Product Category

Built-in Power Supply Photoelectric Sensor

E3JK (NEW)

Long-distance Photoelectric Sensor That Supports AC/DC Power Supplies

Sensing method

Through-beam

Model

E3JK-TR11-[]

E3JK-TR12-[]

E3JK-TR13-[]

E3JK-TR14-[]

Sensing distance

40 m

5 m

40 m

5 m

Standard sensing object

Opaque: 17-mm dia. min.

Differential travel

-

Directional angle

Both Emitter and Receiver 3° min.

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Power supply voltage

24 to 240 VDC ±10%,
 ripple (p-p): 10% max.
 24 to 240 VAC ±10%, 50/60 Hz

Power
 consumption

DC

3 W max. (Emitter 1.5 W max. Receiver 1.5 W max.)

AC

3 W max. (Emitter 1.5 W max. Receiver 1.5 W max.)

Control output

Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1),
 5 VDC, 10 mA min.,
 Light-ON/Dark-ON selectable

Protection circuits

-

Life
 expectancy
 (relay output)

Mechanical

50,000,000 times min. (switching frequency: 18,000 times/h)

Electrical

100,000 times min. (switching frequency: 1,800 times/h)

Response time

20 ms max.

Sensitivity adjustment

One-turn adjuster Receiver (E3JK-TR1[]-D) only

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

100 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 350 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual and Mounting Bracket (E3JK-TR1[]-C only)

Sensing method

Retro-reflective
 (without MSR function)

Retro-reflective
 (with MSR function)

Model

E3JK-RR11-[]

E3JK-RR13-[]

E3JK-RR12-[]

Sensing distance

7 m [100 mm]* (When using E39-R1),
 11 m [100 mm]* (When using E39-R2)

6 m [100 mm]* (When using E39-R1),
 10 m [100 mm]* (When using E39-R2)

Standard sensing object

Opaque: 75-mm dia. min. (When using E39-R1), Opaque: 100-mm dia. min. (When
 using E39-R2)

Differential travel

-

Directional angle

1.5° min.

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Red LED (624 nm)

Power supply voltage

24 to 240 VDC ±10%,
 ripple (p-p): 10% max.
 24 to 240 VAC ±10%, 50/60 Hz

Power
 consumption

DC

2 W max.

AC

2 W max.

Control output

Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1),
 5 VDC, 10 mA min.,
 Light-ON/Dark-ON selectable

Protection circuits

Mutual interference prevention function

Life
 expectancy
 (relay output)

Mechanical

50,000,000 times min. (switching frequency: 18,000 times/h)

Electrical

100,000 times min. (switching frequency: 1,800 times/h)

Response time

20 ms max.

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

100 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 180 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual, Mounting Bracket (E3JK-RR1[]-C only), and Reflector (E3JK-
 RR1[]-C only)








*Values in parentheses indicate the minimum required distances between the Sensors and Reflectors. 

Sensing method

Diffuse-reflective

Model

E3JK-DR11-[]

E3JK-DR12-[]

E3JK-DR13-[]

E3JK-DR14-[]

Sensing distance

White paper
 (300 × 300 mm): 2.5 m

White paper
 (100 × 100 mm): 300 mm

White paper
 (300 × 300 mm): 2.5 m

White paper
 (100 × 100 mm): 300 mm

Standard sensing object

-

Differential travel

20% max. of sensing distance

Directional angle

-

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Power supply voltage

24 to 240 VDC ±10%,
 ripple (p-p): 10% max.
 24 to 240 VAC ±10%, 50/60 Hz

Power
 consumption

DC

2 W max.

AC

2 W max.

Control output

Relay output SPDT, 250 VAC, 3 A max. (cosϕ= 1),
 5 VDC, 10 mA min.,
 Light-ON/Dark-ON selectable

Protection circuits

Mutual interference prevention function

Life
 expectancy
 (relay output)

Mechanical

50,000,000 times min. (switching frequency: 18,000 times/h)

Electrical

100,000 times min. (switching frequency: 1,800 times/h)

Response time

20 ms max.

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

100 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 180 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual and Mounting Bracket (E3JK-DR1[]-C only)

Sensing method

Through-beam

Model

NPN output

E3JK-TN11

E3JK-TN12

E3JK-TN13

E3JK-TN14

PNP output

E3JK-TP11

E3JK-TP12

E3JK-TP13

E3JK-TP14

Sensing distance

40 m

5 m

40 m

5 m

Standard sensing object

Opaque: 17-mm dia. min.

Differential travel

-

Directional angle

Both Emitter and Receiver 3° min.

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Power supply voltage

10 to 30 VDC, including ripple (p-p): 10%

Power
 consumption

DC

40 mA max. (Emitter 25 mA max. Receiver 15 mA max.)

AC

-

Control output

Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., open-collector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection

Life
 expectancy
 (relay output)

Mechanical

-

Electrical

-

Response time

1 ms max.

Sensitivity adjustment

One-turn adjuster Receiver (E3JK-T[][][]-D) only

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 300 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual

 

Sensing method

Retro-reflective (without MSR function)

Retro-reflective
 (with MSR function)

Model

NPN output

E3JK-RN11

E3JK-RN13

E3JK-RN12

PNP output

E3JK-RP11

E3JK-RP13

E3JK-RP12

Sensing distance

7 m [100 mm]* (When using E39-R1),
 11 m [100 mm]* (When using E39-R2)

6 m [100 mm]* (When using E39-R1),
 10 m [100 mm]* (When using E39-R2)

Standard sensing object

Opaque: 75-mm dia. min.

Differential travel

-

Directional angle

1.5° min.

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Red LED (624 nm)

Power supply voltage

10 to 30 VDC, including ripple (p-p): 10%

Power
 consumption

DC

30 mA max.

AC

-

Control output

Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., opencollector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention function, and Output reverse polarity protection

Life
 expectancy
 (relay output)

Mechanical

-

Electrical

-

Response time

1 ms max.

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 160 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual

*Values in parentheses indicate the minimum required distances between the Sensors and Reflectors. 

Sensing method

Diffuse-reflective

Model

NPN output

E3JK-DN11

E3JK-DN12

E3JK-DN13

E3JK-DN14

PNP output

E3JK-DP11

E3JK-DP12

E3JK-DP13

E3JK-DP14

Sensing distance

White paper
 (300 × 300 mm): 2.5 m

White paper
 (100 × 100 mm): 300 mm

White paper
 (300 × 300 mm): 2.5 m

White paper
 (100 × 100 mm): 300 mm

Standard sensing object

-

Differential travel

20% max. of sensing distance

Directional angle

-

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Power supply voltage

10 to 30 VDC, including ripple (p-p): 10%

Power
 consumption

DC

30 mA max.

AC

-

Control output

Load power supply voltage: 30 V max., Load current: 100 mA max., Residual voltage: 3 V max., opencollector output (NPN/PNP output depending on model), Light-ON/Dark-ON selectable

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention function, and Output reverse polarity protection

Life
 expectancy
 (relay output)

Mechanical

-

Electrical

-

Response time

1 ms max.

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max., Sunlight: 11,000 lx max.

Ambient temperature range

Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,500 VAC, 50/60 Hz for 1 min

Vibration
 resistance

Destruction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Malfunction

10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock
 resistance

Destruction

500 m/s2 for 3 times each in X, Y, and Z directions

Malfunction

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP64

Connection method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 160 g

Material

Case

ABS (Acrylonitrile Butadiene Styrene)

Lens/Display
 window

Methacrylic resin

Adjuster

POM

Cable

PVC

Bending radius of cable

R18

Accessories

Instruction manual