Fiber Unit Build-in Lens Series
E32-LT / LD
High-power, Stable Detection. Is the Standard for the Future!
Through-beam Fiber Units
Type |
Appearance |
Bending |
Sensing distance (mm) |
Optical |
Models |
||
Sensing |
Aperture |
E3X-HD |
E3NX-FA |
||||
Top-view |
15° |
|
R25 |
GIGA: 4,000 * |
GIGA: 4,000 * |
2.3 dia. |
E32-LT11 2M |
Flexible, |
GIGA: 4,000 * |
GIGA: 4,000 * |
E32-LT11R 2M |
* The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1.The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
and SHS: Super-high-speed mode (30 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
Reflective Fiber Units
Type |
Appearance |
Bending |
Sensing distance (mm) |
Optical |
Models |
||
Sensing |
Aperture |
E3X-HD |
E3NX-FA |
||||
Top-view |
15° |
|
R25 |
GIGA: 860 |
GIGA: 1,290 |
(0.1 dia./ |
E32-LD11 2M |
Flexible, |
GIGA: 840 |
GIGA: 1,260 |
E32-LD11R 2M |
Note 1.The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
and SHS: Super-high-speed mode (30 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
Note 3. The sensing distances for Reflective Fiber Units are for glossy white paper.