Ratings and Performance

Model

V400-R2CF65

V400-R2CF125

Direction of view

Front view

Applicable
 codes *1

Bar code

WPC (JAN/EAN/UPC), Codabar (NW-7), ITF, Industrial 2 of 5 (STF),
 Code39, Code93, Code128, GS1-128 (EAN-128), GS1-Databar (RSS-14),
 GS1-Databar Limited (RSS Limited), GS1-Databar Expanded
 (RSS Expanded),
 GS1-Databar Composite (RSS Composite)

Number of reading digits

QR code, DataMatrix (ECC200), MicroQR code, PDF417, MicroPDF417,
 AztecCode, MaxiCode, Codablock-F

Reading
 performance
 *2

Number of reading digits

No upper limit (depends on bar width and reading distance)

Light source

Two red LEDs (wave length: 617 nm)

Aiming light

One green LED (wave length: 528 nm)

Minimum resolution

Bar code: 0.076 mm
 2D code: 0.127 mm

Bar code: 0.127 mm
 2D code: 0.212 mm

Image capture device

Monochrome CMOS

Effective number of pixels

754 × 480 pixels

Working distance (WD)

65 mm

125 mm

Field of view

Approximately 48 × 31
 (for WD = 65 mm)

Approximately 93 × 59
 (for WD = 125 mm)

Pitch angle (α)

±50º

Skew angle (β)

±50º

Tilt angle (γ)

±180º

Reading of bar codes
 on curved surfaces (R)

R 20 mm (UPC 12 line)

Interface

Communication
 specification

RS-232C

OK/NG outputs

NPN open collector output (cable work required)

Function setting method

Menu sheet reading, Sending commands from upper equipment,
 or SCAN button (only when executing code condition teaching)

Functional
 specifications

Reading trigger

External trigger (Transistor input)
 Trigger by command (RS-232C)
 Trigger a test reading by pressing the SCAN button on the product

OK/NG signals

• When the label is not registered
 OK signal: ON when reading is successful
 NG signal: Not used
 • When the label is registered
 OK signal: ON when reading result matches registered label
 NG signal: ON when reading result does not match registered label

Indication LED

• When reading
 Read confirmation LED (green) illuminates when reading is successful.
 • When teaching
 Read confirmation LED (green) blinks during execution.
 When teaching is successful, read confirmation LED (green) illuminates
 and buzzer sounds.
 When teaching fails, read confirmation LED (red) illuminates and
 BAD buzzer sounds. *3

Buzzer

Notifies a successful reading with a buzzer sound (Muting available)

Power supply
 specification

Power voltage

4.5 to 5.5 VDC

Consumption current

During operation: 265 mA or less; during standby: 70 mA or less

Environmental
 specifications

Ambient temperature
 range

At operation: 0 to + 45ºC; At storage: -10 to + 60ºC

Ambient humidity range

At operation and storage: 20 to 85% RH (with no icing or condensation)

Ambient atmosphere

No corrosive gases

Ambient light

Fluorescent lamp: 10,000 lx or less, Sunlight: 100,000 lx or less

Vibration resistance

10 to 150 Hz, half amplitude 0.35 mm, 3 directions (X/Y/Z), 8 minutes
 each 10 times

Degree of protection

IP65 (IEC60529)

Weight

Main unit only

Approximately 90 g

Including accessories

Approximately 200 g (including mounting bracket and screws)

Packaged weight

Approximately 280 g (including packing carton)

Dimensions

Main unit

Approximately 41 (W) × 33 (D) × 24 (H) mm

Packing carton

Approximately 240 (W) × 110 (D) × 40 (H) mm

Input/output connector

Round DIN connector

Code length

Approximately 1.5 m

Minimum bending radius of cord

Approximately 23 mm

Accessories

Operation manual, menu sheet, mounting bracket, M2 × 6 screws (two),
 M5 ×10 screws (two)

Material,
 Color

Case

PC, PET, black

Reading window

PMMA, transparent

Cable

Polyvinyl chloride (PVC), black

Mounting bracket

SUS304, silver

1. These are the code types supported based on Omron’s read capability validation standard. It is recommended that the customer do its own validation in its actual work environment.
 2. Unless otherwise specified, the reading performance is defined with angle α = 0º, β = +15º, γ = 0º, R = ∞; illuminance:100 to 2001x, reading rate: 90% or more.
 3. The BAD buzzer is two low-pitched buzz sounds.
 •QR code is the registered trademark of DENSO WAVE. 

Reading range performance (typical example)

 

 

 

 

 

 

 

 

 

Explained with examples of following conditions:  •Contrast: MRD 63% (PCS = 0.9)
 •Installation condition:
     Pitch angle α = 0°, skew angle β = 15°
     Tilt angle γ = 0°, curvature R = ∞
 •Reading rate: 90% or more in 10 tries

 

 

 

 

image

V400-R2CF125

2D code (typical example)

Code types

Resolution

Reading distance

Field-of-view size at reading distance

QR Code

0.212

95 to 115

70×44 to 85×54

0.381

60 to 185

44×28 to 137×87

Data Matrix

0.254

80 to 145

59×38 to 107×68

PDF417

0.169

85 to 130

63×40 to 96×61

0.254

65 to 180

48×30 to 133×85

Bar code (typical example)

Code types

Resolution

Reading distance

Field-of-view size at reading distance

Code39

0.127

90 to 125

66×42 to 93×59

0.254

70 to 190

52×33 to 141×89

0.508

65 to 235

48×30 to 174×110

Code128

0.2

80 to 160

59×38 to 118×75

UPC

0.33

55 to 185

40×25 to 137×87

V400-R2CF65

2D code (typical example)

Code types

Resolution

Reading distance

Field-of-view size at reading distance

QR Code

0.169

70 to 80

51×33 to 59×38

0.381

45 to 110

33×21 to 81×52

Data Matrix

0.212

65 to 90

48×31 to 66×42

PDF417

0.127

65 to 80

48×31 to 59×38

0.254

65 to 110

48×31 to 81×52

Bar code (typical example)

Code types

Resolution

Reading distance

Field-of-view size at reading distance

Code39

0.127

65 to 85

48×31 to 62×40

0.254

60 to 110

44×28 to 81×52

Code128

0.18

55 to 100

40×26 to 74×47

UPC

0.33

60 to 125

44×28 to 92×58