Smart Sensors (Laser Displacement & Measurement Sensors)
ZX-L-N
A Host of Smart Functions Inside a Compact Body with a Full Range of Laser Types
Sensor Heads (Reflective)
Model |
ZX-LD40 |
ZX-LD100 |
ZX-LD300 |
ZX-LD30V |
ZX-LD40L |
ZX-LD100L |
ZX-LD300L |
ZX-LD30VL |
Optical system |
Diffuse reflective |
Regular |
Diffuse reflective |
Regular |
||||
Light source |
Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max. |
|||||||
EN class 2, FDA class II |
||||||||
Measurement |
40 mm |
100 mm |
300 mm |
30 mm |
40 mm |
100 mm |
300 mm |
30 mm |
Measurement |
± 10 mm |
± 40 mm |
± 200 mm |
± 2 mm |
± 10 mm |
± 40 mm |
± 200 mm |
± 2 mm |
Beam shape |
Spot |
Line |
||||||
Beam size*1 |
50-μm dia. |
100-μm dia. |
300-μm dia. |
75-μm dia. |
75 μm x 2 mm |
150 μm x 2 mm |
450 μm x 2 mm |
100 μm x 1.8 mm |
Resolution*2 |
2 μm |
16 μm |
300 μm |
0.25 μm |
2 μm |
16 μm |
300 μm |
0.25 μm |
Linearity*3 |
± 0.2% FS |
± 0.2% FS |
± 2% FS |
± 0.2% FS |
± 0.2% FS |
± 0.2% FS |
± 2% FS |
± 0.2% FS |
Temperature |
± 0.03% FS/°C (Except for ZX-LD300 and ZX-LD300L, which are ± 0.1% FS/°C.) |
|||||||
Ambient |
Incandescent lamp: 3,000 l× max. (on light receiving side) |
|||||||
Ambient |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) |
|||||||
Ambient |
Operating and storage: 35% to 85% (with no condensation) |
|||||||
Insulation |
20 MΩ min. at 500 VDC |
|||||||
Dielectric |
1,000 VAC, 50/60 Hz for 1 min |
|||||||
Vibration |
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions |
|||||||
Shock |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
|||||||
Degree of |
IEC60529, IP50 |
IEC60529, IP40 |
IEC60529, IP50 |
IEC60529, IP40 |
||||
Connection |
Connector relay (standard cable length: 500 mm) |
|||||||
Weight |
Approx. 150 g |
Approx. 250 g |
Approx. 150 g |
Approx. 250 g |
||||
Materials |
Case: PBT |
Case and cover: Aluminum, |
Case: PBT |
Case and cover: Aluminum, |
||||
Accessories |
Instruction sheet, Laser warning label (English) |
1. Beam size: The beam size is defined by 1/e2 (13.5%) of the strength of the beam at the beam center (measured value). Incorrect detection may occur if there is light leakage outside the defined spot and the material around the sensing object is more reflective than the sensing object.
2. Resolution: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured with the standard reference object (white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
3. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
4. Temperature characteristic: The temperature characteristic is measured at the measurement point with the Sensor and reference object (OMRON's standard reference object) secured with an aluminum jig.
Note: Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
Sensor Heads (Through-beam)
Model |
ZX-LT001 |
ZX-LT005 |
ZX-LT010 |
ZX-LT030 |
||
Optical system |
Through-beam |
|||||
Light source |
Visible-light semiconductor laser with a wavelength of 650 nm |
|||||
EN class 1, FDA class II |
||||||
Light source (wave length) |
Maximum |
0.2 mW max. |
0.35 mW max. |
0.2 mW max. |
||
Measurement width |
1-mm dia. |
1- to 2.5-mm dia. |
5 mm |
10 mm |
30 mm |
|
Measurement distance |
0 to 500 mm |
500 to 2,000 mm |
0 to 500 mm |
|||
Minimum sensing object |
8-μm dia. (opaque) |
8- to 50-μm dia. (opaque) |
0.05-mm dia. (opaque) |
0.1-mm dia. (opaque) |
0.3-mm dia. (opaque) |
|
Resolution*1 |
4 μm*2 |
--- |
4 μm*3 |
12 μm*4 |
||
Temperature |
±0.2% FS/°C |
±0.3% FS/°C |
||||
Ambient illumination |
Incandescent lamp: 10,000 l× max. (on light-receiving side) |
|||||
Ambient temperature |
Operating: 0 to 50°C, Storage: -25 to 70°C (with no icing or condensation) |
|||||
Ambient humidity |
Operating: 35% to 85% (with no condensation) |
|||||
Degree of protection |
IEC60529, IP40 |
|||||
Connection method |
Connector relay (standard cable length: 500 mm) |
|||||
Weight (packed state) |
Approx. 220 g |
Approx. 450 g |
||||
Cable length |
Extendable up to 10 m with special extension cable. |
|||||
Materials |
Case |
Polyether imide |
Zinc die-cast |
|||
Cover |
Polycarbonate |
|||||
Front filter |
Glass |
|||||
Tightening torque |
0.3 Nm max. |
|||||
Accessories |
Instruction sheet, Sensor Head-Amplifier Connection Cable |
|||||
Optical axis adjustment seal |
Mounting Bracket |
1. This value is obtained by converting the deviation (±3σ) in the linear output that results when the sensor head is connected to the amplifier unit, into the measurement width.
2. For an average count of 64. The value is 5 μm for an average count of 32. This is the value that results when a minimum sensing object blocks the light near the center of the 1-mm measurement width.
3. For an average count of 64. The value is 5 μm for an average count of 32.
4. For an average count of 64. The value is 15 μm for an average count of 32.
Amplifier Units
Model |
ZX-LDA11-N |
ZX-LDA41-N |
Measurement period *1 |
150 μs |
|
Possible average count |
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 |
|
Temperature characteristic |
When connected to a Reflective Sensor Head: 0.01% FS/°C, |
|
Linear output *2 |
Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω |
|
Judgement outputs |
NPN open-collector outputs, 30 VDC, 50 mA max. |
PNP open-collector outputs, 30 VDC, 50 mA max. |
Laser OFF input, |
ON: Short-circuited with 0-V terminal or 1.5 V or less |
ON: Supply voltage short-circuited or supply voltage |
Functions |
Measurement value display, present value/set value/light level/resolution display, scaling, display reverse, |
|
Indications |
Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment |
|
Power supply voltage |
12 to 24 VDC ± 10%, Ripple (p-p): 10% max. |
|
Current consumption |
140 mA max. with power supply voltage of 24 VDC (with Sensor connected) |
|
Ambient temperature |
Operating and storage: 0 to 50°C (with no icing or condensation) |
|
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
|
Insulation resistance |
20 MΩ min. at 500 VDC |
|
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
|
Vibration resistance |
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions |
|
Shock resistance |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
|
Connection method |
Prewired (standard cable length: 2 m) |
|
Weight (packed state) |
Approx. 350 g |
|
Materials |
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate |
|
Accessories |
Instruction sheet |
1. The response time for the first linear output or judgment output is calculated as follows (with fixed sensitivity): Measurement period × (Average count setting + 1). The response time for the second and later outputs is the measurement period specified in the table.
2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit (ZX-CAL2) is required.
Calculating Unit
Model |
ZX-CAL2 |
Applicable Amplifier Units |
ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41 |
Current consumption |
12 mA max. (supplied from the Smart Sensor Amplifier Unit) |
Ambient temperature |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
Connection method |
Connector |
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
Insulation resistance |
100 MΩ (at 500 VDC) |
Vibration resistance (destructive) |
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions |
Shock resistance (destructive) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
Materials |
Display: Acrylic, Case: ABS resin |
Weight (packed state) |
Approx. 50 g |
ZX-series Communications Interface Unit
Item |
ZX-SF11 |
|
Current consumption |
60 mA max. (supplied by the Amplifier Unit) |
|
Applicable Amplifier Units |
ZX Series |
|
Applicable Amplifier Unit |
ZX-LDA[]1-N Ver. 2.100 or higher |
|
Max. No. of Amplifier Units |
5 (max. 2 with calculating unit) |
|
Commu- |
Communications port |
RS-232C port (9-pin D-Sub Connector) |
Communications |
CompoWay/F* |
|
Baud rate |
38,400 bps |
|
Data configuration |
Data bits: 8, Parity: none, Start bits: 1, Stop bits: 1, Flow control: none |
|
Indicators |
Power supply: green, Sensor communications: green, Sensor communications |
|
Protective circuits |
Reverse polarity protection |
|
Ambient temperature |
Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) |
|
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
|
Insulation resistance |
20 MΩ min. (at 500 VDC) |
|
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max. |
|
Materials |
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate |
|
Accessories |
Instruction sheet, 2 clamps |