Model

NPN output

ZX1-LD50A61
 ZX1-LD50A66

ZX1-LD100A61
 ZX1-LD100A66

ZX1-LD300A61
 ZX1-LD300A66

ZX1-LD600A61
 ZX1-LD600A66

PNP output

ZX1-LD50A81
 ZX1-LD50A86

ZX1-LD100A81
 ZX1-LD100A86

ZX1-LD300A81
 ZX1-LD300A86

ZX1-LD600A81
 ZX1-LD600A86

Measurement range

50 ± 10 mm

100 ± 35 mm

300 ± 150 mm

600 ± 400 mm

Light source (wave length)

Visible-light semiconductor laser
 (wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class 2 *1)

Spot diameter (typical)
 (Defined at the measurement
 center distance) *2

0.17 mm dia.

0.33 mm dia.

0.52 mm dia.

0.56 mm dia.

Power consumption

2,500 mW max. (105 mA max. at 24 VDC, 210 mA max. at 12 VDC)

Current consumption

250 mA max. (at power supply voltage 10 VDC)

Control output

Load power supply voltage: 30 VDC max., Load current: 100 mA max.
 (Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of
 10 to 100 mA))

Analog output

Current output: 4 to 20 mA, maximum load resistance: 300 Ω
 (The output is 20 mA for the nearest point in the measurement range in respect
 to the Sensor and 4 mA for the farthest point.)

Functions

Smart tuning, keep function, scaling setting, background removal, OFF-delay timer,
 ON-delay timer, one-shot timer, ON/OFF-delay timer, zero reset, area output,
 eco function, hysteresis width setting, and setting initialization

Indicators

Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator
 (orange), menu indicator (orange), laser ON indicator (green), and smart tuning
 indicator (blue)

Response
 time

Judgment output

Super-high-speed (SHS) Mode: 1 ms
 High-speed (HS) Mode: 10 ms
 Standard (Stnd) Mode: 100 ms

Laser OFF input

200 ms max.

Zero reset input

200 ms max.

Temperature characteristic *3

0.03% F.S./°C

0.04% F.S./°C

Linearity *4

±0.15% F.S.

±0.25% F.S.

±0.25% F.S.
 (200 to 600 mm)
 ±0.5% F.S.
 (entire range)

Resolution *5

2 μm

7 μm

30 μm

80 μm

Ambient illumination

Illumination on received light surface:
 7,500 lx or less (incandescent light)

Illumination on received light surface:
 5,000 lx or less (incandescent light)

Ambient temperature

Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Dielectric strength

1,000 VAC, 50/60 Hz, 1 minute

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 3 times each in X, Y, and Z directions

Degree of protection *6

IEC 60529, IP67

Connection method *7

Pre-wired model (Standard cable length: 2 m, 5 m)
 Pre-wired connector model (Standard cable length: 0.5 m)

Weight
 (packed
 state/
 sensor
 only)

Pre-wired models (2 m)

Approx. 240 g/Approx. 180 g

Approx. 270 g/Approx. 210 g

Pre-wired models (5 m)

Approx. 450 g/Approx. 330 g

Approx. 480 g/Approx. 360 g

Pre-wired connector
 models (0.5 m)

Approx. 170 g/Approx. 110 g

Approx. 200 g/Approx. 140 g

Materials

Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable:
 PVC, Mounting hole part: SUS303

Accessories

Instruction sheet and Laser warning label (English)

Note: 1. False detection outside the measurement range can occur in the case of an object with high reflectance.
           2. Refer to the below for the ratings and specifications of Sensors with Class 1 lasers.
 1. Classified as Class 2 by IEC60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50.
  CDRH registration has been completed. (Center for Devices and Radiological Health) (Accession Number: 1210041)  
2. Spot diameter: Defined as 1/e2 (13.5%) of the central intensity at the measurement center distance.
        False detections can occur in the case there is light leakage outside the defined region and the surroundings of the
        target object have a high reflectance in comparison to the target object.
        Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
 *3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is
        secured by an aluminum jig. (Measured at the measurement center distance)
 *4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring
        Omron’s standard target object (white ceramic) at a temperature of 25 °C.
        Linearity and measured value may vary depending on target object.
 *5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart
        Tuning.
        The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
        Resolution performance may not be satisfied in a strong electromagnetic field.
 *6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected.
 *7. Use a Pre-wired Connector Model together with an Extension Cable (10 m or 20 m). 

Ratings and Specifications of Sensors with Class 1 lasers (ZX1-LD[]L)

The ratings and specifications that are different from those of the Sensors with Class 2 lasers are given below. 

Model

ZX1-LD50A61L/ZX1-LD50A81L
 ZX1-LD100A61L/ZX1-LD100A81L

ZX1-LD300A61L/ZX1-LD300A81L
 ZX1-LD600A61L/ZX1-LD600A81L

FDA Class

Class1 0.24mW max.

IEC/EN Class

Class1 0.24mW max.

Functions

No scaling setting

Ambient illumination

Illumination on received light surface 5,000 lx
 or less (incandescent light)

Illumination on received light surface 2,500 lx
 or less (incandescent light)

Connection method

Pre-wired model (2 m)

Accessories

Instruction sheet and Explanatory label (English), FDA certification label