Standard models/ Advanced models/ Infrared models

Type

Standard models

NPN output

E3NX-FA11

E3NX-FA6

E3NX-FA11-5 *1

PNP output

E3NX-FA41

E3NX-FA8

---

Connecting method

Pre-wired

Wire-saving Connector

Pre-wired

Inputs/
 outputs

Outputs

1 output

External inputs

---

Light source (wavelength)

Red, 4-element LED (625 nm)

Power supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Power consumption *2

At Power supply voltage of 24 VDC
 Standard Models:
  Normal mode: 840 mW max. (Current consumption at 35 mA max.)
  Eco function ON: 650 mW max. (Current consumption at 27 mA max.)
  Eco function LO: 750 mW max. (Current consumption at 31 mA max.)
 
 Advanced Models or Model for Sensor Communications Unit:
  Normal mode: 920 mW max. (Current consumption at 38 mA max.)
  Eco function ON: 680 mW max. (Current consumption at 28 mA max.)
  Eco function LO: 800 mW max. (Current consumption at 33 mA max.)
 
 Infrared models:
  Normal mode: 1080 mW max. (Current consumption at 45 mA max.)
  Eco function ON: 920 mW max. (Current consumption at 38 mA max.)
  Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)

Control output

Load power supply voltage: 30 VDC max., open-collector output
 (depends on the NPN/PNP output format)
 Load current: Groups of 1 to 3 Amplifier Units: 100 mA max.,
 Groups of 4 to 30 Amplifier Units: 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

External inputs

---

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
 DPC indicator (green), and OUT selection indicator
 (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Response
 time

Super-high-speed mode (SHS)

Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs

High-speed mode (HS)

Operate or reset: 250 μs

Standard mode (Stnd)

Operate or reset: 1 ms

Giga-power mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment

Maximum connectable Units

30

No. of
 Units for
 mutual
 interference
 prevention
 *4

Super-high-speed mode (SHS)

0
 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.

High-speed mode (HS)

10

Standard mode (Stnd)

10

Giga-power mode (GIGA)

10

Functions

Automatic power control
 (APC)

Always enabled.

Dynamic power control
 (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings *5

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode *6

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Power tuning

Select from ON, OFF or Execution on power-up.

Output 1

Select from normal detection mode, area detection mode or differential detection mode.

Output 2

---

External input

---

Hysteresis width

Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.

Ambient illumination (Receiver side)

Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.

Ambient temperature range *7

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C,
 Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C,
 Groups of 17 to 30 Amplifier Units: -25 to 40°C
 Storage: -30 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation)
 within the surrounding air temperature range shown above

Altitude

2,000 m max.

Installation environment

Pollution degree 3

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Weight (packed state/Sensor only)

Approx. 115 g/
 approx. 75 g

Approx. 60 g/
 approx. 20 g

Approx. 115 g/
 approx. 75 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

PVC

Accessories

Instruction Manual

Type

Advanced models

NPN output

E3NX-FA21

E3NX-FA7

E3NX-FA7TW

E3NX-FA24

---

PNP output

E3NX-FA51

E3NX-FA9

E3NX-FA9TW

E3NX-FA54

E3NX-FA54TW

Connecting method

Pre-wired

Wire-saving Connector

M8 Connector

Inputs/
 outputs

Outputs

2 outputs

1 output

2 outputs

1 output

2 outputs

External inputs

1 input

1 input

---

1 input

---

Light source (wavelength)

Red, 4-element LED (625 nm)

Power supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Power consumption *2

At Power supply voltage of 24 VDC
 Standard Models:
  Normal mode: 840 mW max. (Current consumption at 35 mA max.)
  Eco function ON: 650 mW max. (Current consumption at 27 mA max.)
  Eco function LO: 750 mW max. (Current consumption at 31 mA max.)
 
 Advanced Models or Model for Sensor Communications Unit:
  Normal mode: 920 mW max. (Current consumption at 38 mA max.)
  Eco function ON: 680 mW max. (Current consumption at 28 mA max.)
  Eco function LO: 800 mW max. (Current consumption at 33 mA max.)
 
 Infrared models:
  Normal mode: 1080 mW max. (Current consumption at 45 mA max.)
  Eco function ON: 920 mW max. (Current consumption at 38 mA max.)
  Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)

Control output

Load power supply voltage: 30 VDC max., open-collector output
 (depends on the NPN/PNP output format)
 Load current: Groups of 1 to 3 Amplifier Units: 100 mA max.,
 Groups of 4 to 30 Amplifier Units: 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

External inputs

Refer to *3.

---

Refer to *3.

---

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
 DPC indicator (green), and OUT selection indicator
 (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection, output short-circuit protection,
 and output reverse polarity protection

Response
 time

Super-high-speed mode (SHS)

Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs

High-speed mode (HS)

Operate or reset: 250 μs

Standard mode (Stnd)

Operate or reset: 1 ms

Giga-power mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment

Maximum connectable Units

30

No. of
 Units for
 mutual
 interference
 prevention
 *4

Super-high-speed mode (SHS)

0
 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.

High-speed mode (HS)

10

Standard mode (Stnd)

10

Giga-power mode (GIGA)

10

Functions

Automatic power control
 (APC)

Always enabled.

Dynamic power control
 (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings *5

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode *6

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Power tuning

Select from ON, OFF or Execution on power-up.

Output 1

Select from normal detection mode, area detection mode or differential detection mode.

Output 2

Select from
 normal
 detection
 mode,
 alarm
 output
 mode, error
 output
 mode or
 differential
 detection
 mode.

---

Select from
 normal
 detection
 mode,
 alarm
 output
 mode, error
 output
 mode or
 differential
 detection
 mode.

---

Select from
 normal
 detection
 mode,
 alarm
 output
 mode, error
 output
 mode or
 differential
 detection
 mode.

External input

Select from input OFF,
 tuning, power tuning,
 emission OFF, Sensor
 OFF, zero reset, or bank
 switching.

---

Select
 from input
 OFF,
 tuning,
 power
 tuning,
 emission
 OFF,
 Sensor
 OFF, zero
 reset, or
 bank
 switching.

---

Hysteresis width

Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.

Ambient illumination (Receiver side)

Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.

Ambient temperature range *7

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C,
 Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C,
 Groups of 17 to 30 Amplifier Units: -25 to 40°C
 Storage: -30 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation)
 within the surrounding air temperature range shown above

Altitude

2,000 m max.

Installation environment

Pollution degree 3

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Weight (packed state/Sensor only)

Approx. 115 g/
 approx. 75 g

Approx. 60g/approx. 20g

Approx. 65 g/
 approx. 25 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

PVC

Accessories

Instruction Manual









 

Type

Infrared models

NPN output

E3NX-FAH11

E3NX-FAH6

PNP output

E3NX-FAH41

E3NX-FAH8

Connecting method

Pre-wired

Wire-saving
 Connector

Inputs/
 outputs

Outputs

1 outputs

External inputs

---

Light source (wavelength)

Infrared LED (870nm)

Power supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Power consumption *2

At Power supply voltage of 24 VDC
 Standard Models:
  Normal mode: 840 mW max. (Current consumption at 35 mA max.)
  Eco function ON: 650 mW max. (Current consumption at 27 mA max.)
  Eco function LO: 750 mW max. (Current consumption at 31 mA max.)
 
 Advanced Models or Model for Sensor Communications Unit:
  Normal mode: 920 mW max. (Current consumption at 38 mA max.)
  Eco function ON: 680 mW max. (Current consumption at 28 mA max.)
  Eco function LO: 800 mW max. (Current consumption at 33 mA max.)
 
 Infrared models:
  Normal mode: 1080 mW max. (Current consumption at 45 mA max.)
  Eco function ON: 920 mW max. (Current consumption at 38 mA max.)
  Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)

Control output

Load power supply voltage: 30 VDC max., open-collector output
 (depends on the NPN/PNP output format)
 Load current: Groups of 1 to 3 Amplifier Units: 100 mA max.,
 Groups of 4 to 30 Amplifier Units: 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

External inputs

---

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
 DPC indicator (green), and OUT selection indicator
 (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection

Response
 time

Super-high-speed mode (SHS)

Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs

High-speed mode (HS)

Operate or reset: 250 μs

Standard mode (Stnd)

Operate or reset: 1 ms

Giga-power mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment

Maximum connectable Units

30

No. of
 Units for
 mutual
 interference
 prevention
 *4

Super-high-speed mode (SHS)

0
 Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.

High-speed mode (HS)

10

Standard mode (Stnd)

10

Giga-power mode (GIGA)

10

Functions

Automatic power control
 (APC)

Always enabled.

Dynamic power control
 (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings *5

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode *6

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Power tuning

Select from ON or OFF.

Output 1

Select from normal detection mode or area detection mode.

Output 2

---

External input

---

Hysteresis width

Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.

Ambient illumination (Receiver side)

Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.

Ambient temperature range *7

Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C,
 Groups of 3 to 10 Amplifier Units: -25 to 50°C,
 Groups of 11 to 16 Amplifier Units: -25 to 45°C,
 Groups of 17 to 30 Amplifier Units: -25 to 40°C
 Storage: -30 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation)
 within the surrounding air temperature range shown above

Altitude

2,000 m max.

Installation environment

Pollution degree 3

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 for 3 times each in X, Y, and Z directions

Weight (packed state/Sensor only)

Approx. 115 g/approx. 75 g

Approx. 60g/approx. 20g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

PVC

Accessories

Instruction Manual

1. This type can prevent mutual interference for two units in the SHS2 mode.
 2. At Power supply voltage of 10 to 30 VDC
        Standard Models:
          Normal mode : 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC)
          Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC)
          Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC)
        Advanced Models:
          Normal mode : 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC)
          Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC)
          Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC)
        Infrared models:
          Normal mode : 1,260 mW max. (Current consumption: 42 mA max. at 30 VDC, 80 mA max. at 10 VDC)
          Eco function ON : 1,050 mW max. (Current consumption: 35 mA max. at 30 VDC, 60 mA max. at 10 VDC)
          Eco function LO : 1,140 mW max. (Current consumption: 38 mA max. at 30 VDC, 70 mA max. at 10 VDC)
 3. The following details apply to the input.


Contact input (relay or switch)

Non-contact input (transistor)

Input time*3-1

NPN

ON: Shorted to 0 V (Sourcing current: 1 mA
 max.).
 OFF: Open or shorted to Vcc.

ON: 1.5 V max. (Sourcing current: 1 mA max.)
 OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1
 mA max.)

ON: 9 ms min.
 OFF: 20 ms min.

PNP

ON: Shorted to Vcc (Sinking current: 3 mA
 max.).
 OFF: Open or shorted to 0 V.

ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA
 max.)
 OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.

4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC. Check the mutual interference prevention unit count and response speed of each model.
 5. The bank is not reset by the user reset function or saved by the user save function.
 6. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
 7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.

Analog output models/ Model for Sensor Communications Unit

Type

Analog output
 models

Model for Sensor Communications Unit

NPN output

E3NX-FA11AN

E3NX-FA10

E3NX-FA0

E3NX-FAH0

PNP output

E3NX-FA41AN

E3NX-FA40

Connecting method

Pre-wired

Connector for
 Sensor
 Communications
 Unit Pre-wired

Connector for Sensor
 Communications Unit

Inputs/
 outputs

Outputs

2 outputs

1 outputs

--- *1

External
 inputs

---

---

Light source
 (wavelength)

Red, 4-element LED (625 nm)

Infrared LED (870nm)

Power supply voltage

10 to 30 VDC, including
 10% ripple (p-p)

Supplied from the connector through the communication units.

Power consumption *2

At Power supply
 voltage of 24 VDC
 Normal mode: 960 mW
 max.
 (Current consumption at
 40 mA max.)
 Eco function ON: 770
 mW max.
 (Current consumption at
 32 mA max.)
 Eco function LO: 870
 mW max.
 (Current consumption at
 36 mA max.)

At Power supply voltage of 24
 VDC
 Normal mode: 920 mW max.
 (Current consumption at 38 mA
 max.)
 Eco function ON: 680 mW max.
 (Current consumption at 26 mA
 max.)
 Eco function LO: 800 mW max.
 (Current consumption at 33 mA
 max.)

At Power supply voltage
 of 24 VDC
 Normal mode: 1,080
 mW max.
 (Current consumption at
 45 mA max.)
 Eco function ON: 920
 mW max.
 (Current consumption at
 38 mA max.)
 Eco function LO: 1,020
 mW max.
 (Current consumption at
 42 mA max.)

Control output

Load power supply voltage:
 30 VDC max., open-collector output
 (depends on the NPN/PNP output format)
 Load current: Groups of 1 to 3 Amplifier Units:
 100 mA max., Groups of 4 to 30 Amplifier Units:
 20 mA max.
 (Residual voltage:
 At load current of less than 10 mA: 1 V max.
 At load current of 10 to 100 mA: 2 V max.)
 OFF current: 0.1 mA max.

---

Analog output
 (reference value)

Voltage output: 1-5 VDC
 (10 kΩ or more
 connected load),
 temperature
 characteristics: 0.3%
 F.S. / °C

---

Indicators

7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed.
 OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green),
 and OUT selection indicator (orange, only on models with 2 outputs)

Protection circuits

Power supply reverse polarity protection,
 output short-circuit protection, and output
 reverse polarity protection

Power supply reverse polarity
 protection and output short-circuit
 protection

Control
 output
 Response
 time

Super-high-
 speed mode
 (SHS)

Operate or reset:
 80 μs

Operate or reset: 32 μs

High-speed
 mode (HS)

Operate or reset:
 250μs

Operate or reset: 250 μs

Standard
 mode (Stnd)

Operate or reset:
 1 ms

Operate or reset: 1 ms

Giga-power
 mode (GIGA)

Operate or reset:
 16 ms

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning,
 power tuning, percentage tuning (-99% to 99%)) or manual adjustment

Maximum connectable Units

30

16

With E3NW-ECT: 30 units
 (When connected to an OMRON NJ-
 series Controller.)
 With E3NW-CRT: 16 units
 (Note: E3NX-FAH0 can not be
 connected.)
 With E3NW-CCL: 16 units

No. of
 Units for
 mutual
 inter-
 ference
 preven-
 tion *3

Super-high-
 speed mode
 (SHS)

0 (The mutual interference prevention function is disabled if the detection mode is set to
 super-high-speed mode.)

High-speed
 mode (HS)

10

Standard
 mode (Stnd)

10

Giga-power
 mode (GIGA)

10

Func-
 tions

Automatic
 power
 control
 (APC)

Always enabled.

Dynamic
 power
 control
 (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer:
 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting
 settings *4

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display
 dimmed).

Bank
 switching

Select from banks 1 to 4.

Sensor OFF
 setting

---

Select from
 ON or OFF.

---

Power
 tuning

Select from ON or OFF.

Output 1

Select from normal detection mode, area detection mode or differential detection mode
 (E3NX-FA10/40 only).

Output 2

Select from Analog
 scaling or Analog offset

---

Select from normal detection mode,
 alarm output mode, error output mode
 or differential detection mode (E3NX-
 FA0 only).

Hysteresis
 width

Select from standard setting or user setting. For a user setting, the hysteresis width can
 be set from 0 to 9,999.

Ambient illumination
 (Receiver side)

Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.

Ambient temperature
 range *5

Operating:
 Groups of 1 or 2
 Amplifier Units: -25 to
 55°C,
 Groups of 3 to 10
 Amplifier Units: -25 to
 50°C,
 Groups of 11 to 16
 Amplifier Units: -25 to
 45°C,
 Groups of 17 to 30
 Amplifier Units: -25 to
 40°C
 Storage: -30 to 70°C
 (with no icing or
 condensation)

Operating:
 Groups of 1 or 2
 Amplifier Units: 0 to
 55°C,
 Groups of 3 to 10
 Amplifier Units: 0 to
 50°C,
 Groups of 11 to 16
 Amplifier Units: 0 to
 45°C
 Storage: -30 to 70°C
 (with no icing or
 condensation)

Operating:
 Groups of 1 or 2 Amplifier Units: 0 to
 55°C,
 Groups of 3 to 10 Amplifier Units: 0 to
 50°C,
 Groups of 11 to 16 Amplifier Units: 0 to
 45°C,
 Groups of 17 to 30 Amplifier Units: 0 to
 40°C
 Storage: -30 to 70°C (with no icing or
 condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation) within the surrounding air
 temperature range shown above

Altitude

2,000 m max.

Installation environment

Pollution degree 3

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min

Vibration resistance
 (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

500 m/s2 for 3 times
 each in X, Y, and Z
 directions

150 m/s2 for 3 times each in X, Y, and Z directions

Weight (packed state/
 Sensor only)

Approx. 115 g/
 approx. 75 g

Approx. 95 g/
 approx. 45 g

Approx. 65 g/
 approx. 25 g

Approx. 65 g/
 approx. 25 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

PVC

Accessories

Instruction Manual

1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
       PLC operation via Communications Unit enables reading detected values and changing settings.
 2. At Power supply voltage of 10 to 30 VDC
       Analog output models:
         Normal mode : 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
         Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
         Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
 3. The tuning will not change the number of units.
       The least unit count among the mutual interference prevention units of E3NX and E3NC.
       Check the mutual interference prevention unit count and response speed of each model.
 4. The bank is not reset by the user reset function or saved by the user save function.
 5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C. 

Sensing Distances

Standard models/ Advanced models/ Analog output models

Threaded Models

Sensing
 method

Sensing
 direction

Size

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

Right-angle

M4

E32-T11N 2M

3,000

1,500

1,050

280

E32-LT11N 2M

4,000*1

4,000*1

3,450

920

Straight

E32-T11R 2M

3,000

1,500

1,050

280

E32-LT11 2M

4,000*1

4,000*1

4,000*1

1,080

E32-LT11R 2M

4,000*1

4,000*1

3,450

920

Reflective

Right-angle

M3

E32-C31N 2M

160

75

69

14

E32-C21N 2M

440

190

130

39

M4

E32-D21N 2M

1,260

520

360

100

M6

E32-C11N 2M

1,170

520

480

100

E32-LD11N 2M

1,260

520

360

100

Straight

M3

E32-D21R 2M

210

90

60

16

E32-C31 2M

490

220

150

44

E32-C31M 1M

M4

E32-D211R 2M

210

90

60

16

M6

E32-D11R 2M

1,260

520

360

100

E32-CC200 2M

2,100

900

600

180

E32-LD11 2M

1,290

540

370

110

E32-LD11R 2M

1,260

520

360

100

Cylindrical Models

Sensing
 method

Size

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

1 dia.

Top-view

E32-T223R 2M

670

370

220

60

1.5 dia.

E32-T22B 2M

1,020

600

330

90

3 dia.

E32-T12R 2M

3,000

1,500

1,050

280

Side-view

E32-T14LR 2M

1,120

670

390

100

Reflective

1.5 dia.

Top-view

E32-D22B 2M

210

90

60

16

1.5 dia. + 0.5 dia.

E32-D43M 1M

42

18

12

4

3 dia.

E32-D22R 2M

210

90

60

16

E32-D221B 2M

450

210

130

40

E32-D32L 2M

1,050

450

300

90

3 dia. + 0.8 dia.

E32-D33 2M

100

45

30

8

Flat Models

Sensing
 method

Sensing direction

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

Top-view

E32-T15XR 2M

3,000

1,500

1,050

280

Side-view

E32-T15YR 2M

1,120

670

390

100

Flat-view

E32-T15ZR 2M

Reflective

Top-view

E32-D15XR 2M

1,260

520

360

100

Side-view

E32-D15YR 2M

300

150

78

24

Flat-view

E32-D15ZR 2M

Sleeve Models

Sensing
 method

Sensing direction

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

Side-view

E32-T24R 2M

250

150

75

20

E32-T24E 2M

670

370

220

60

Top-view

E32-T33 1M

220

130

75

20

E32-T21-S1 2M

760

450

250

68

E32-TC200BR 2M

3,000

1,500

1,050

280

Reflective

Side-view

E32-D24R 2M

100

45

30

8

E32-D24-S2 2M

180

79

67

14

Top-view

E32-D43M 1M

42

18

12

4

E32-D331 2M

21

9

6

2

E32-D33 2M

100

45

30

8

E32-D32-S1 0.5M

94

40

27

7

E32-D31-S1 0.5M

E32-DC200F4R 2M

210

90

60

16

E32-D22-S1 2M

370

160

100

30

E32-D21-S3 2M

E32-DC200BR 2M

1,260

520

360

100

E32-D25-S3 2M

370

160

100

30

Small-spot, Reflective Models

Type

Spot
 diameter

Center
 distance
 (mm)

Models

Sensing distance (mm)

Giga
 mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Variable
 spot

0.1 to 0.6 dia.

6 to 15

E32-C42 1M + E39-F3A

Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.

0.3 to 1.6 dia.

10 to 30

E32-C42 1M + E39-F17

Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.

Parallel
 light

4 dia.

0 to 20

E32-C31 2M + E39-F3C

Spot diameter of 4 mm max. at 0 to 20 mm.

E32-C31N 2M + E39-F3C

Integrated
 lens

0.1 dia.

5

E32-C42S 1M

Spot diameter of 0.1 mm at 5 mm.

6 dia.

50

E32-L15 2M

Spot diameter of 6 mm at 50 mm.

Small-
 spot

0.1 dia.

7

E32-C41 1M + E39-F3A-5

Spot diameter of 0.1 mm at 7 mm.

0.5 dia.

E32-C31 2M + E39-F3A-5

Spot diameter of 0.5 mm at 7 mm.

E32-C31N 2M + E39-F3A-5

0.2 dia.

17

E32-C41 1M + E39-F3B

Spot diameter of 0.2 mm at 17 mm.

0.5 dia.

E32-C31 2M + E39-F3B

Spot diameter of 0.5 mm at 17 mm.

E32-C31N 2M + E39-F3B

3 dia.

50

E32-CC200 2M + E39-F18

Spot diameter of 3 mm at 50 mm.

E32-C11N 2M + E39-F18

High-power Beam Models

Type

Sensing
 direction

Center
 distance
 (mm)

Models

Sensing distance (mm)

Giga
 mode

Standard
 mode

High-
 speed
 mode

Super-
 high-
 speed
 mode

Through-beam
 models with
 integrated
 lens

Right-angle

15°

E32-LT11N 2M

4,000*2

4,000*2

3,450

920

Top-view

10°

E32-T17L 10M

20,000 *1

20,000 *1

20,000 *1

8,000

15°

E32-LT11 2M

4,000 *2

4,000 *2

4,000 *2

1,080

E32-LT11R 2M

4,000 *2

4,000 *2

3,450

920

Side-view

30°

E32-T14 2M

4,000 *2

4,000 *2

4,000 *2

1,800

Through-beam
 models with
 lenses

Right-angle

12°

E32-T11N 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

2,000

E32-T11N 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

3,600

Top-view

12°

E32-T11R 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

2,000

E32-T11R 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

3,600

Side-view

60°

E32-T11R 2M + E39-F2

2,170

1,200

750

200

Top-view

12°

E32-T11 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

1,860

E32-T11 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

4,000 *2

Side-view

60°

E32-T11 2M + E39-F2

3,450

1,980

1,290

320

Top-view

12°

E32-T51R 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

1,500

E32-T51R 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

4,000 *2

Side-view

60°

E32-T51R 2M + E39-F2

2,100

1,080

750

200

Top-view

12°

E32-T81R-S 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

1,000

E32-T81R-S 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

1,800

Side-view

60°

E32-T81R-S 2M + E39-F2

1,500

820

540

140

Top-view

12°

E32-T61-S 2M + E39-F1

4,000 *2

4,000 *2

4,000 *2

1,800

E32-T61-S 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

3,100

Side-view

60°

E32-T61-S 2M + E39-F2

2,520

1,350

900

240

Top-view

12°

E32-T51 2M + E39-F1-33

4,000 *2

4,000 *2

3,450

1,400

E32-T51 2M + E39-F16

4,000 *2

4,000 *2

4,000 *2

4,000 *2

Reflective
 models with
 integrated lens

Top-view

E32-D16 2M

40 to
 4,200

40 to
 2,100

40 to
 1,350

40 to 720

1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
 2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 

Narrow View Models

Sensing
 method

Sensing
 direction

Aperture
 angle

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

Side-view

1.5°

E32-A03 2M

4,000 *1

2,670

1,800

500

E32-A03-1 2M

3.4°

E32-A04 2M

1,920

1,020

670

200

E32-T24SR 2M

4,000 *1

3,300

2,190

580

E32-T24S 2M

4,000 *1

3,900

2,610

700

E32-T22S 2M

4,000 *1

4,000 *1

3,750

1,000

1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Models for Detection without Background Interference

Sensing
 method

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-speed
 mode

Limited-
 reflective

Flat-view

E32-L16-N 2M

0 to 15

0 to 12

E32-L24S 2M

0 to 4

Side-view

E32-L25L 2M

5.4 to 9 (center 7.2)

Transparent Object Detection (Retro-reflective Models)

Sensing
 method

Feature

Size

Models

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Retro-
 reflective

Film detection

M3

E32-C31 2M + E39-F3R +
 E39-RP37

370

300

---

Square

---

E32-R16 5M

150 to 1,500

Threaded

M6

E32-R21 2M

10 to 370

10 to 250

Hex-shaped

E32-LR11NP 2M +
 E39-RP1

2,020

1,800

1,500

550

Transparent Object Detection (Limited-reflective Models)

Sensing
 method

Feature

Sensing
 direction

Model

Sensing distance (mm)

Giga
 mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Limited-
 reflective

Small size

Flat-view

E32-L24S 2M

0 to 4

Standard

E32-L16-N 2M

0 to 15

0 to 12

Glass substrate
 alignment, 70°C

E32-A08 2M

10 to 20

---

Standard/long-distance

E32-A12 2M

12 to 30

---

Side-view form

Side-view

E32-L25L 2M

5.4 to 9 (center 7.2)

Glass substrate
 mapping, 70°C

Top-view

E32-A09 2M

15 to 38

---

Chemical-resistant, Oil-resistant Models

Sensing
 method

Type

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

Oil-resistant

Right-angle

E32-T11NF 2M

4,000 *1

4,000 *1

4,000 *1

2,200

Chemical/
 oil-resistant

Top-view

E32-T12F 2M

4,000 *1

4,000 *1

4,000 *1

1,600

E32-T11F 2M

4,000 *1

4,000 *1

3,900

1,000

Side-view

E32-T14F 2M

2,100

1,200

750

200

Chemical/
 oil-resistant at
 150°C

Top-view

E32-T51F 2M

4,000 *1

4,000 *1

2,700

700

Reflective

Semiconductors:
 Cleaning,
 developing, and
 etching; 60°C

Top-view

E32-L11FP 5M

8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm),
 19 to 31 mm from center of mounting hole A
 (Recommended sensing distance: 22 mm)

Semiconductors:
 Resist stripping;
 85°C

E32-L11FS 5M

8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm),
 32 to 44 mm from center of mounting hole A
 (Recommended sensing distance: 35 mm)

Chemical/
 oil-resistant

E32-D12F 2M

--- *2

280

190

60

Chemical-
 resistant cable

E32-D11U 2M

1,260

520

360

100

1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
 2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.

Bending-resistant Models

Sensing
 method

Size

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-speed
 mode

Through-beam

1.5 dia.

E32-T22B 2M

1,020

600

330

90

M3

E32-T21 2M

M4

E32-T11 2M

3,750

2,020

1,350

360

Square

32-T25XB 2M

750

450

250

70

Reflective

1.5 dia.

E32-D22B 2M

210

90

60

16

M3

E32-D21 2M

3 dia.

E32-D221B 2M

450

210

130

40

M4

E32-D21B 2M

M6

E32-D11 2M

1,260

520

360

100

Square

E32-D25XB 2M

360

150

90

30

Heat-resistant Models

Sensing
 method

Heat-resistant
 temperature

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

100°C

E32-T51R 2M

2,400

1,200

840

225

150°C

E32-T51 2M

4,000 *1

2,250

1,500

400

200°C

E32-T81R-S 2M

1,500

820

540

140

350°C

E32-T61-S 2M

2,520

1,350

900

240

Reflective

100°C

E32-D51R 2M

1,000

420

280

80

150°C

E32-D51 2M

1,680

670

480

144

200°C

E32-D81R-S 2M

630

270

180

54

300°C

E32-A08H2 2M

10 to 20

---

E32-A09H2 2M

20 to 30 (center 25)

---

350°C

E32-D611-S 2M

630

270

180

54

E32-D61-S 2M

400°C

E32-D73-S 2M

420

180

120

36

1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Area Detection Models

Sensing
 method

Type

Sensing width

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

Area

11 mm

E32-T16PR 2M

4,000 *1

2,550

1,680

440

E32-T16JR 2M

4,000 *1

2,250

1,440

380

30 mm

E32-T16WR 2M

4,000 *1

3,900

2,550

680

Reflective

Array

11 mm

E32-D36P1 2M

1,050

450

300

90

1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Liquid-level Detection Models

Sensing
 method

Tube
 diameter

Feature

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Tube-
 mounting

3.2, 6.4, or
 9.5 dia

Stable
 residual
 quantity
 detection

E32-A01 5M

Applicable tube: Transparent tube with a diameter of 3.2,
 6.4, or 9.5 mm, Recommended wall thickness: 1 mm

8 to 10 dia

Mounting at
 multiple
 levels

E32-L25T 2M

Applicable tube: Transparent tube with a diameter of 8 to
 10 mm, Recommended wall thickness: 1 mm

No
 restrictions

Large tubes

E32-D36T 5M

Applicable tube: Transparent tube (no restrictions on
 diameter)

Liquid contact
 (heat-resistant
 up to 200°C)

---

---

E32-D82F1 4M

Liquid-contact type

Vacuum-resistant Models

Sensing
 method

Heat-resistant
 temperature

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Through-beam

120 °C

E32-T51V 1M

1,080

600

390

100

E32-T51V 1M + E39-F1V

2,000 *1

2,000 *1

2,000 *1

520

200 °C

E32-T84SV 1M

2,000*1

1,420

960

260

*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.

Models for FPD, Semiconductors, and Solar Cells

Sensing
 method

Application

Operating
 temperature

Model

Sensing distance (mm)

Giga mode

Standard
 mode

High-speed
 mode

Super-high-
 speed mode

Limited-
 reflective

Glass presence
 detection

70°C

E32-L16-N 2M

0 to 15

0 to 12

E32-A08 2M

10 to 20

---

Glass substrate
 alignment

300°C

E32-A08H2 3M

70°C

E32-A12 2M

12 to 30

---

Glass substrate
 mapping

E32-A09 2M

15 to 38

---

300°C

E32-A09H2 2M

20 to 30 (center 25)

---

Wet processes:
 Cleaning, Resist
 developing and
 etching

60°C

E32-L11FP 5M

8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm),
 19 to 31 mm from center of mounting hole A
 (Recommended sensing distance: 22 mm)

Wet process:
 Resist stripping

85°C

E32-L11FS 5M

8 to 20 mm from tip of lens (Recommended sensing
 distance: 11 mm),
 32 to 44 mm from center of mounting hole A
 (Recommended sensing distance: 35 mm)

Through-
 beam

Wafer mapping

70°C

E32-A03 2M

4,000 *1

2,670

1,800

500

E32-A03-1 2M

E32-A04 2M

1,920

1,020

670

200

E32-T24SR 2M

4,000 *1

3,300

2,190

580

E32-T24S 2M

4,000 *1

3,900

2,610

700

1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Infrared models

Threaded Models

Sensing
 method

Sensing
 direction

Size

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

Right-angle

M4

E32-T11N 2M

280

190

130

55

Straight

E32-T11R 2M

Reflective

Straight

M3

E32-C31 2M

50

37

25

8.5

M6

E32-D11R 2M

120

90

60

21

E32-CC200 2M

200

150

100

35

Cylindrical Models

Sensing
 method

Size

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

3 dia.

Top-view

E32-T12R 2M

280

190

130

55

Side-view

E32-T14LR 2M

100

75

80

21

Reflective

3 dia.

Top-view

E32-D32L 2M

100

75

50

17

Flat Models

Sensing
 method

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

Top-view

E32-T15XR 2M

280

190

130

55

Side-view

E32-T15YR 2M

100

75

80

21

Flat-view

E32-T15ZR 2M

Reflective

Top-view

E32-D15XR 2M

120

90

60

21

Side-view

E32-D15YR 2M

28

20

13

5

Flat-view

E32-D15ZR 2M

Sleeve Models

Sensing
 method

Sensing
 direction

Model

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-
 beam

Top-view

E32-TC200BR 2M

280

190

130

55

Reflective

Top-view

E32-DC200BR 2M

120

90

60

21

High-power Beam Models

Type

Sensing
 direction

Aperture
 angle

Models

Sensing distance (mm)

Giga mode

Standard mode

High-speed
 mode

Super-high-
 speed mode

Through-beam
 models with
 integrated lens

Side-view

30°

E32-T14 2M

1800

1200

820

360