Product Category

Smart Laser Sensors

E3NC

Ideal for Applications That Cannot Be Handled with Fiber Sensors or Photoelectric Sensors

Compact Laser Sensors: E3NC-L

Sensing method

Coaxial Retro-reflective with MSR function

Model

E3NC-LH03

E3NC-LH03+
 E39-P51

Light source (wavelength) *1

Visible semiconductor laser diode (660 nm), 1.35 mW (average output:
 315 μW) (JIS Class 1, IEC/EN Class 1, and FDA Class 1)

Sensing
 distance
 *2

Giga-power mode (GIGA)

8 m

0.5 m

Standard mode (Stnd)

6 m

High-speed mode (HS)

3.5 m

Super-high-speed mode
 (SHS)

2 m

Beam shape

Spot

Line

Beam size *3

Approx. 2 mm dia. at 1 m

Line length: Approx. 25 mm at
 250 mm
 Line length: Approx. 50 mm at
 500 mm

Differential distance *4

---

Indicators

OUT indicator (orange) and STABILITY indicator (green)

Ambient illumination (Receiver side)

Incandescent lamp: 10,000 lx max.,
 Sunlight: 20,000 lx max.

Ambient temperature range

Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
 condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Altitude

2,000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each
 in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC IP67 *5

Connecting method

Pre-wired connector (standard length: 2 m)

Materials

Sensor Head

Case

Polybutylene terephthalate (PBT)

Lens

Methacrylic resin (PMMA)

Cable

Vinyl chloride (PVC)

Lens
 Attachment

Case

---

ABS

Lens

---

Methacrylic resin (PMMA)

Weight (packed
 state/Sensor
 Head only)

Models with 2-m cable

Approx. 120 g/approx. 70 g

Models with 5-m cable

Approx. 180 g/approx. 130 g

Lens Attachment

---

Approx. 25 g/approx. 2 g

Accessories

Instruction Manual

Sensing method

Diffuse-reflective

Limited reflective

Model

E3NC-LH02

E3NC-LH02+
 E39-P52

E3NC-LH01

Light source (wavelength) *1

Visible semiconductor laser diode (660 nm), 1.35 mW (average output:
 315 μW) (JIS Class 1, IEC/EN Class 1, and FDA Class 1)

Sensing
 distance
 *2

Giga-power mode (GIGA)

1,200 mm

1,000 mm

70±15 mm

Standard mode (Stnd)

750 mm

600 mm

High-speed mode (HS)

250 mm

200 mm

Super-high-speed mode
 (SHS)

200 mm

150 mm

Beam shape

Spot

Line

Spot

Beam size *3

Approx. 0.8 mm dia. at
 300 mm

Line length: Approx. 45
 mm at 500 mm
 Line length: Approx. 100
 mm at 1,000 mm

Approx. 0.1 mm dia. at
 70 mm

Differential distance *4

10% of sensing distance max.

Indicators

OUT indicator (orange) and STABILITY indicator (green)

Ambient illumination (Receiver side)

Incandescent lamp: 10,000 lx max.,
 Sunlight: 20,000 lx max.

Ambient temperature range

Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
 condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Altitude

2,000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours
 each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC IP65 (E3NC-LH02: Applies only when adjuster is locked.) *5

Connecting method

Pre-wired connector (standard length: 2 m)

Materials

Sensor
 Head

Case

Polybutylene terephthalate (PBT)

Lens

Methacrylic resin (PMMA)

Cable

Vinyl chloride (PVC)

Lens
 Attachment

Case

---

ABS

---

Lens

---

Methacrylic resin
 (PMMA)

---

Weight (packed
 state/Sensor
 Head only)

Models with 2-m cable

Approx. 115 g/approx. 65 g

Models with 5-m cable

Approx. 175 g/approx. 125 g

Lens Attachment

---

Approx. 25 g/approx. 2 g

---

Accessories

Instruction Manual

1. These Sensors are classified as Class 1 laser devices under IEC 60825-1 and the regulations of Laser Notice No. 50 for
       FDA certification. CDRH (Center for Devices and Radiological Health) registration has been completed.
       E3NC-LH01, E3NC-LH02 (Accession Number: 1220690)
       E3NC-LH03 (Accession Number: 1320739)
 2. The values were measured using the OMRON standard sensing object (white paper) for the E3NC-LH01, E3NC-LH02,
       and E3NC-LH02 + E39-P52.
       The values for the E3NC-LH03, and E3NC-LH03 + E39-P51 apply when an E39-R21, E39-R22, E39-RS10, or
       E39-RS11 Reflector is used.
       Other Reflectors are not recommended.
3. Defined at the 1/e2 (13.5%) of the central intensity at the measurement distance.
       Measurement may be influenced if there is light leakage outside the defined region and the surroundings of the target
       object have a high reflectance in comparison to the target object.
 4. Measured at the rated sensing distance.
 5. The E39-P5[] contains a packing to prevent entry of foreign matter. The degree of protection between the
       E3NC-LH[][] and E39-P5[] is not specified.

Amplifier Units

Type

Standard models

Model for Sensor
 Communications Unit

NPN output

E3NC-LA21

E3NC-LA7

E3NC-LA24

E3NC-LA0

PNP output

E3NC-LA51

E3NC-LA9

E3NC-LA54

Connecting method

Pre-wired

Wire-saving
 Connector

M8
 Connector

Connector for Sensor
 Communications Unit

Inputs/
 outputs

Outputs

2 outputs

1 output

--- *1

External inputs

1 input

Power supply voltage *2

10 to 30 VDC, including 10% ripple (p-p)

Supplied from the
 connector through
 the Sensor
 Communications Unit

Power consumption *3

At Power Supply Voltage of 24 VDC
 Normal mode: 1,560mW max. (Current consumption: 65mA max.)
 Eco ON: 1,320 mW max. (Current consumption: 55 mA max.)
 Eco LO: 1,440 mW max. (Current consumption: 60 mA max.)

Control outputs *4

Load power supply voltage: 30 VDC max.,
 open-collector output
 Load current:
 Groups of 1 to 3 Amplifier Units: 100 mA max.,
 Groups of 4 to 30 Amplifier Units: 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

---

External inputs

Refer to *5.

---

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
 DPC indicator (green), and OUT selection indicator
 (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection,
 output short-circuit protection, and
 output reverse polarity protection

Power supply reverse
 polarity protection and
 output short-circuit
 protection

Response
 time

Super-high-speed mode (SHS) *6

Operate or reset: 80 μs

High-speed mode (HS)

Operate or reset: 250 μs

Standard mode (Stnd)

Operate or reset: 1 ms

Giga-power mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,
 or percentage tuning (-99% to +99%)), or manual adjustment.

Maximum connectable Units

30

With E3NW-ECT: 30 units *7
 With E3NW-CRT: 16 units
 With E3NW-CCL: 16 units

No. of Units
 for mutual
 interference
 prevention

Super-high-speed mode (SHS) *6

0

High-speed mode (HS)

2

Standard mode (Stnd)

2

Giga-power mode (GIGA)

4

Functions

Dynamic power control (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings *8

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode *9

Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Power tuning

Select from ON or OFF.

Output 1

Select from Normal Detection Mode or Area Detection Mode.

Output 2

Select from
 normal
 detection
 mode, alarm
 output mode,
 or error
 output mode.

---

Select from normal
 detection mode, alarm
 output mode, or error
 output mode.

External input

Select from input OFF, tuning, power tuning,
 laser OFF, zero reset, or bank switching.

---

Hysteresis width

Select from standard setting or user setting.

Ambient temperature range*

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C,
 Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C,
 Groups of 17 to 30 Amplifier Units: -25 to 40°C
 Storage: -30 to 70°C (with no icing or condensation)

Operating:
 Groups of 1 or 2 Amplifier
 Units: 0 to 55°C,
 Groups of 3 to 10 Amplifier
 Units: 0 to 50°C,
 Groups of 11 to 16 Amplifier
 Units: 0 to 45°C,
 Groups of 17 to 30 Amplifier
 Units: 0 to 40°C,
 Storage: -30 to 70°C
 (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Altitude

2,000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Insulation resistance

20 MΩ (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

150m/s2 for 3 times each in
 X, Y, and Z directions

Weight (packed state/Amplifier Unit only)

Approx. 115 g/
 approx. 75 g

Approx. 60 g/
 approx. 20 g

Approx. 65 g/approx. 25 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

Vinyl chloride (PVC)

Accessories

Instruction Manual

1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
       PLC operation via Communications Unit enables reading detected values and changing settings.
 2. Applicable Sensor Head is the series of E3NC-LH[][] (Input/Output 10-30V DC Class 2)
 3. At Power Supply Voltage of 10 to 30 VDC.
       Normal mode: 1,650 mW max. (Current consumption: 55 mA max. at 30 VDC, 115 mA max. at 10 VDC)
       Eco ON: 1,410 mW max. (Current consumption: 47 mA max. at 30 VDC, 95 mA max. at 10 VDC)
       Eco LO: 1,530 mW max. (Current consumption: 51 mA max. at 30 VDC, 105 mA max. at 10 VDC)
 4. The total for both outputs of a model with 2 outputs is 100 mA max.
       (Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA:2 V max.).
 5. The following details apply to the input. 


Contact input (relay or switch)

Non-contact input (transistor)

Input time*5-1

NPN

ON: Shorted to 0 V
 (Sourcing current: 1 mA max.).
 OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 1 mA max.)
 OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)

ON: 9 ms min.
 OFF: 20 ms min.

PNP

ON: Shorted to Vcc
 (Sinking current: 3 mA max.).
 OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
 OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
 6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
 7. When connected to an OMRON NJ-series Controller.
 8. The bank is not reset by the user reset function or saved by the user save function.
 9. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
 
 * When the number of connected units is 11 or more, the ambient temperature is less than 50°C. 

Accessories

Reflectors

Model

E39-R21

E39-R22

E39-RS10

E39-RS11

Ambient temperature

Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity

Operating/storage: 35% to 85% (with no condensation)

Vibration resistance
 (destruction)

10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 3 times each in X, Y, and Z directions

Degree of protection

IEC IP67 (E39-R21 and E39-R22 only)

Materials

Reflective surface: Methacrylic resin (PMMA)
 Back surface: Polybutylene terephthalate (PBT)

Methacrylic resin (PMMA)

Weight
 (packed state/
 Reflector only)

Approx. 30 g/
 approx. 5 g

Approx. 35 g/
 approx. 10 g

Approx. 35 g/
 approx. 10 g

Approx. 30 g/
 approx. 5 g

Accessories

Instruction manual

Ultra-compact CMOS Laser Sensor: E3NC-S

Sensor Heads

Sensing method

Distance-settable

Model

E3NC-SH250H

E3NC-SH250

E3NC-SH100

Light source (wavelength)*1

Visible semiconductor
 laser diode (660 nm),
 1 mW (average output:
 220 μW) (JIS Class 2,
 IEC/EN Class 2,
 and FDA Class 2)

Visible semiconductor laser diode (660 nm), 0.5 mW
 (average output: 100 μW) (JIS Class 1, IEC/EN Class 1,
 and FDA Class 1)

Measurement range

35 to 250 mm (display value: 350 to 2,500)

35 to 100 mm (display
 value: 350 to 1,000)

Standard detected level
 difference *2

35 to 180mm: 9 mm
 180 to 250 mm: 25 mm

35 to 50 mm: 1.5 mm
 50 to 100 mm: 3 mm

Beam size*3

Approx. 1 mm dia. at 250 mm

Approx. 0.5 mm dia. at 100 mm

Indicators

OUT indicator (orange), STABILITY indicator (green), and ST indicator (blue)

Ambient illumination
 (Receiver side)

Incandescent lamp:
 4,000 lx max.,
 Sunlight: 8,000 lx max.

Incandescent lamp:
 2,000 lx max.,
 Sunlight: 4,000 lx max.

Incandescent lamp:
 4,000 lx max.,
 Sunlight: 8,000 lx max.

Ambient temperature range

Operating: -10 to 50°C; Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Altitude

2,000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance
 (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 3 times each in X, Y, and Z directions

Degree of protection

IEC IP67

Connecting method

Pre-wired connector (Standard cable length: 2 m)

Materials

Case

Polybutylene terephthalate (PBT)

Lens

Methacrylic resin (PMMA)

Cable

Vinyl chloride (PVC)

Weight (packed state/
 Sensor Head only)

Approx. 125 g/approx. 75 g

Accessories

Instruction Manual, laser warning label (E3NC-SH250H only)

Note: Incorrect detection may occur outside the measurement range if the object has a high reflection factor.
 1. These Sensors are classified as Class 1 laser devices under IEC 60825-1 and the regulations of Laser Notice No. 50
       for FDA certification.
       CDRH (Center for Devices and Radiological Health) registration has been completed. (Accession Number: 1220691)
 2. The values were measured at the center of the sensing distance using OMRON’s standard sensing object
       (white ceramic).
 3. Beam size: Defined at the 1/e2 (13.5 %) of the central intensity at the measurement center distance.
       Measurement may be influenced if there is light leakage outside the defined region and the surroundings of the target
       object have a high reflectance in comparison to the target object.
       Also, when detecting a workpiece that is smaller than the beam size, a correct value may not be obtained. 

Amplifier Units

Type

Standard models

Model for Sensor
 Communications Unit

NPN output

E3NC-SA21

E3NC-SA7

E3NC-SA24

E3NC-SA0

PNP output

E3NC-SA51

E3NC-SA9

E3NC-SA54

Connecting method

Pre-wired

Wire-saving
 Connector

M8
 Connector

Connector for Sensor
 Communications Unit

Inputs/
 outputs

Outputs

2 outputs

1 output

--- *1

External inputs

1 input

Power supply voltage *2

10 to 30 VDC, including 10% ripple (p-p)

Supplied from the
 connector through
 the Sensor
 Communications Unit

Power consumption *3

At Power Supply Voltage of 24 VDC
 Normal mode: 1,920 mW max. (Current consumption: 80 mA max.)
 Eco ON: 1,680 mW max. (Current consumption: 70 mA max.)
 Eco LO: 1,800 mW max. (Current consumption: 75 mA max.)

Control outputs *4

Load power supply voltage: 30 VDC max.,
 open-collector output
 Load current:
 Groups of 1 to 3 Amplifier Units: 100 mA max.,
 Groups of 4 to 30 Amplifier Units: 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

――

External inputs

Refer to *5.

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
 ZERO indicator (green), and OUT selection indicator
 (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection,
 output short-circuit protection, and
 output reverse polarity protection

Power supply reverse
 polarity protection and
 output short-circuit
 protection

Response
 time

Super-high-speed mode (SHS) *6

Operate or reset: 1.5 ms

High-speed mode (HS)

Operate or reset: 5 ms

Standard mode (Stnd)

Operate or reset: 10 ms

Giga-power mode (GIGA)

Operate or reset: 50 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, 1-point tuning, tuning without workpiece,
 2-point area tuning, 1-point area tuning, or area tuning without workpiece),
 or manual adjustment

Maximum connectable Units

30

With E3NW-ECT: 30 units *7
 With E3NW-CRT: 16 units
 With E3NW-CCL: 16 units

No. of Units
 for mutual
 interference
 prevention

Super-high-speed mode (SHS) *6

0

High-speed mode (HS)

2

Standard mode (Stnd)

2

Giga-power mode (GIGA)

2

Functions

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings *8

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode *9

Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Output 1

Select from Normal detection mode, Area detection mode, or hold mode.

Output 2

Select from
 Normal
 detection
 mode or Error
 output mode.

---

Select from Normal
 detection mode or Error
 output mode.

External input

Select from input OFF, tuning, laser OFF,
 zero reset, or bank switching.

――

Keep function *10

Select from ON or OFF.

Background suppression *11

Select from ON or OFF.

Hysteresis width

Select from standard setting or user setting.

Ambient temperature range*

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C,
 Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C,
 Groups of 17 to 30 Amplifier Units: -25 to 40°C
 Storage: -30 to 70°C (with no icing or condensation)

Operating:
 Groups of 1 or 2 Amplifier
 Units: 0 to 55°C,
 Groups of 3 to 10 Amplifier
 Units: 0 to 50°C,
 Groups of 11 to 16 Amplifier
 Units: 0 to 45°C,
 Groups of 17 to 30 Amplifier
 Units: 0 to 40°C
 Storage: -30 to 70°C
 (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 MΩ (at 500 VDC)

Altitude

2,000 m max.

Installation environment

Pollution degree 3 (as per IEC 60947-1)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

150 m/s2 for 3 times each
 in X, Y, and Z directions

Weight (packed state/Amplifier Unit only)

Approx. 115 g/
 approx. 75 g

Approx. 60 g/
 approx. 20 g

Approx. 65 g/approx. 25 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

Vinyl chloride (PVC)

Accessories

Instruction Manual

1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
       PLC operation via Communications Unit enables reading detected values and changing settings.
 2. Applicable Sensor Head is the series of E3NC-SH[][] (Input/Output 10-30V DC Class 2).
 3. At Power Supply Voltage of 10 to 30 VDC.
       Normal mode: 2,250 mW max. (Current consumption: 75 mA max. at 30 VDC, 145 mA max. at 10 VDC)
       Eco ON: 2,010 mW max. (Current consumption: 67 mA max. at 30 VDC, 125 mA max. at 10 VDC)
       Eco LO: 2,130 mW max. (Current consumption: 71 mA max. at 30 VDC, 135 mA max. at 10 VDC)
 4. The total for both outputs of a model with 2 outputs is 100 mA max.
       (Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA: 2 V max.).
 5. The following details apply to the input. 


Contact input (relay or switch)

Non-contact input (transistor)

Input time*5-1

NPN

ON: Shorted to 0 V
 (Sourcing current: 1 mA max.).
 OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 1 mA max.)
 OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)

ON: 9 ms min.
 OFF: 20 ms min.

PNP

ON: Shorted to Vcc
 (Sinking current: 3 mA max.).
 OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
 OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) input is selected.
 6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
 7. When connected to an OMRON NJ-series Controller.
 8. The bank is not reset by the user reset function or saved by the user save function.
 9. Eco LO is supported for Amplifier Units manufactured in August 2014 or later.
 10. The output for a measurement error is set.
       ON: The value of the output from before the measurement error is retained.
       OFF: The output is turned OFF when a measurement error occurs.
 11. Only the sensing object is detected when tuning.
 
 When the number of connected units is 11 or more, the ambient temperature is less than 50°C.