Built-in Power Supply Photoelectric Sensor
E3JK (NEW)
Long-distance Photoelectric Sensor That Supports AC/DC Power Supplies
|
Sensing method |
Through-beam |
|||||
|
Model |
E3JK-TR11-[] |
E3JK-TR12-[] |
E3JK-TR13-[] |
E3JK-TR14-[] |
||
|
Sensing distance |
40 m |
5 m |
40 m |
5 m |
||
|
Standard sensing object |
Opaque: 17-mm dia. min. |
|||||
|
Differential travel |
- |
|||||
|
Directional angle |
Both Emitter and Receiver 3° min. |
|||||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
||||
|
Power supply voltage |
24 to 240 VDC ±10%, |
|||||
|
Power |
DC |
3 W max. (Emitter 1.5 W max. Receiver 1.5 W max.) |
||||
|
AC |
3 W max. (Emitter 1.5 W max. Receiver 1.5 W max.) |
|||||
|
Control output |
Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1), |
|||||
|
Protection circuits |
- |
|||||
|
Life |
Mechanical |
50,000,000 times min. (switching frequency: 18,000 times/h) |
||||
|
Electrical |
100,000 times min. (switching frequency: 1,800 times/h) |
|||||
|
Response time |
20 ms max. |
|||||
|
Sensitivity adjustment |
One-turn adjuster Receiver (E3JK-TR1[]-D) only |
|||||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
|||||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
|||||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
|||||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
|||||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
|||||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||
|
Malfunction |
100 m/s2 for 3 times each in X, Y, and Z directions |
|||||
|
Degree of protection |
IEC 60529 IP64 |
|||||
|
Connection method |
Pre-wired (standard length: 2 m) |
|||||
|
Weight (packed state) |
Approx. 350 g |
|||||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
||||
|
Lens/Display |
Methacrylic resin |
|||||
|
Adjuster |
POM |
|||||
|
Cable |
PVC |
|||||
|
Bending radius of cable |
R18 |
|||||
|
Accessories |
Instruction manual and Mounting Bracket (E3JK-TR1[]-C only) |
|||||
|
Sensing method |
Retro-reflective |
Retro-reflective |
||||
|
Model |
E3JK-RR11-[] |
E3JK-RR13-[] |
E3JK-RR12-[] |
|||
|
Sensing distance |
7 m [100 mm]* (When using E39-R1), |
6 m [100 mm]* (When using E39-R1), |
||||
|
Standard sensing object |
Opaque: 75-mm dia. min. (When using E39-R1), Opaque: 100-mm dia. min. (When |
|||||
|
Differential travel |
- |
|||||
|
Directional angle |
1.5° min. |
|||||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
Red LED (624 nm) |
|||
|
Power supply voltage |
24 to 240 VDC ±10%, |
|||||
|
Power |
DC |
2 W max. |
||||
|
AC |
2 W max. |
|||||
|
Control output |
Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1), |
|||||
|
Protection circuits |
Mutual interference prevention function |
|||||
|
Life |
Mechanical |
50,000,000 times min. (switching frequency: 18,000 times/h) |
||||
|
Electrical |
100,000 times min. (switching frequency: 1,800 times/h) |
|||||
|
Response time |
20 ms max. |
|||||
|
Sensitivity adjustment |
One-turn adjuster |
|||||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
|||||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
|||||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
|||||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
|||||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
|||||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||
|
Malfunction |
100 m/s2 for 3 times each in X, Y, and Z directions |
|||||
|
Degree of protection |
IEC 60529 IP64 |
|||||
|
Connection method |
Pre-wired (standard length: 2 m) |
|||||
|
Weight (packed state) |
Approx. 180 g |
|||||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
||||
|
Lens/Display |
Methacrylic resin |
|||||
|
Adjuster |
POM |
|||||
|
Cable |
PVC |
|||||
|
Bending radius of cable |
R18 |
|||||
|
Accessories |
Instruction manual, Mounting Bracket (E3JK-RR1[]-C only), and Reflector (E3JK- |
|||||
*Values in parentheses indicate the minimum required distances between the Sensors and Reflectors.
|
Sensing method |
Diffuse-reflective |
||||
|
Model |
E3JK-DR11-[] |
E3JK-DR12-[] |
E3JK-DR13-[] |
E3JK-DR14-[] |
|
|
Sensing distance |
White paper |
White paper |
White paper |
White paper |
|
|
Standard sensing object |
- |
||||
|
Differential travel |
20% max. of sensing distance |
||||
|
Directional angle |
- |
||||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
|||
|
Power supply voltage |
24 to 240 VDC ±10%, |
||||
|
Power |
DC |
2 W max. |
|||
|
AC |
2 W max. |
||||
|
Control output |
Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1), |
||||
|
Protection circuits |
Mutual interference prevention function |
||||
|
Life |
Mechanical |
50,000,000 times min. (switching frequency: 18,000 times/h) |
|||
|
Electrical |
100,000 times min. (switching frequency: 1,800 times/h) |
||||
|
Response time |
20 ms max. |
||||
|
Sensitivity adjustment |
One-turn adjuster |
||||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
||||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
||||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
||||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
||||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
||||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
|||
|
Malfunction |
100 m/s2 for 3 times each in X, Y, and Z directions |
||||
|
Degree of protection |
IEC 60529 IP64 |
||||
|
Connection method |
Pre-wired (standard length: 2 m) |
||||
|
Weight (packed state) |
Approx. 180 g |
||||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
|||
|
Lens/Display |
Methacrylic resin |
||||
|
Adjuster |
POM |
||||
|
Cable |
PVC |
||||
|
Bending radius of cable |
R18 |
||||
|
Accessories |
Instruction manual and Mounting Bracket (E3JK-DR1[]-C only) |
||||
|
Sensing method |
Through-beam |
||||
|
Model |
NPN output |
E3JK-TN11 |
E3JK-TN12 |
E3JK-TN13 |
E3JK-TN14 |
|
PNP output |
E3JK-TP11 |
E3JK-TP12 |
E3JK-TP13 |
E3JK-TP14 |
|
|
Sensing distance |
40 m |
5 m |
40 m |
5 m |
|
|
Standard sensing object |
Opaque: 17-mm dia. min. |
||||
|
Differential travel |
- |
||||
|
Directional angle |
Both Emitter and Receiver 3° min. |
||||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
|||
|
Power supply voltage |
10 to 30 VDC, including ripple (p-p): 10% |
||||
|
Power |
DC |
40 mA max. (Emitter 25 mA max. Receiver 15 mA max.) |
|||
|
AC |
- |
||||
|
Control output |
Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., open-collector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable |
||||
|
Protection circuits |
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection |
||||
|
Life |
Mechanical |
- |
|||
|
Electrical |
- |
||||
|
Response time |
1 ms max. |
||||
|
Sensitivity adjustment |
One-turn adjuster Receiver (E3JK-T[][][]-D) only |
||||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
||||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
||||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
||||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
||||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
||||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
|||
|
Malfunction |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||
|
Degree of protection |
IEC 60529 IP64 |
||||
|
Connection method |
Pre-wired (standard length: 2 m) |
||||
|
Weight (packed state) |
Approx. 300 g |
||||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
|||
|
Lens/Display |
Methacrylic resin |
||||
|
Adjuster |
POM |
||||
|
Cable |
PVC |
||||
|
Bending radius of cable |
R18 |
||||
|
Accessories |
Instruction manual |
||||
|
Sensing method |
Retro-reflective (without MSR function) |
Retro-reflective |
||
|
Model |
NPN output |
E3JK-RN11 |
E3JK-RN13 |
E3JK-RN12 |
|
PNP output |
E3JK-RP11 |
E3JK-RP13 |
E3JK-RP12 |
|
|
Sensing distance |
7 m [100 mm]* (When using E39-R1), |
6 m [100 mm]* (When using E39-R1), |
||
|
Standard sensing object |
Opaque: 75-mm dia. min. |
|||
|
Differential travel |
- |
|||
|
Directional angle |
1.5° min. |
|||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
Red LED (624 nm) |
|
|
Power supply voltage |
10 to 30 VDC, including ripple (p-p): 10% |
|||
|
Power |
DC |
30 mA max. |
||
|
AC |
- |
|||
|
Control output |
Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., opencollector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable |
|||
|
Protection circuits |
Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention function, and Output reverse polarity protection |
|||
|
Life |
Mechanical |
- |
||
|
Electrical |
- |
|||
|
Response time |
1 ms max. |
|||
|
Sensitivity adjustment |
One-turn adjuster |
|||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
|||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
|||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
|||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
|||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
|||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
||
|
Malfunction |
500 m/s2 for 3 times each in X, Y, and Z directions |
|||
|
Degree of protection |
IEC 60529 IP64 |
|||
|
Connection method |
Pre-wired (standard length: 2 m) |
|||
|
Weight (packed state) |
Approx. 160 g |
|||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
||
|
Lens/Display |
Methacrylic resin |
|||
|
Adjuster |
POM |
|||
|
Cable |
PVC |
|||
|
Bending radius of cable |
R18 |
|||
|
Accessories |
Instruction manual |
|||
*Values in parentheses indicate the minimum required distances between the Sensors and Reflectors.
|
Sensing method |
Diffuse-reflective |
||||
|
Model |
NPN output |
E3JK-DN11 |
E3JK-DN12 |
E3JK-DN13 |
E3JK-DN14 |
|
PNP output |
E3JK-DP11 |
E3JK-DP12 |
E3JK-DP13 |
E3JK-DP14 |
|
|
Sensing distance |
White paper |
White paper |
White paper |
White paper |
|
|
Standard sensing object |
- |
||||
|
Differential travel |
20% max. of sensing distance |
||||
|
Directional angle |
- |
||||
|
Light source (wavelength) |
Red LED (624 nm) |
Infrared LED (850 nm) |
|||
|
Power supply voltage |
10 to 30 VDC, including ripple (p-p): 10% |
||||
|
Power |
DC |
30 mA max. |
|||
|
AC |
- |
||||
|
Control output |
Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., opencollector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable |
||||
|
Protection circuits |
Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention function, and Output reverse polarity protection |
||||
|
Life |
Mechanical |
- |
|||
|
Electrical |
- |
||||
|
Response time |
1 ms max. |
||||
|
Sensitivity adjustment |
One-turn adjuster |
||||
|
Ambient illumination |
Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max. |
||||
|
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) |
||||
|
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
||||
|
Insulation resistance |
20 MΩ min. at 500 VDC |
||||
|
Dielectric strength |
1,500 VAC, 50/60 Hz for 1 min |
||||
|
Vibration |
Destruction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
|
Malfunction |
10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
|
Shock |
Destruction |
500 m/s2 for 3 times each in X, Y, and Z directions |
|||
|
Malfunction |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||
|
Degree of protection |
IEC 60529 IP64 |
||||
|
Connection method |
Pre-wired (standard length: 2 m) |
||||
|
Weight (packed state) |
Approx. 160 g |
||||
|
Material |
Case |
ABS (Acrylonitrile Butadiene Styrene) |
|||
|
Lens/Display |
Methacrylic resin |
||||
|
Adjuster |
POM |
||||
|
Cable |
PVC |
||||
|
Bending radius of cable |
R18 |
||||
|
Accessories |
Instruction manual |
||||