Smart Sensors (Laser Displacement & Measurement Sensors)

ZX-L-N

A Host of Smart Functions Inside a Compact Body with a Full Range of Laser Types

Sensor Heads (Reflective)

Model

ZX-LD40

ZX-LD100

ZX-LD300

ZX-LD30V

ZX-LD40L

ZX-LD100L

ZX-LD300L

ZX-LD30VL

Optical system

Diffuse reflective

Regular
 reflective

Diffuse reflective

Regular
 reflective

Light source
 (wave length)

Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max.

EN class 2, FDA class II

Measurement
 point

40 mm

100 mm

300 mm

30 mm

40 mm

100 mm

300 mm

30 mm

Measurement
 range

± 10 mm

± 40 mm

± 200 mm

± 2 mm

± 10 mm

± 40 mm

± 200 mm

± 2 mm

Beam shape

Spot

Line

Beam size*1

50-μm dia.

100-μm dia.

300-μm dia.

75-μm dia.

75 μm x 2 mm

150 μm x 2 mm

450 μm x 2 mm

100 μm x 1.8 mm

Resolution*2

2 μm

16 μm

300 μm

0.25 μm

2 μm

16 μm

300 μm

0.25 μm

Linearity*3

± 0.2% FS
 (entire range)

± 0.2% FS
 (80 to 120 mm)

± 2% FS
 (200 to 400 mm)

± 0.2% FS
 (entire range)

± 0.2% FS
 (32 to 48 mm)

± 0.2% FS
 (80 to 120 mm)

± 2% FS
 (200 to 400 mm)

± 0.2% FS
 (entire range)

Temperature
 characteristic*4

± 0.03% FS/°C (Except for ZX-LD300 and ZX-LD300L, which are ± 0.1% FS/°C.)

Ambient
 temperature

Incandescent lamp: 3,000 l× max. (on light receiving side)

Ambient
 illumination

Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)

Ambient
 humidity

Operating and storage: 35% to 85% (with no condensation)

Insulation
 resistance

20 MΩ min. at 500 VDC

Dielectric
 strength

1,000 VAC, 50/60 Hz for 1 min

Vibration
 resistance
 (destruction)

10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions

Shock
 resistance
 (destruction)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Degree of
 protection

IEC60529, IP50

IEC60529, IP40

IEC60529, IP50

IEC60529, IP40

Connection
 method

Connector relay (standard cable length: 500 mm)

Weight
 (packed state)

Approx. 150 g

Approx. 250 g

Approx. 150 g

Approx. 250 g

Materials

Case: PBT
 (polybutylene terephthalate),
 Cover: Aluminum,
 Lens: Glass

Case and cover: Aluminum,
 Lens: Glass

Case: PBT
 (polybutylene terephthalate),
 Cover: Aluminum,
 Lens: Glass

Case and cover: Aluminum,
 Lens: Glass

Accessories

Instruction sheet, Laser warning label (English)

1. Beam size: The beam size is defined by 1/e2 (13.5%) of the strength of the beam at the beam center (measured value). Incorrect detection may occur if there is light leakage outside the defined spot and the material around the sensing object is more reflective than the sensing object.
 2. Resolution: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured with the standard reference object (white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
 3. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
 4. Temperature characteristic: The temperature characteristic is measured at the measurement point with the Sensor and reference object (OMRON's standard reference object) secured with an aluminum jig.
 Note: Highly reflective objects can result in incorrect detection by causing out-of-range measurements.

Sensor Heads (Through-beam)

Model

ZX-LT001

ZX-LT005

ZX-LT010

ZX-LT030

Optical system

Through-beam

Light source
 (wave length)

Visible-light semiconductor laser with a wavelength of 650 nm

EN class 1, FDA class II

Light source (wave length)

Maximum
 output

0.2 mW max.

0.35 mW max.

0.2 mW max.

Measurement width

1-mm dia.

1- to 2.5-mm dia.

5 mm

10 mm

30 mm

Measurement distance

0 to 500 mm

500 to 2,000 mm

0 to 500 mm

Minimum sensing object

8-μm dia. (opaque)

8- to 50-μm dia. (opaque)

0.05-mm dia. (opaque)

0.1-mm dia. (opaque)

0.3-mm dia. (opaque)

Resolution*1

4 μm*2

---

4 μm*3

12 μm*4

Temperature
 characteristic

±0.2% FS/°C

±0.3% FS/°C

Ambient illumination

Incandescent lamp: 10,000 l× max. (on light-receiving side)

Ambient temperature

Operating: 0 to 50°C, Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity

Operating: 35% to 85% (with no condensation)

Degree of protection

IEC60529, IP40

Connection method

Connector relay (standard cable length: 500 mm)

Weight (packed state)

Approx. 220 g

Approx. 450 g

Cable length

Extendable up to 10 m with special extension cable.

Materials

Case

Polyether imide

Zinc die-cast

Cover

Polycarbonate

Front filter

Glass

Tightening torque

0.3 Nm max.

Accessories

Instruction sheet, Sensor Head-Amplifier Connection Cable

Optical axis adjustment seal

Mounting Bracket

1. This value is obtained by converting the deviation (±3σ) in the linear output that results when the sensor head is connected to the amplifier unit, into the measurement width.
 2. For an average count of 64. The value is 5 μm for an average count of 32. This is the value that results when a minimum sensing object blocks the light near the center of the 1-mm  measurement width.
 3. For an average count of 64. The value is 5 μm for an average count of 32.
 4. For an average count of 64. The value is 15 μm for an average count of 32.

Amplifier Units

Model

ZX-LDA11-N

ZX-LDA41-N 

Measurement period *1

150 μs

Possible average count
 settings

1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096

Temperature characteristic

When connected to a Reflective Sensor Head: 0.01% FS/°C,
 When connected to a Through-beam Sensor Head: 0.1% FS/°C

Linear output *2

Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω
 Voltage output: ±4 V (± 5 V, 1 to 5 V *3), Output impedance: 100 Ω

Judgement outputs
 (3 outputs:
 HIGH/PASS/LOW) *1

NPN open-collector outputs, 30 VDC, 50 mA max.
 Residual voltage: 1.2 V max.

PNP open-collector outputs, 30 VDC, 50 mA max.
 Residual voltage: 2 V max.

Laser OFF input,
 zero reset input,
 timing input, reset input

ON: Short-circuited with 0-V terminal or 1.5 V or less
 OFF: Open
 (leakage current: 0.1 mA max.)

ON: Supply voltage short-circuited or supply voltage
 within 1.5 V
 OFF: Open (leakage current: 0.1 mA max.)

Functions

Measurement value display, present value/set value/light level/resolution display, scaling, display reverse,
 display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to-
 peak hold, self-peak hold, self-bottom hold, average hold, delay hold, intensity mode, zero reset, initial reset,
 ON-delay timer, OFF-delay timer, one-shot timer, deviation, previous value comparison, sensitivity adjustment,
 keep/clamp switch, direct threshold value setting, position teaching, 2-point teaching, automatic teaching,
 hysteresis width setting, timing inputs, reset input, monitor focus, linear output compensation, (A-B)
 calculations14, (A+B) calculations*4, mutual interference*4, laser deterioration detection, zero reset memory,
 zero reset display, key lock

Indications

Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment
 subdisplay (yellow), laser ON (green), zero reset (green), enable (green)

Power supply voltage

12 to 24 VDC ± 10%, Ripple (p-p): 10% max.

Current consumption

140 mA max. with power supply voltage of 24 VDC (with Sensor connected)

Ambient temperature

Operating and storage: 0 to 50°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Vibration resistance
 (destruction)

10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions

Shock resistance
 (destruction)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Connection method

Prewired (standard cable length: 2 m)

Weight (packed state)

Approx. 350 g

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Accessories

Instruction sheet

1. The response time for the first linear output or judgment output is calculated as follows (with fixed sensitivity): Measurement period × (Average count setting + 1). The response time for the second and later outputs is the measurement period specified in the table.
 2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
 3. Setting is possible via the monitor focus function.
 4. A Calculating Unit (ZX-CAL2) is required.

Calculating Unit

Model

ZX-CAL2

Applicable Amplifier Units

ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41

Current consumption

12 mA max. (supplied from the Smart Sensor Amplifier Unit)

Ambient temperature

Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Connection method

Connector

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Insulation resistance

100 MΩ (at 500 VDC)

Vibration resistance (destructive)

10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions

Shock resistance (destructive)

300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)

Materials

Display: Acrylic, Case: ABS resin

Weight (packed state)

Approx. 50 g

ZX-series Communications Interface Unit

Item

ZX-SF11

Current consumption

60 mA max. (supplied by the Amplifier Unit)

Applicable Amplifier Units

ZX Series

Applicable Amplifier Unit
 versions

ZX-LDA[]1-N Ver. 2.100 or higher
 ZX-EDA[]1 Ver. 1.100 or higher
 ZX-TDA[]1 Ver. 1.000 or higher

Max. No. of Amplifier Units

5 (max. 2 with calculating unit)

Commu-
 nications
 functions

Communications port

RS-232C port (9-pin D-Sub Connector)

Communications
 protocol

CompoWay/F*

Baud rate

38,400 bps

Data configuration

Data bits: 8, Parity: none, Start bits: 1, Stop bits: 1, Flow control: none

Indicators

Power supply: green, Sensor communications: green, Sensor communications
 error: red,
 External terminal communications: green, External terminal communications
 error: red

Protective circuits

Reverse polarity protection

Ambient temperature

Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max.

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Accessories

Instruction sheet, 2 clamps