V440-F

Symbologies
 *1

1D Symbologies

Code 39, Code 128, BC412, Interleaved 2 of 5, UPC/EAN,
 Codabar, Code 93, Pharmacode, PLANET, Postnet,
 Japanese Post, Australian Post, Royal Mail, Intelligent Mail,
 KIX

2D Symbologies

Data Matrix (ECC 0-200), QR Code, Micro QR Code,
 Aztec Code, DotCode, DMRE

Stacked Symbologies

PDF417, MicroPDF417, GS1 Databar
 (Composite and Stacked)

Reading
 Performance
 *2

Number of Reading Digits

No Upper Limit
 (depending on bar width and reading distance)

Reading Distance /
 Field of View

Based on Lens Selection and Code Size

Pitch Angle (α) *3

±30°

Skew Angle (β) *3

±30°

Tilt Angle (γ) *3

±180°

Image

Resolution, Pixel Size

2464 (H) x 2056 (V) - 3.45 μm Pixel Size

Color / Monochrome

Monochrome CMOS

Shutter

Global Shutter

Frames per Second

35 FPS for 5 MP

Exposure

16 μs to 400 msec

Image Logging

FTP

Trigger

External Trigger (Edge or Level), Communication Trigger
 (Ethernet, RS-232C)

Trigger to Strobe Latency + Jitter

320 μs + 65 μs

I/O
 Specifications

Input Signals

Trigger Input, New Master, and Default -
 Bi-Directional Inputs, Optoisolated, 4.5 - 28 V rated
 (10 mA [] 28 VDC)

Output Signals

3 Signals: Bi-Directional, Optoisolated, 1 - 28 V rated,
(ICE < 100 mA at 24 VDC, current limited by user)

Communication

Connectivity

RS-232C, Ethernet TCP/IP, EtherNet/IP™, PROFINET

Ethernet Specifications

1000BASE-T

Indicator LEDs

LINK (Amber), PWR (Green)

Power Supply Voltage

Power over Ethernet (IEEE 802.3af) / 24 VDC +/- 20%,
 External Input via IO *4

Current Consumption

PoE (44-57 VDC): 0.10 A or 24 VDC: 0.15 A

Weight

Main Body Only

Approx. 103.4 g

Packaging Weight

Approx. 219.1 g

Dimensions

40 mm (W) × 61 mm (D) × 30 mm (H) Note:
 Depth measurement excludes connector

Accessories

ReadMeFirst, CE Compliance Sheet,
 Protocol Support Table

Materials

Aluminum Diecast, Alumite (Black)

Software

WebLink 3.0

Environmental /
 Immunity *5

Operating Temperature

0° to 40°C

Storage Temperature

-25° to 65°C (No Icing or Condensation)

Ambient Atmosphere

No Corrosive Gases

Humidity
 (Operating and Storage)

5% to 95% (Non-Condensing)

Destructive Vibration
 Resistance

Oscillation Frequency: 10 to 150Hz,
 Half Amplitude: 0.35 mm,
 Vibration Direction: X/Y/Z,
 Sweep Time: 8 Minutes / Count, Sweep Count: 10 Times

Drop Specification

Impact Force: 150 m/s2, Test Direction: 6 Directions,
 3 Times Each (Up / Down, Front / Behind, Left / Right)

Water Resistance Rating

IP40 per IEC 60529

EMC / Safety

FCC 47 CFR part 15 Subpart B, ICES-003, EN 55032,
 EN 55035, AS/NZS CISPR32, CNS 13438, KN32, KN35,
 UL 62368-1, UL 60950-1
 FCC, UL, CE, UKCA, RCM, KC *6

1. These symbologies are supported based on Omron’s read capability validation standard. Omron recommends that validation be performed for each application.
2. Unless otherwise specified, reading performance is defined with center of field of view, angle R = .
 3. 
image

 

 

4. Code reader operates External Input at 24 VDC when supplied at the same time as PoE.
 5. In an electrically noisy environment, use only the V440-F in combination with a noise filter cable (V430-W[]F-[]M) to ensure proper operation.
 6. FCC = United States
   UL = United States
   CE = European Union
   UKCA = Great Britain (England / Wales / Scotland)
   RCM = Australia / New Zealand
   KC = South Korea