessories |
Instruction sheet |
1. In the case of Omron’s standard target object (white ceramic)
2. Select current output (4 to 20 mA) and voltage output (±5V or 1 to 5V) by MENU mode.
3. Calculating unit (ZX2-CAL) is necessary. Calculations are possible for up to two amplifier units. Mutual interference prevention is possible for up to five amplifier units.
Calculating Unit
Model |
ZX2-CAL |
Applicable Amplifier Units |
ZX2-LDA11, ZX2-LDA41 |
Current consumption |
12 mA max. (supplied from the Smart Sensor Amplifier Unit) |
Ambient temperature |
Operating: 0 to +50°C, storage: -15 to +70°C (with no icing or condensation) |
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
Connection method |
Connector |
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
Materials |
Case: ABS, Display: Methacrylic resin |
Weight (packed state) |
Approx. 50g (Calculating Unit only: Approx. 15g) |
Accessories |
Instruction sheet |
ZX2-series Communications Interface Unit
Model |
ZX2-SF11 |
||
Power supply voltage |
10 to 30 V DC ±10% (including 10% ripple (p-p)) |
||
Power consumption |
720 mW max. (at 24 V: 30 mA max., at 12 V: 60 mA max.) |
||
Applicable Amplifier Units |
ZX2-LDA[][] (Production after November 2013) |
||
Applicable Amplifier |
Sensor Amplifier Unit version: V1.330 or higher |
||
Max. No. of Amplifier |
5 |
||
Commu- |
Port |
RS-232C (9-pin, D-Sub connector) |
|
Communications method |
Full duplex |
||
Synchronization method |
Start/stop synchronization |
||
Transmission code |
ASCII |
||
Baud rate |
38,400 (at shipping)/9,600 bps switchable |
||
Data bit length |
8 bits |
||
Parity check |
None |
||
Stop bit length |
1 bit |
||
Data |
Receiving |
CR or CR + LF is automatically recognized. |
|
Sending |
CR + LF fixed |
||
Indicators |
Power supply: green, Sensor communications: green, Sensor |
||
Protective circuits |
Power supply reverse polarity protection |
||
Ambient temperature |
Operating: 0 to 50°C, storage: -15 to 60°C |
||
Ambient humidity |
Operating and storage: 35% to 85% |
||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min, |
||
Materials |
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate |
||
Accessories |
Instruction sheet, 2 clamps |