Color Fiber Amplifier Unit
E3NX-FA
The Advanced Fiber Amplifier Units That Handles On-site Needs
Standard models/ Advanced models/ Infrared models
Type |
Standard models |
||||||
NPN output |
E3NX-FA11 |
E3NX-FA6 |
E3NX-FA11-5 *1 |
||||
PNP output |
E3NX-FA41 |
E3NX-FA8 |
--- |
||||
Connecting method |
Pre-wired |
Wire-saving Connector |
Pre-wired |
||||
Inputs/ |
Outputs |
1 output |
|||||
External inputs |
--- |
||||||
Light source (wavelength) |
Red, 4-element LED (625 nm) |
||||||
Power supply voltage |
10 to 30 VDC, including 10% ripple (p-p) |
||||||
Power consumption *2 |
At Power supply voltage of 24 VDC |
||||||
Control output |
Load power supply voltage: 30 VDC max., open-collector output |
||||||
External inputs |
--- |
||||||
Indicators |
7-segment displays (Sub digital display: green, Main digital display: white) |
||||||
Protection circuits |
Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
||||||
Response |
Super-high-speed mode (SHS) |
Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs |
|||||
High-speed mode (HS) |
Operate or reset: 250 μs |
||||||
Standard mode (Stnd) |
Operate or reset: 1 ms |
||||||
Giga-power mode (GIGA) |
Operate or reset: 16 ms |
||||||
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment |
||||||
Maximum connectable Units |
30 |
||||||
No. of |
Super-high-speed mode (SHS) |
0 |
|||||
High-speed mode (HS) |
10 |
||||||
Standard mode (Stnd) |
10 |
||||||
Giga-power mode (GIGA) |
10 |
||||||
Functions |
Automatic power control |
Always enabled. |
|||||
Dynamic power control |
Provided |
||||||
Timer |
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay |
||||||
Zero reset |
Negative values can be displayed. (Threshold value is shifted.) |
||||||
Resetting settings *5 |
Select from initial reset (factory defaults) or user reset (saved settings). |
||||||
Eco mode *6 |
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
||||||
Bank switching |
Select from banks 1 to 4. |
||||||
Power tuning |
Select from ON, OFF or Execution on power-up. |
||||||
Output 1 |
Select from normal detection mode, area detection mode or differential detection mode. |
||||||
Output 2 |
--- |
||||||
External input |
--- |
||||||
Hysteresis width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. |
||||||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. |
||||||
Ambient temperature range *7 |
Operating: |
||||||
Ambient humidity range |
Operating and storage: 35 to 85% (with no condensation) |
||||||
Altitude |
2,000 m max. |
||||||
Installation environment |
Pollution degree 3 |
||||||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min |
||||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||||
Weight (packed state/Sensor only) |
Approx. 115 g/ |
Approx. 60 g/ |
Approx. 115 g/ |
||||
Materials |
Case |
Polycarbonate (PC) |
|||||
Cover |
Polycarbonate (PC) |
||||||
Cable |
PVC |
||||||
Accessories |
Instruction Manual |
||||||
Type |
Advanced models |
||||||
NPN output |
E3NX-FA21 |
E3NX-FA7 |
E3NX-FA7TW |
E3NX-FA24 |
--- |
||
PNP output |
E3NX-FA51 |
E3NX-FA9 |
E3NX-FA9TW |
E3NX-FA54 |
E3NX-FA54TW |
||
Connecting method |
Pre-wired |
Wire-saving Connector |
M8 Connector |
||||
Inputs/ |
Outputs |
2 outputs |
1 output |
2 outputs |
1 output |
2 outputs |
|
External inputs |
1 input |
1 input |
--- |
1 input |
--- |
||
Light source (wavelength) |
Red, 4-element LED (625 nm) |
||||||
Power supply voltage |
10 to 30 VDC, including 10% ripple (p-p) |
||||||
Power consumption *2 |
At Power supply voltage of 24 VDC |
||||||
Control output |
Load power supply voltage: 30 VDC max., open-collector output |
||||||
External inputs |
Refer to *3. |
--- |
Refer to *3. |
--- |
|||
Indicators |
7-segment displays (Sub digital display: green, Main digital display: white) |
||||||
Protection circuits |
Power supply reverse polarity protection, output short-circuit protection, |
||||||
Response |
Super-high-speed mode (SHS) |
Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs |
|||||
High-speed mode (HS) |
Operate or reset: 250 μs |
||||||
Standard mode (Stnd) |
Operate or reset: 1 ms |
||||||
Giga-power mode (GIGA) |
Operate or reset: 16 ms |
||||||
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment |
||||||
Maximum connectable Units |
30 |
||||||
No. of |
Super-high-speed mode (SHS) |
0 |
|||||
High-speed mode (HS) |
10 |
||||||
Standard mode (Stnd) |
10 |
||||||
Giga-power mode (GIGA) |
10 |
||||||
Functions |
Automatic power control |
Always enabled. |
|||||
Dynamic power control |
Provided |
||||||
Timer |
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay |
||||||
Zero reset |
Negative values can be displayed. (Threshold value is shifted.) |
||||||
Resetting settings *5 |
Select from initial reset (factory defaults) or user reset (saved settings). |
||||||
Eco mode *6 |
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
||||||
Bank switching |
Select from banks 1 to 4. |
||||||
Power tuning |
Select from ON, OFF or Execution on power-up. |
||||||
Output 1 |
Select from normal detection mode, area detection mode or differential detection mode. |
||||||
Output 2 |
Select from |
--- |
Select from |
--- |
Select from |
||
External input |
Select from input OFF, |
--- |
Select |
--- |
|||
Hysteresis width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. |
||||||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. |
||||||
Ambient temperature range *7 |
Operating: |
||||||
Ambient humidity range |
Operating and storage: 35 to 85% (with no condensation) |
||||||
Altitude |
2,000 m max. |
||||||
Installation environment |
Pollution degree 3 |
||||||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min |
||||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions |
||||||
Weight (packed state/Sensor only) |
Approx. 115 g/ |
Approx. 60g/approx. 20g |
Approx. 65 g/ |
||||
Materials |
Case |
Polycarbonate (PC) |
|||||
Cover |
Polycarbonate (PC) |
||||||
Cable |
PVC |
||||||
Accessories |
Instruction Manual |
||||||
Type |
Infrared models |
||
NPN output |
E3NX-FAH11 |
E3NX-FAH6 |
|
PNP output |
E3NX-FAH41 |
E3NX-FAH8 |
|
Connecting method |
Pre-wired |
Wire-saving |
|
Inputs/ |
Outputs |
1 outputs |
|
External inputs |
--- |
||
Light source (wavelength) |
Infrared LED (870nm) |
||
Power supply voltage |
10 to 30 VDC, including 10% ripple (p-p) |
||
Power consumption *2 |
At Power supply voltage of 24 VDC |
||
Control output |
Load power supply voltage: 30 VDC max., open-collector output |
||
External inputs |
--- |
||
Indicators |
7-segment displays (Sub digital display: green, Main digital display: white) |
||
Protection circuits |
Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
||
Response |
Super-high-speed mode (SHS) |
Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs |
|
High-speed mode (HS) |
Operate or reset: 250 μs |
||
Standard mode (Stnd) |
Operate or reset: 1 ms |
||
Giga-power mode (GIGA) |
Operate or reset: 16 ms |
||
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment |
||
Maximum connectable Units |
30 |
||
No. of |
Super-high-speed mode (SHS) |
0 |
|
High-speed mode (HS) |
10 |
||
Standard mode (Stnd) |
10 |
||
Giga-power mode (GIGA) |
10 |
||
Functions |
Automatic power control |
Always enabled. |
|
Dynamic power control |
Provided |
||
Timer |
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay |
||
Zero reset |
Negative values can be displayed. (Threshold value is shifted.) |
||
Resetting settings *5 |
Select from initial reset (factory defaults) or user reset (saved settings). |
||
Eco mode *6 |
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). |
||
Bank switching |
Select from banks 1 to 4. |
||
Power tuning |
Select from ON or OFF. |
||
Output 1 |
Select from normal detection mode or area detection mode. |
||
Output 2 |
--- |
||
External input |
--- |
||
Hysteresis width |
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. |
||
Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. |
||
Ambient temperature range *7 |
Operating: |
||
Ambient humidity range |
Operating and storage: 35 to 85% (with no condensation) |
||
Altitude |
2,000 m max. |
||
Installation environment |
Pollution degree 3 |
||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min |
||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||
Shock resistance (destruction) |
500 m/s2 for 3 times each in X, Y, and Z directions |
||
Weight (packed state/Sensor only) |
Approx. 115 g/approx. 75 g |
Approx. 60g/approx. 20g |
|
Materials |
Case |
Polycarbonate (PC) |
|
Cover |
Polycarbonate (PC) |
||
Cable |
PVC |
||
Accessories |
Instruction Manual |
1. This type can prevent mutual interference for two units in the SHS2 mode.
2. At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode : 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC)
Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC)
Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC)
Advanced Models:
Normal mode : 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC)
Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC)
Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC)
Infrared models:
Normal mode : 1,260 mW max. (Current consumption: 42 mA max. at 30 VDC, 80 mA max. at 10 VDC)
Eco function ON : 1,050 mW max. (Current consumption: 35 mA max. at 30 VDC, 60 mA max. at 10 VDC)
Eco function LO : 1,140 mW max. (Current consumption: 38 mA max. at 30 VDC, 70 mA max. at 10 VDC)
3. The following details apply to the input.
Contact input (relay or switch) |
Non-contact input (transistor) |
Input time*3-1 |
|
NPN |
ON: Shorted to 0 V (Sourcing current: 1 mA |
ON: 1.5 V max. (Sourcing current: 1 mA max.) |
ON: 9 ms min. |
PNP |
ON: Shorted to Vcc (Sinking current: 3 mA |
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA |
3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC. Check the mutual interference prevention unit count and response speed of each model.
5. The bank is not reset by the user reset function or saved by the user save function.
6. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Analog output models/ Model for Sensor Communications Unit
Type |
Analog output |
Model for Sensor Communications Unit |
|||
NPN output |
E3NX-FA11AN |
E3NX-FA10 |
E3NX-FA0 |
E3NX-FAH0 |
|
PNP output |
E3NX-FA41AN |
E3NX-FA40 |
|||
Connecting method |
Pre-wired |
Connector for |
Connector for Sensor |
||
Inputs/ |
Outputs |
2 outputs |
1 outputs |
--- *1 |
|
External |
--- |
--- |
|||
Light source |
Red, 4-element LED (625 nm) |
Infrared LED (870nm) |
|||
Power supply voltage |
10 to 30 VDC, including |
Supplied from the connector through the communication units. |
|||
Power consumption *2 |
At Power supply |
At Power supply voltage of 24 |
At Power supply voltage |
||
Control output |
Load power supply voltage: |
--- |
|||
Analog output |
Voltage output: 1-5 VDC |
--- |
|||
Indicators |
7-segment displays (Sub digital display: green, Main digital display: white) |
||||
Protection circuits |
Power supply reverse polarity protection, |
Power supply reverse polarity |
|||
Control |
Super-high- |
Operate or reset: |
Operate or reset: 32 μs |
||
High-speed |
Operate or reset: |
Operate or reset: 250 μs |
|||
Standard |
Operate or reset: |
Operate or reset: 1 ms |
|||
Giga-power |
Operate or reset: |
Operate or reset: 16 ms |
|||
Sensitivity adjustment |
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, |
||||
Maximum connectable Units |
30 |
16 |
With E3NW-ECT: 30 units |
||
No. of |
Super-high- |
0 (The mutual interference prevention function is disabled if the detection mode is set to |
|||
High-speed |
10 |
||||
Standard |
10 |
||||
Giga-power |
10 |
||||
Func- |
Automatic |
Always enabled. |
|||
Dynamic |
Provided |
||||
Timer |
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: |
||||
Zero reset |
Negative values can be displayed. (Threshold value is shifted.) |
||||
Resetting |
Select from initial reset (factory defaults) or user reset (saved settings). |
||||
Eco mode |
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display |
||||
Bank |
Select from banks 1 to 4. |
||||
Sensor OFF |
--- |
Select from |
--- |
||
Power |
Select from ON or OFF. |
||||
Output 1 |
Select from normal detection mode, area detection mode or differential detection mode |
||||
Output 2 |
Select from Analog |
--- |
Select from normal detection mode, |
||
Hysteresis |
Select from standard setting or user setting. For a user setting, the hysteresis width can |
||||
Ambient illumination |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. |
||||
Ambient temperature |
Operating: |
Operating: |
Operating: |
||
Ambient humidity range |
Operating and storage: 35 to 85% (with no condensation) within the surrounding air |
||||
Altitude |
2,000 m max. |
||||
Installation environment |
Pollution degree 3 |
||||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min |
||||
Vibration resistance |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance |
500 m/s2 for 3 times |
150 m/s2 for 3 times each in X, Y, and Z directions |
|||
Weight (packed state/ |
Approx. 115 g/ |
Approx. 95 g/ |
Approx. 65 g/ |
Approx. 65 g/ |
|
Materials |
Case |
Polycarbonate (PC) |
|||
Cover |
Polycarbonate (PC) |
||||
Cable |
PVC |
||||
Accessories |
Instruction Manual |
1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
2. At Power supply voltage of 10 to 30 VDC
Analog output models:
Normal mode : 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
3. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
4. The bank is not reset by the user reset function or saved by the user save function.
5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Sensing Distances
Standard models/ Advanced models/ Analog output models
Threaded Models
Sensing |
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
||||
Through-beam |
Right-angle |
M4 |
E32-T11N 2M |
3,000 |
1,500 |
1,050 |
280 |
E32-LT11N 2M |
4,000*1 |
4,000*1 |
3,450 |
920 |
|||
Straight |
E32-T11R 2M |
3,000 |
1,500 |
1,050 |
280 |
||
E32-LT11 2M |
4,000*1 |
4,000*1 |
4,000*1 |
1,080 |
|||
E32-LT11R 2M |
4,000*1 |
4,000*1 |
3,450 |
920 |
|||
Reflective |
Right-angle |
M3 |
E32-C31N 2M |
160 |
75 |
69 |
14 |
E32-C21N 2M |
440 |
190 |
130 |
39 |
|||
M4 |
E32-D21N 2M |
1,260 |
520 |
360 |
100 |
||
M6 |
E32-C11N 2M |
1,170 |
520 |
480 |
100 |
||
E32-LD11N 2M |
1,260 |
520 |
360 |
100 |
|||
Straight |
M3 |
E32-D21R 2M |
210 |
90 |
60 |
16 |
|
E32-C31 2M |
490 |
220 |
150 |
44 |
|||
E32-C31M 1M |
|||||||
M4 |
E32-D211R 2M |
210 |
90 |
60 |
16 |
||
M6 |
E32-D11R 2M |
1,260 |
520 |
360 |
100 |
||
E32-CC200 2M |
2,100 |
900 |
600 |
180 |
|||
E32-LD11 2M |
1,290 |
540 |
370 |
110 |
|||
E32-LD11R 2M |
1,260 |
520 |
360 |
100 |
Cylindrical Models
Sensing |
Size |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through- |
1 dia. |
Top-view |
E32-T223R 2M |
670 |
370 |
220 |
60 |
1.5 dia. |
E32-T22B 2M |
1,020 |
600 |
330 |
90 |
||
3 dia. |
E32-T12R 2M |
3,000 |
1,500 |
1,050 |
280 |
||
Side-view |
E32-T14LR 2M |
1,120 |
670 |
390 |
100 |
||
Reflective |
1.5 dia. |
Top-view |
E32-D22B 2M |
210 |
90 |
60 |
16 |
1.5 dia. + 0.5 dia. |
E32-D43M 1M |
42 |
18 |
12 |
4 |
||
3 dia. |
E32-D22R 2M |
210 |
90 |
60 |
16 |
||
E32-D221B 2M |
450 |
210 |
130 |
40 |
|||
E32-D32L 2M |
1,050 |
450 |
300 |
90 |
|||
3 dia. + 0.8 dia. |
E32-D33 2M |
100 |
45 |
30 |
8 |
Flat Models
Sensing |
Sensing direction |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
Top-view |
E32-T15XR 2M |
3,000 |
1,500 |
1,050 |
280 |
Side-view |
E32-T15YR 2M |
1,120 |
670 |
390 |
100 |
|
Flat-view |
E32-T15ZR 2M |
|||||
Reflective |
Top-view |
E32-D15XR 2M |
1,260 |
520 |
360 |
100 |
Side-view |
E32-D15YR 2M |
300 |
150 |
78 |
24 |
|
Flat-view |
E32-D15ZR 2M |
Sleeve Models
Sensing |
Sensing direction |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
Side-view |
E32-T24R 2M |
250 |
150 |
75 |
20 |
E32-T24E 2M |
670 |
370 |
220 |
60 |
||
Top-view |
E32-T33 1M |
220 |
130 |
75 |
20 |
|
E32-T21-S1 2M |
760 |
450 |
250 |
68 |
||
E32-TC200BR 2M |
3,000 |
1,500 |
1,050 |
280 |
||
Reflective |
Side-view |
E32-D24R 2M |
100 |
45 |
30 |
8 |
E32-D24-S2 2M |
180 |
79 |
67 |
14 |
||
Top-view |
E32-D43M 1M |
42 |
18 |
12 |
4 |
|
E32-D331 2M |
21 |
9 |
6 |
2 |
||
E32-D33 2M |
100 |
45 |
30 |
8 |
||
E32-D32-S1 0.5M |
94 |
40 |
27 |
7 |
||
E32-D31-S1 0.5M |
||||||
E32-DC200F4R 2M |
210 |
90 |
60 |
16 |
||
E32-D22-S1 2M |
370 |
160 |
100 |
30 |
||
E32-D21-S3 2M |
||||||
E32-DC200BR 2M |
1,260 |
520 |
360 |
100 |
||
E32-D25-S3 2M |
370 |
160 |
100 |
30 |
Small-spot, Reflective Models
Type |
Spot |
Center |
Models |
Sensing distance (mm) |
|||
Giga |
Standard |
High-speed |
Super-high- |
||||
Variable |
0.1 to 0.6 dia. |
6 to 15 |
E32-C42 1M + E39-F3A |
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. |
|||
0.3 to 1.6 dia. |
10 to 30 |
E32-C42 1M + E39-F17 |
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. |
||||
Parallel |
4 dia. |
0 to 20 |
E32-C31 2M + E39-F3C |
Spot diameter of 4 mm max. at 0 to 20 mm. |
|||
E32-C31N 2M + E39-F3C |
|||||||
Integrated |
0.1 dia. |
5 |
E32-C42S 1M |
Spot diameter of 0.1 mm at 5 mm. |
|||
6 dia. |
50 |
E32-L15 2M |
Spot diameter of 6 mm at 50 mm. |
||||
Small- |
0.1 dia. |
7 |
E32-C41 1M + E39-F3A-5 |
Spot diameter of 0.1 mm at 7 mm. |
|||
0.5 dia. |
E32-C31 2M + E39-F3A-5 |
Spot diameter of 0.5 mm at 7 mm. |
|||||
E32-C31N 2M + E39-F3A-5 |
|||||||
0.2 dia. |
17 |
E32-C41 1M + E39-F3B |
Spot diameter of 0.2 mm at 17 mm. |
||||
0.5 dia. |
E32-C31 2M + E39-F3B |
Spot diameter of 0.5 mm at 17 mm. |
|||||
E32-C31N 2M + E39-F3B |
|||||||
3 dia. |
50 |
E32-CC200 2M + E39-F18 |
Spot diameter of 3 mm at 50 mm. |
||||
E32-C11N 2M + E39-F18 |
High-power Beam Models
Type |
Sensing |
Center |
Models |
Sensing distance (mm) |
|||
Giga |
Standard |
High- |
Super- |
||||
Through-beam |
Right-angle |
15° |
E32-LT11N 2M |
4,000*2 |
4,000*2 |
3,450 |
920 |
Top-view |
10° |
E32-T17L 10M |
20,000 *1 |
20,000 *1 |
20,000 *1 |
8,000 |
|
15° |
E32-LT11 2M |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,080 |
||
E32-LT11R 2M |
4,000 *2 |
4,000 *2 |
3,450 |
920 |
|||
Side-view |
30° |
E32-T14 2M |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
|
Through-beam |
Right-angle |
12° |
E32-T11N 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
2,000 |
6° |
E32-T11N 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,600 |
||
Top-view |
12° |
E32-T11R 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
2,000 |
|
6° |
E32-T11R 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,600 |
||
Side-view |
60° |
E32-T11R 2M + E39-F2 |
2,170 |
1,200 |
750 |
200 |
|
Top-view |
12° |
E32-T11 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,860 |
|
6° |
E32-T11 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Side-view |
60° |
E32-T11 2M + E39-F2 |
3,450 |
1,980 |
1,290 |
320 |
|
Top-view |
12° |
E32-T51R 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,500 |
|
6° |
E32-T51R 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Side-view |
60° |
E32-T51R 2M + E39-F2 |
2,100 |
1,080 |
750 |
200 |
|
Top-view |
12° |
E32-T81R-S 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,000 |
|
6° |
E32-T81R-S 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
||
Side-view |
60° |
E32-T81R-S 2M + E39-F2 |
1,500 |
820 |
540 |
140 |
|
Top-view |
12° |
E32-T61-S 2M + E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
|
6° |
E32-T61-S 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,100 |
||
Side-view |
60° |
E32-T61-S 2M + E39-F2 |
2,520 |
1,350 |
900 |
240 |
|
Top-view |
12° |
E32-T51 2M + E39-F1-33 |
4,000 *2 |
4,000 *2 |
3,450 |
1,400 |
|
6° |
E32-T51 2M + E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Reflective |
Top-view |
4° |
E32-D16 2M |
40 to |
40 to |
40 to |
40 to 720 |
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing |
Sensing |
Aperture |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through-beam |
Side-view |
1.5° |
E32-A03 2M |
4,000 *1 |
2,670 |
1,800 |
500 |
E32-A03-1 2M |
|||||||
3.4° |
E32-A04 2M |
1,920 |
1,020 |
670 |
200 |
||
4° |
E32-T24SR 2M |
4,000 *1 |
3,300 |
2,190 |
580 |
||
E32-T24S 2M |
4,000 *1 |
3,900 |
2,610 |
700 |
|||
E32-T22S 2M |
4,000 *1 |
4,000 *1 |
3,750 |
1,000 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high-speed |
|||
Limited- |
Flat-view |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||
E32-L24S 2M |
0 to 4 |
|||||
Side-view |
E32-L25L 2M |
5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective Models)
Sensing |
Feature |
Size |
Models |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Retro- |
Film detection |
M3 |
E32-C31 2M + E39-F3R + |
370 |
300 |
--- |
|
Square |
--- |
E32-R16 5M |
150 to 1,500 |
||||
Threaded |
M6 |
E32-R21 2M |
10 to 370 |
10 to 250 |
|||
Hex-shaped |
E32-LR11NP 2M + |
2,020 |
1,800 |
1,500 |
550 |
Transparent Object Detection (Limited-reflective Models)
Sensing |
Feature |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga |
Standard |
High-speed |
Super-high- |
||||
Limited- |
Small size |
Flat-view |
E32-L24S 2M |
0 to 4 |
|||
Standard |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||||
Glass substrate |
E32-A08 2M |
10 to 20 |
--- |
||||
Standard/long-distance |
E32-A12 2M |
12 to 30 |
--- |
||||
Side-view form |
Side-view |
E32-L25L 2M |
5.4 to 9 (center 7.2) |
||||
Glass substrate |
Top-view |
E32-A09 2M |
15 to 38 |
--- |
Chemical-resistant, Oil-resistant Models
Sensing |
Type |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through- |
Oil-resistant |
Right-angle |
E32-T11NF 2M |
4,000 *1 |
4,000 *1 |
4,000 *1 |
2,200 |
Chemical/ |
Top-view |
E32-T12F 2M |
4,000 *1 |
4,000 *1 |
4,000 *1 |
1,600 |
|
E32-T11F 2M |
4,000 *1 |
4,000 *1 |
3,900 |
1,000 |
|||
Side-view |
E32-T14F 2M |
2,100 |
1,200 |
750 |
200 |
||
Chemical/ |
Top-view |
E32-T51F 2M |
4,000 *1 |
4,000 *1 |
2,700 |
700 |
|
Reflective |
Semiconductors: |
Top-view |
E32-L11FP 5M |
8 to 20 mm from tip of lens (Recommended sensing |
|||
Semiconductors: |
E32-L11FS 5M |
8 to 20 mm from tip of lens (Recommended sensing |
|||||
Chemical/ |
E32-D12F 2M |
--- *2 |
280 |
190 |
60 |
||
Chemical- |
E32-D11U 2M |
1,260 |
520 |
360 |
100 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high-speed |
|||
Through-beam |
1.5 dia. |
E32-T22B 2M |
1,020 |
600 |
330 |
90 |
M3 |
E32-T21 2M |
|||||
M4 |
E32-T11 2M |
3,750 |
2,020 |
1,350 |
360 |
|
Square |
32-T25XB 2M |
750 |
450 |
250 |
70 |
|
Reflective |
1.5 dia. |
E32-D22B 2M |
210 |
90 |
60 |
16 |
M3 |
E32-D21 2M |
|||||
3 dia. |
E32-D221B 2M |
450 |
210 |
130 |
40 |
|
M4 |
E32-D21B 2M |
|||||
M6 |
E32-D11 2M |
1,260 |
520 |
360 |
100 |
|
Square |
E32-D25XB 2M |
360 |
150 |
90 |
30 |
Heat-resistant Models
Sensing |
Heat-resistant |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
|||
Through-beam |
100°C |
E32-T51R 2M |
2,400 |
1,200 |
840 |
225 |
150°C |
E32-T51 2M |
4,000 *1 |
2,250 |
1,500 |
400 |
|
200°C |
E32-T81R-S 2M |
1,500 |
820 |
540 |
140 |
|
350°C |
E32-T61-S 2M |
2,520 |
1,350 |
900 |
240 |
|
Reflective |
100°C |
E32-D51R 2M |
1,000 |
420 |
280 |
80 |
150°C |
E32-D51 2M |
1,680 |
670 |
480 |
144 |
|
200°C |
E32-D81R-S 2M |
630 |
270 |
180 |
54 |
|
300°C |
E32-A08H2 2M |
10 to 20 |
--- |
|||
E32-A09H2 2M |
20 to 30 (center 25) |
--- |
||||
350°C |
E32-D611-S 2M |
630 |
270 |
180 |
54 |
|
E32-D61-S 2M |
||||||
400°C |
E32-D73-S 2M |
420 |
180 |
120 |
36 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Area Detection Models
Sensing |
Type |
Sensing width |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through-beam |
Area |
11 mm |
E32-T16PR 2M |
4,000 *1 |
2,550 |
1,680 |
440 |
E32-T16JR 2M |
4,000 *1 |
2,250 |
1,440 |
380 |
|||
30 mm |
E32-T16WR 2M |
4,000 *1 |
3,900 |
2,550 |
680 |
||
Reflective |
Array |
11 mm |
E32-D36P1 2M |
1,050 |
450 |
300 |
90 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing |
Tube |
Feature |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Tube- |
3.2, 6.4, or |
Stable |
E32-A01 5M |
Applicable tube: Transparent tube with a diameter of 3.2, |
|||
8 to 10 dia |
Mounting at |
E32-L25T 2M |
Applicable tube: Transparent tube with a diameter of 8 to |
||||
No |
Large tubes |
E32-D36T 5M |
Applicable tube: Transparent tube (no restrictions on |
||||
Liquid contact |
--- |
--- |
E32-D82F1 4M |
Liquid-contact type |
Vacuum-resistant Models
Sensing |
Heat-resistant |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
120 °C |
E32-T51V 1M |
1,080 |
600 |
390 |
100 |
E32-T51V 1M + E39-F1V |
2,000 *1 |
2,000 *1 |
2,000 *1 |
520 |
||
200 °C |
E32-T84SV 1M |
2,000*1 |
1,420 |
960 |
260 |
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing |
Application |
Operating |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Limited- |
Glass presence |
70°C |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||
E32-A08 2M |
10 to 20 |
--- |
|||||
Glass substrate |
300°C |
E32-A08H2 3M |
|||||
70°C |
E32-A12 2M |
12 to 30 |
--- |
||||
Glass substrate |
E32-A09 2M |
15 to 38 |
--- |
||||
300°C |
E32-A09H2 2M |
20 to 30 (center 25) |
--- |
||||
Wet processes: |
60°C |
E32-L11FP 5M |
8 to 20 mm from tip of lens (Recommended sensing |
||||
Wet process: |
85°C |
E32-L11FS 5M |
8 to 20 mm from tip of lens (Recommended sensing |
||||
Through- |
Wafer mapping |
70°C |
E32-A03 2M |
4,000 *1 |
2,670 |
1,800 |
500 |
E32-A03-1 2M |
|||||||
E32-A04 2M |
1,920 |
1,020 |
670 |
200 |
|||
E32-T24SR 2M |
4,000 *1 |
3,300 |
2,190 |
580 |
|||
E32-T24S 2M |
4,000 *1 |
3,900 |
2,610 |
700 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Infrared models
Threaded Models
Sensing |
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
||||
Through- |
Right-angle |
M4 |
E32-T11N 2M |
280 |
190 |
130 |
55 |
Straight |
E32-T11R 2M |
||||||
Reflective |
Straight |
M3 |
E32-C31 2M |
50 |
37 |
25 |
8.5 |
M6 |
E32-D11R 2M |
120 |
90 |
60 |
21 |
||
E32-CC200 2M |
200 |
150 |
100 |
35 |
Cylindrical Models
Sensing |
Size |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
||||
Through- |
3 dia. |
Top-view |
E32-T12R 2M |
280 |
190 |
130 |
55 |
Side-view |
E32-T14LR 2M |
100 |
75 |
80 |
21 |
||
Reflective |
3 dia. |
Top-view |
E32-D32L 2M |
100 |
75 |
50 |
17 |
Flat Models
Sensing |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
|||
Through- |
Top-view |
E32-T15XR 2M |
280 |
190 |
130 |
55 |
Side-view |
E32-T15YR 2M |
100 |
75 |
80 |
21 |
|
Flat-view |
E32-T15ZR 2M |
|||||
Reflective |
Top-view |
E32-D15XR 2M |
120 |
90 |
60 |
21 |
Side-view |
E32-D15YR 2M |
28 |
20 |
13 |
5 |
|
Flat-view |
E32-D15ZR 2M |
Sleeve Models
Sensing |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
|||
Through- |
Top-view |
E32-TC200BR 2M |
280 |
190 |
130 |
55 |
Reflective |
Top-view |
E32-DC200BR 2M |
120 |
90 |
60 |
21 |
High-power Beam Models
Type |
Sensing |
Aperture |
Models |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
||||
Through-beam |
Side-view |
30° |
E32-T14 2M |
1800 |
1200 |
820 |
360 |