Smart Fiber Sensor
E3X-HD
Surprisingly Stable Detection with Your Finger tip. Exceptionally easy operation and stabilizing technology reduce maintenance cost.
Ratings and Specifications
Type |
Standard |
Model for |
|||
NPN output |
E3X-HD11 |
E3X-HD6 |
E3X-HD14 |
E3X-HD0 |
|
PNP output |
E3X-HD41 |
E3X-HD8 |
E3X-HD44 |
||
Connecting method |
Pre-wired |
Wire-saving |
M8 |
Communications |
|
Light source (wavelength) |
Red, 4-element LED (625 nm) |
||||
Power supply voltage |
12 to 24 VDC ±10%, ripple (P-P) 10% max. |
Supplied from the connector |
|||
Power |
Normal mode |
720 mW max. |
|||
Eco ON |
530 mW max. |
||||
Eco LO |
640 mW max. (Current consumption: 26 mA max. at |
- |
|||
Control output |
Load power supply voltage: 26.4 VDC max., open- |
- |
|||
Protection circuits |
Power supply reverse polarity protection, output |
Power supply reverse polarity |
|||
Response |
Super-high-speed |
NPN outputs: Operate or reset: 50 μs |
- |
||
High-speed Mode |
Operate or reset: 250 μs (default setting) |
||||
Standard Mode |
Operate or reset: 1 ms |
||||
Giga-power Mode |
Operate or reset: 16 ms |
||||
Maximum connectable Units |
16 units |
with E3X-CRT: 16 units |
|||
Mutual interference |
Possible for up to 10 units (optical communications sync) *3 |
||||
Auto power control (APC) |
Always ON |
||||
Other functions |
Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot), |
||||
Ambient illumination |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. |
||||
Ambient temperature range |
OOperating: |
Operating: |
|||
Ambient humidity range |
Operating and storage: 35% to 85% (with no condensation) |
||||
Insulation resistance |
20 MΩ min. (at 500 VDC) |
||||
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 minute |
||||
Vibration resistance |
10 to 55 Hz with a 1.5-mm double amplitude for |
10 to 150 Hz with a 0.7-mm |
|||
Shock resistance |
500 m/s2 for 3 times each in X, Y, and Z |
150 m/s2 for 3 times each in |
|||
Degree of protection |
IEC 60529 IP50 |
- |
|||
Weight |
Approx. 105 g/ |
Approx. 60 g/ |
Approx. 70 g/ |
Approx. 65 g/Approx. 25 g |
|
Materials |
Case |
Polycarbonate (PC) |
Heat-resistant ABS |
||
Cover |
Polycarbonate (PC) |
||||
Cable |
PVC |
- |
|||
Accessories |
Instruction Manual |
1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used.
2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor).
3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS).
When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units.
When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units.
E3X-DA[]-S Series in this catalog have been discontinued at the end of March 2017 and end of March 2019.
E3X-MDA Series will be accepted until the end of August 2021.
Sensing Distances
Threaded Models
Sensing |
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
||||
Through-beam |
Right-angle |
M4 |
E32-T11N 2M |
2,000 |
1,000 |
700 |
280 |
E32-LT11N 2M |
4,000 * |
3,500 |
2,300 |
920 |
|||
Straight |
E32-T11R 2M |
2,000 |
1,000 |
700 |
280 |
||
E32-LT11 2M |
4,000 * |
4,000 * |
2,700 |
1,080 |
|||
E32-LT11R 2M |
4,000 * |
3,500 |
2,300 |
920 |
|||
Reflective |
Right-angle |
M3 |
E32-C31N 2M |
110 |
50 |
46 |
14 |
E32-C21N 2M |
290 |
130 |
90 |
39 |
|||
M4 |
E32-D21N 2M |
840 |
350 |
240 |
100 |
||
M6 |
E32-C11N 2M |
780 |
350 |
320 |
100 |
||
E32-LD11N 2M |
840 |
350 |
240 |
100 |
|||
Straight |
M3 |
E32-D21R 2M |
140 |
60 |
40 |
16 |
|
E32-C31 2M |
330 |
150 |
100 |
44 |
|||
E32-C31M 1M |
|||||||
M4 |
E32-D211R 2M |
140 |
60 |
40 |
16 |
||
M6 |
E32-D11R 2M |
840 |
350 |
240 |
100 |
||
E32-CC200 2M |
1,400 |
600 |
400 |
180 |
|||
E32-LD11 2M |
860 |
360 |
250 |
110 |
|||
E32-LD11R 2M |
840 |
350 |
240 |
100 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Cylindrical Models
Sensing |
Size |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through- |
1 dia. |
Top-view |
E32-T223R 2M |
450 |
250 |
150 |
60 |
1.5 dia. |
E32-T22B 2M |
680 |
400 |
220 |
90 |
||
3 dia. |
E32-T12R 2M |
2,000 |
1,000 |
700 |
280 |
||
Side-view |
E32-T14LR 2M |
750 |
450 |
260 |
100 |
||
Reflective |
1.5 dia. |
Top-view |
E32-D22B 2M |
140 |
60 |
40 |
16 |
1.5 dia. + 0.5 dia. |
E32-D43M 1M |
28 |
12 |
8 |
4 |
||
3 dia. |
E32-D22R 2M |
140 |
60 |
40 |
16 |
||
E32-D221B 2M |
300 |
140 |
90 |
40 |
|||
E32-D32L 2M |
700 |
300 |
200 |
90 |
|||
3 dia. + 0.8 dia. |
E32-D33 2M |
70 |
30 |
20 |
8 |
Flat Models
Sensing |
Sensing direction |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
Top-view |
E32-T15XR 2M |
2,000 |
1,000 |
700 |
280 |
Side-view |
E32-T15YR 2M |
750 |
450 |
260 |
100 |
|
Flat-view |
E32-T15ZR 2M |
|||||
Reflective |
Top-view |
E32-D15XR 2M |
840 |
350 |
240 |
100 |
Side-view |
E32-D15YR 2M |
200 |
100 |
52 |
24 |
|
Flat-view |
E32-D15ZR 2M |
Sleeve Models
Sensing |
Sensing direction |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
Side-view |
E32-T24R 2M |
170 |
100 |
50 |
20 |
E32-T24E 2M |
450 |
250 |
150 |
60 |
||
Top-view |
E32-T33 1M |
150 |
90 |
50 |
20 |
|
E32-T21-S1 2M |
510 |
300 |
170 |
68 |
||
E32-TC200BR 2M |
2,000 |
1,000 |
700 |
280 |
||
Reflective |
Side-view |
E32-D24R 2M |
70 |
30 |
20 |
8 |
E32-D24-S2 2M |
120 |
53 |
45 |
14 |
||
Top-view |
E32-D43M 1M |
28 |
12 |
8 |
4 |
|
E32-D331 2M |
14 |
6 |
4 |
2 |
||
E32-D33 2M |
70 |
30 |
20 |
8 |
||
E32-D32-S1 0.5M |
63 |
24 |
18 |
7 |
||
E32-D31-S1 0.5M |
||||||
E32-DC200F4R 2M |
140 |
60 |
40 |
16 |
||
E32-D22-S1 2M |
250 |
110 |
72 |
30 |
||
E32-D21-S3 2M |
||||||
E32-DC200BR 2M |
840 |
350 |
240 |
100 |
||
E32-D25-S3 2M |
250 |
110 |
72 |
30 |
Small-spot, Reflective Models
Type |
Spot |
Center |
Models |
Sensing distance (mm) |
|||
Giga |
Standard |
High-speed |
Super-high- |
||||
Variable |
0.1 to 0.6 dia. |
6 to 15 |
E32-C42 1M+E39-F3A |
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. |
|||
0.3 to 1.6 dia. |
10 to 30 |
E32-C42 1M+E39-F17 |
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. |
||||
Parallel |
4 dia. |
0 to 20 |
E32-C31 2M+E39-F3C |
Spot diameter of 4 mm max. at 0 to 20 mm. |
|||
E32-C31N 2M+E39-F3C |
|||||||
Integrated |
0.1 dia. |
5 |
E32-C42S 1M |
Spot diameter of 0.1 mm at 5 mm. |
|||
6 dia. |
50 |
E32-L15 2M |
Spot diameter of 6 mm at 50 mm. |
||||
Small- |
0.1 dia. |
7 |
E32-C41 1M+E39-F3A-5 |
Spot diameter of 0.1 mm at 7 mm. |
|||
0.5 dia. |
E32-C31 2M+E39-F3A-5 |
Spot diameter of 0.5 mm at 7 mm. |
|||||
E32-C31N 2M+E39-F3A-5 |
|||||||
0.2 dia. |
17 |
E32-C41 1M+E39-F3B |
Spot diameter of 0.2 mm at 17 mm. |
||||
0.5 dia. |
E32-C31 2M+E39-F3B |
Spot diameter of 0.5 mm at 17 mm. |
|||||
E32-C31N 2M+E39-F3B |
|||||||
3 dia. |
50 |
E32-CC200 2M+E39-F18 |
Spot diameter of 3 mm at 50 mm. |
||||
E32-C11N 2M+E39-F18 |
High-power Beam Models
Type |
Sensing |
Aperture |
Models |
Sensing distance (mm) |
|||
Giga |
Standard |
High- |
Super- |
||||
Through-beam |
Right-angle |
15° |
E32-LT11N 2M |
4,000 *2 |
3,500 |
2,300 |
920 |
Top-view |
10° |
E32-T17L 10M |
20,000 *1 |
20,000 *1 |
20,000 *1 |
8,000 |
|
15° |
E32-LT11 2M |
4,000 *2 |
4,000 *2 |
2,700 |
1,080 |
||
E32-LT11R 2M |
4,000 *2 |
3,500 |
2,300 |
920 |
|||
Side-view |
30° |
E32-T14 2M |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
|
Through-beam |
Right-angle |
12° |
E32-T11N 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
2,000 |
6° |
E32-T11N 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,600 |
||
Top-view |
12° |
E32-T11R 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
2,000 |
|
6° |
E32-T11R 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,600 |
||
Side-view |
60° |
E32-T11R 2M+E39-F2 |
1,450 |
800 |
500 |
200 |
|
Top-view |
12° |
E32-T11 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,860 |
|
6° |
E32-T11 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Side-view |
60° |
E32-T11 2M+E39-F2 |
2,300 |
1,320 |
860 |
320 |
|
Top-view |
12° |
E32-T51R 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
3,900 |
1,500 |
|
6° |
E32-T51R 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Side-view |
60° |
E32-T51R 2M+E39-F2 |
1,400 |
720 |
500 |
200 |
|
Top-view |
12° |
E32-T81R-S 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
2,700 |
1,000 |
|
6° |
E32-T81R-S 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
||
Side-view |
60° |
E32-T81R-S 2M+E39-F2 |
1,000 |
550 |
360 |
140 |
|
Top-view |
12° |
E32-T61-S 2M+E39-F1 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
1,800 |
|
6° |
E32-T61-S 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
3,100 |
||
Side-view |
60° |
E32-T61-S 2M+E39-F2 |
1,680 |
900 |
600 |
240 |
|
Top-view |
12° |
E32-T51 2M+E39-F1-33 |
4,000 *2 |
4,000 *2 |
2,300 |
1,400 |
|
6° |
E32-T51 2M+E39-F16 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
4,000 *2 |
||
Reflective |
Top-view |
4° |
E32-D16 2M |
40 to |
40 to |
40 to 900 |
40 to 480 |
1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing |
Sensing |
Aperture |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through-beam |
Side-view |
1.5° |
E32-A03 2M |
3,220 |
1,780 |
1,200 |
500 |
E32-A03-1 2M |
|||||||
3.4° |
E32-A04 2M |
1,280 |
680 |
450 |
200 |
||
4° |
E32-T24SR 2M |
4,000 * |
2,200 |
1,460 |
580 |
||
E32-T24S 2M |
4,000 * |
2,600 |
1,740 |
700 |
|||
E32-T22S 2M |
4,000 * |
3,800 |
2,500 |
1,000 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Models for Detection without Background Interference
Sensing |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high-speed |
|||
Limited- |
Flat-view |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||
E32-L24S 2M |
0 to 4 |
|||||
Side-view |
E32-L25L 2M |
5.4 to 9 (center 7.2) |
Transparent Object Detection (Retro-reflective Models)
Sensing |
Feature |
Size |
Models |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Retro- |
Film detection |
M3 |
E32-C31 2M |
250 |
200 |
--- |
|
Square |
--- |
E32-R16 5M |
150 to 1,500 |
||||
Threaded |
M6 |
E32-R21 2M |
10 to 250 |
||||
Hex-shaped |
E32-LR11NP 2M |
1,350 |
1,200 |
1,000 |
550 |
Transparent Object Detection (Limited-reflective Models)
Sensing |
Feature |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga |
Standard |
High-speed |
Super-high- |
||||
Limited- |
Small size |
Flat-view |
E32-L24S 2M |
0 to 4 |
|||
Standard |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||||
Glass substrate |
E32-A08 2M |
10 to 20 |
--- |
||||
Standard/long-distance |
E32-A12 2M |
12 to 30 |
--- |
||||
Side-view form |
Side-view |
E32-L25L 2M |
5.4 to 9 (center 7.2) |
||||
Glass substrate |
Top-view |
E32-A09 2M |
15 to 38 |
--- |
Chemical-resistant, Oil-resistant Models
Sensing |
Type |
Sensing |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through- |
Oil-resistant |
Right-angle |
E32-T11NF 2M |
4,000 *1 |
4,000 *1 |
4,000 *1 |
2,200 |
Chemical/ |
Top-view |
E32-T12F 2M |
4,000 *1 |
4,000 *1 |
4,000 *1 |
1,600 |
|
E32-T11F 2M |
4,000 *1 |
4,000 *1 |
2,600 |
1,000 |
|||
Side-view |
E32-T14F 2M |
1,400 |
800 |
500 |
200 |
||
Chemical/ |
Top-view |
E32-T51F 2M |
4,000 *1 |
2,800 |
1,800 |
700 |
|
Reflective |
Semiconductors: |
Top-view |
E32-L11FP 5M |
8 to 20 mm from tip of lens (Recommended sensing |
|||
Semiconductors: |
E32-L11FS 5M |
8 to 20 mm from tip of lens (Recommended sensing |
|||||
Chemical/ |
E32-D12F 2M |
--- *2 |
190 |
130 |
60 |
||
Chemical- |
E32-D11U 2M |
840 |
350 |
240 |
100 |
1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high-speed |
|||
Through-beam |
1.5 dia. |
E32-T22B 2M |
680 |
400 |
220 |
90 |
M3 |
E32-T21 2M |
|||||
M4 |
E32-T11 2M |
2,500 |
1,350 |
900 |
360 |
|
Square |
E32-T25XB 2M |
500 |
300 |
170 |
70 |
|
Reflective |
1.5 dia. |
E32-D22B 2M |
140 |
60 |
40 |
16 |
M3 |
E32-D21 2M |
|||||
3 dia. |
E32-D221B 2M |
300 |
140 |
90 |
40 |
|
M4 |
E32-D21B 2M |
|||||
M6 |
E32-D11 2M |
840 |
350 |
240 |
100 |
|
Square |
E32-D25XB 2M |
240 |
100 |
60 |
30 |
Heat-resistant Models
Sensing |
Size |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard mode |
High-speed |
Super-high- |
|||
Through-beam |
100°C |
E32-T51R 2M |
1,600 |
800 |
560 |
225 |
150°C |
E32-T51 2M |
2,800 |
1,500 |
1,000 |
400 |
|
200°C |
E32-T81R-S 2M |
1,000 |
550 |
360 |
140 |
|
350°C |
E32-T61-S 2M |
1,680 |
900 |
600 |
240 |
|
Reflective |
100°C |
E32-D51R 2M |
670 |
280 |
190 |
80 |
150°C |
E32-D51 2M |
1,120 |
450 |
320 |
144 |
|
200°C |
E32-D81R-S 2M |
420 |
180 |
120 |
54 |
|
300°C |
E32-A08H2 2M |
10 to 20 |
--- |
|||
E32-A09H2 2M |
20 to 30 (center 25) |
--- |
||||
350°C |
E32-D611-S 2M |
420 |
180 |
120 |
54 |
|
E32-D61-S 2M |
||||||
400°C |
E32-D73-S 2M |
280 |
120 |
80 |
36 |
Area Detection Models
Sensing |
Type |
Sensing width |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Through-beam |
Area |
11 mm |
E32-T16PR 2M |
3,100 |
1,700 |
1,120 |
440 |
E32-T16JR 2M |
2,750 |
1,500 |
960 |
380 |
|||
30 mm |
E32-T16WR 2M |
4,000 |
2,600 |
1,700 |
680 |
||
Reflective |
Array |
11 mm |
E32-D36P1 2M |
700 |
300 |
200 |
90 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing |
Tube |
Feature |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Tube- |
3.2, 6.4, or |
Stable |
E32-A01 5M |
Applicable tube: Transparent tube with a diameter of 3.2, |
|||
8 to 10 dia |
Mounting at |
E32-L25T 2M |
Applicable tube: Transparent tube with a diameter of 8 |
||||
No |
Large tubes |
E32-D36T 5M |
Applicable tube: Transparent tube |
||||
Liquid contact |
--- |
--- |
E32-D82F1 4M |
Liquid-contact type |
Vacuum-resistant Models
Sensing |
Heat-resistant |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
|||
Through-beam |
120 °C |
E32-T51V 1M |
720 |
400 |
260 |
100 |
E32-T51V 1M+E39-F1V |
2,000 * |
2,000 * |
1,360 |
520 |
||
200 °C |
E32-T84SV 1M |
1,760 |
950 |
640 |
260 |
* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing |
Application |
Operating |
Model |
Sensing distance (mm) |
|||
Giga mode |
Standard |
High-speed |
Super-high- |
||||
Limited- |
Glass presence |
70°C |
E32-L16-N 2M |
0 to 15 |
0 to 12 |
||
E32-A08 2M |
10 to 20 |
--- |
|||||
Glass substrate |
300°C |
E32-A08H2 3M |
|||||
70°C |
E32-A12 2M |
12 to 30 |
--- |
||||
Glass substrate |
E32-A09 2M |
15 to 38 |
--- |
||||
300°C |
E32-A09H2 2M |
20 to 30 (center 25) |
--- |
||||
Wet processes: |
60°C |
E32-L11FP 5M |
8 to 20 mm from tip of lens |
||||
Wet process: |
85°C |
E32-L11FS 5M |
8 to 20 mm from tip of lens |
||||
Through- |
Wafer mapping |
70°C |
E32-A03 2M |
3,220 |
1,780 |
1,200 |
500 |
E32-A03-1 2M |
|||||||
E32-A04 2M |
1,280 |
680 |
450 |
200 |
|||
E32-T24SR 2M |
4,000 * |
2,200 |
1,460 |
580 |
|||
E32-T24S 2M |
4,000 * |
2,600 |
1,740 |
700 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.