Product Category

Photoelectric Sensor with Separate Digital Amplifier (Laser-type)

E3C-LDA[]N

Variable Laser Beam for Spot, Line, or Area Detection

Sensor Heads

Type

Diffuse-reflective

Coaxial Retro-reflective (with MSR function)

Item

E3C-LD11N

E3C-LD11N +
 E39-P11

E3C-LD11N +
 E39-P21

E3C-LR11N

E3C-LR11N +
 E39-P31

E3C-LR11N +
 E39-P41

E3C-LR12N

Light source
 (wavelength)

Red semiconductor laser diode
 (650 nm),3 mW max.
 (JIS Class 2, IEC/EN Class 2,
 and FDA Class 2)

Red semiconductor laser diode
 (650 nm), 3 mW max. (JIS Class 2,
 IEC/EN Class 2, and FDA Class 2)

1 mW max.
 (JIS Class 1,
 IEC/EN Class
 1, and FDA
 Class 2)

Sensing
 distance
 *1, *2

Super
 High-speed
 Mode
 (SHS)

30 to 250 mm

2 m

700 mm

400 mm

2 m

High-speed
 Mode (HS)

30 to 250 mm

2 m

700 mm

400 mm

2 m

Standard
 Mode (Stnd)

30 to 700 mm

5 m

1,300 mm

700 mm

5 m

Giga Mode
 (GIGA)

30 to 1000 mm

7 m

1,700 mm

900 mm

7 m

Focus *3

0.8 mm max.
 (at distances
 up to 300 mm)

33 mm
 (at 150 mm)

33 × 15 mm
 (at 150 mm)

0.8 mm max.
 (at distances
 up to 1,000
 mm)

28 mm
 (at 150 mm)

28 × 16 mm
 (at 150 mm)

2.0-mm dia.
 (at distance up
 to 1,000 mm)

Functions

Variable focal point mechanism (focus adjustment) *4,
 optical axis adjustment mechanism (axis adjustment)

Indicators

LDON indicator: Green; Operation indicator: Orange

Ambient
 illumination
 (Receiver side)

Incandescent lamp: 3,000 lx

Ambient
 temperature

Operating: -10 to 55°C, Storage: -25 to 70°C (with no icing or condensation)

Ambient
 humidity

Operating/storage: 35% to 85% (with no condensation)

Insulation
 resistance

20 MΩ min. at 500 VDC

Dielectric
 strength

1,000 VAC at 50/60 Hz for 1 minute

Shock
 resistance

Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward)

Vibration
 resistance

Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each

Degree of
 protection

IP40 (IEC)

IP40 (IEC 60529)

Connection
 method

Connector (standard cable length: 2 m)

Materials

Case and cover: ABS
 Front surface filter: Methacrylic resin

Case and cover: ABS
 Front surface filter: Glass

Weight
 (packed state)

Approx. 85 g

Approx. 100 g

Accessories

Instruction manual, Laser warning labels (English)

1. The sensing distance of E3C-LD11N is the value of the white paper.
 2. The sensing distance of E3C-LR[][]N is values apply when a E39-R12 Reflector is used.
 3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance.
   The radius is defined by light intensity of 1/e2 (13.5%) of the central light intensity.
   Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured.
 4. The E3C-LR12N has a fixed beam size (the focal point cannot be changed). 

Amplifier Units

Model

NPN output

E3C-LDA21N

E3C-LDA6N

E3C-LDA7N

PNP output

E3C-LDA51N

E3C-LDA8N

E3C-LDA9N

Connection
 method *2

Pre-wired

Wire-saving Connector

Applicable Amplifier Unit

E3C-L[][][]N

Outputs

2 outputs

2 outputs

1 output

External input *1

1 input

---

1 input

Supply voltage

12 to 24 VDC ±10%, ripple (p-p) 10% max.

Power consumption

Power consumption: 1080 mW max. (when the power supply voltage is 24 V, the current consumption is 45 mA max.)

Control output

Load power supply voltage: 26.4 VDC, open collector output type (depends on the NPN/PNP output format)
 Load current: 100 mA max. for 1 to 3 units use, 20 mA max. for 4 or more units joined.
 Residual voltage: Load current less than 10 mA: 1 V max., load current 10 to 100 mA: 2 V max.
 Off-state current: 0.1 mA max.

Indicators

7-segment displays (Threshold Level display: green, Incident Light Level display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green),
 and OUT selection indicator (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Response
 time

Super-high-
 speed
 mode (SHS)

Operate or reset: 80 μs

High-speed
 mode (HS)

Operate or reset: 250 μs

Standard
 mode
 (Stnd)

Operate or reset: 1 ms

Giga mode
 (GIGA)

Operate or reset: 4 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, power tuning, percentage tuning) or manual adjustment

Maximum connectable Units

16

No. of Units
 for mutual
 interference
 prevention
 *3

Super
 High-speed
 Mode (SHS)

0
 Note: The mutual interference prevention function is disabled when the detection mode is set to High Speed mode (SHS).

High-speed
 Mode (HS)

10

Standard
 Mode (Stnd)

10

Giga Mode
 (GIGA)

10

Functions

Dynamic
 power
 control (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay or one-shot timer. 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting
 settings

Initial reset (factory defaults)

Power tuning

Select from ON or OFF.

Output 1

Select from normal detection mode or area detection mode.

Output 2

Select from normal detection mode, alarm output mode or error output mode.

---

External input

Select from input OFF,
 tuning, power tuning,
 emission OFF or zero reset.

---

Select from input OFF,
 tuning, power tuning,
 emission OFF or zero reset.

Hysteresis
 width

Select from standard setting or user setting.

Ambient temperature
 range

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C
 Storage:
 -30 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above

Altitude

2000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Insulation resistance

20 MΩ (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Weight
 (packed state/sensor only)

Approx. 115 g/
 approx. 75 g

Approx. 60 g/approx. 20 g

Materials

Case

Polycarbonate (PC)

Protective
 cover

Polycarbonate (PC)

Cable

PVC

Accessories

Instruction manual, compliance sheet

1. The following details apply to the input. 


Contact input (relay or switch)

Non-contact input (transistor)

Input time *1-1

NPN

ON: Shorted to 0 V
 (Sourcing current: 1 mA max.)

ON: 1.5 V max.
 (Sourcing current: 1 mA max.)

ON: 9 ms min.
 OFF: 20 ms min.

OFF: Open or shorted to Vcc

OFF: Vcc - 1.5 V to Vcc
 (Leakage current: 0.1 mA max.)

PNP

ON: Shorted to Vcc
 (Sinking current: 3 mA max.)

ON: Vcc - 1.5 V to Vcc
 (Sinking current: 3 mA max.)

OFF: Open or shorted to 0 V

OFF: 1.5 V max.
 (Leakage current: 0.1 mA max.)

1-1. Input time is 25 ms (ON)/(OFF) only when (in tUnE) input is selected.
 
 2. Separately purchase the E3X-CN21 Master Connector (4-conductor) when using this product as a single unit or as a master unit, or the E3X-CN22 Slave Connector (2-conductor) when using as a slave unit. Either Connector can be used.
 3. The tuning will not change the number of units. In standard mode and giga mode, set the threshold value to 400 or more.