Electrode Bands / Underwater Electrode
F03-05, PH-1 / -2
Easy Mounting and Removal. Ideal for Applications in Deep Wells.
Electrode Bands
Model |
F03-05 3P |
F03-05 4P |
F03-05 5P |
Outer sheath |
PVC |
||
Core |
SUS304, 0.3 dia. x 21 twisted wires |
||
Weight |
Approx. 110 g (1 m) |
Approx. 140 g (1 m) |
Approx. 180 g (1 m) |
Operating temperature |
-10 to +60°C (with no icing) * |
||
Applicable Electrode Holders |
PS-3S, -4S, -5S BF-3, -5 |
*The Electrode Band cannot be used in flowing water, liquids over 60°C, or liquids which corrode PVC or stainless steel.
Underwater Electrodes
Model |
PH-1 |
PH-2 |
|||
Vinyl cable |
Hypalon cable |
Vinyl cable |
Hypalon cable |
||
Cable length |
100 m max. |
||||
Operating temperature |
-10 to +60°C |
-30 to +70°C |
-10 to +60°C |
-30 to +70°C |
|
Weight |
Electrode + 1 m cable |
Approx. 140 g |
Approx. 140 g |
Approx. 230 g |
Approx. 230 g |
Cable (per meter) |
Approx. 40 g |
Approx. 40 g |
Approx. 60 g |
Approx. 60 g |
Note: 1. The PH-1 and PH-2 are vinyl cables unless specified otherwise.
2. "ビニソフト" is printed in Japanese on the actual vinyl cable.
3. Hypalon is a registered trademark of Mitsui Chemicals, Inc.
Required No. of Electrode Band Accessories (Order Separately)
Product |
Model |
Weight per unit (g) |
F03-05 3P |
F03-05 4P |
F03-05 5P |
Electrode Band |
F03-06 |
Approx. 20 |
3 |
4 |
5 |
Electrode Band |
F03-07 |
Approx. 50 |
3 to 4 |
4 to 6 |
5 to 8 |
Electrode Band |
F03-08 |
Approx. 1 |
2 |
3 |
4 |
Electrode Band |
F03-09 |
Approx. 10 |
2 |
3 |
4 |
Electrode Band |
F03-10 |
Approx. 5 |
1 |
1 |
1 |
Note: One tube of F03-10 (adhesive) can be used for approximately 5 times of end cap fixation.
Electrode Bands
Model |
F03-05 3P |
F03-05 4P |
F03-05 5P |
Outer sheath |
PVC |
||
Core |
SUS304, 0.3 dia. x 21 twisted wires |
||
Weight |
Approx. 110 g (1 m) |
Approx. 140 g (1 m) |
Approx. 180 g (1 m) |
Operating temperature |
-10 to +60°C (with no icing) * |
||
Applicable Electrode Holders |
PS-3S, -4S, -5S BF-3, -5 |
*The Electrode Band cannot be used in flowing water, liquids over 60°C, or liquids which corrode PVC or stainless steel.
Underwater Electrodes
Model |
PH-1 |
PH-2 |
|||
Vinyl cable |
Hypalon cable |
Vinyl cable |
Hypalon cable |
||
Cable length |
100 m max. |
||||
Operating temperature |
-10 to +60°C |
-30 to +70°C |
-10 to +60°C |
-30 to +70°C |
|
Weight |
Electrode + 1 m cable |
Approx. 140 g |
Approx. 140 g |
Approx. 230 g |
Approx. 230 g |
Cable (per meter) |
Approx. 40 g |
Approx. 40 g |
Approx. 60 g |
Approx. 60 g |
Note: 1. The PH-1 and PH-2 are vinyl cables unless specified otherwise.
2. "ビニソフト" is printed in Japanese on the actual vinyl cable.
3. Hypalon is a registered trademark of Mitsui Chemicals, Inc.
Required No. of Electrode Band Accessories (Order Separately)
Product |
Model |
Weight per unit (g) |
F03-05 3P |
F03-05 4P |
F03-05 5P |
Electrode Band |
F03-06 |
Approx. 20 |
3 |
4 |
5 |
Electrode Band |
F03-07 |
Approx. 50 |
3 to 4 |
4 to 6 |
5 to 8 |
Electrode Band |
F03-08 |
Approx. 1 |
2 |
3 |
4 |
Electrode Band |
F03-09 |
Approx. 10 |
2 |
3 |
4 |
Electrode Band |
F03-10 |
Approx. 5 |
1 |
1 |
1 |
Note: One tube of F03-10 (adhesive) can be used for approximately 5 times of end cap fixation.