Amplifier Units
Model |
ZX-TDA11 |
ZX-TDA41 |
Measurement period |
1 ms |
|
Possible average count |
1, 16, 32, 64, 128, 256, 512, or 1,024 |
|
Linear output *2 |
Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω |
|
Judgement outputs |
NPN open-collector outputs, 30 VDC, 30 |
PNP open-collector outputs, 30 VDC, 30 |
Zero reset input, timing |
ON: Short-circuited with 0-V terminal or |
ON: Supply voltage short-circuited or |
Function |
Measurement value display, Present value/set value/output value display, Display |
|
Indicators |
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main |
|
Power supply voltage |
12 to 24 VDC ±10%, Ripple (p-p): 10% max. |
|
Current consumption |
140 mA max. (with Sensor connected), For 24-VDC power supply voltage: 140 mA |
|
Ambient temperature |
Operating and storage: 0 to 50°C (with no icing or condensation) |
|
Temperature characteristic |
0.03% F.S./°C |
|
Connection method |
Prewired (standard cable length: 2 m) |
|
Weight (packed state) |
Approx. 350 g |
|
Materials |
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate |
1. The response speed of the linear output is calculated as the measurement period × (average count setting + 1). The response speed of the judgement outputs is calculated as the measurement period × (average count setting + 1).
2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit (ZX-CAL2) is required.
Sensor Heads
Model |
ZX-TDS01T |
ZX-TDS04T |
ZX-TDS04T-L |
|
Measurement range |
1 mm |
4 mm |
||
Maximum actuator travel distance |
Approx. 1.5 mm |
Approx. 5 mm |
||
Resolution *1 |
0.1 μm |
|||
Linearity *2 |
0.5% F.S. |
|||
Operating force *3 |
Approx. 0.7 N |
Approx. 0.25 N |
||
Degree of protection (Sensor Head) |
IEC60529, IP67 |
IEC60529, IP54 |
||
Mechanical durability |
10,000,000 operations min. |
|||
Ambient temperature |
Operating: 0°C to 50°C (with no icing or condensation) |
|||
Ambient humidity |
Operating and storage: 35% to 85% (with no icing or condensation) |
|||
Temperature |
Sensor Head |
0.03% F.S./°C |
||
Preamplifier |
0.01% F.S./°C |
|||
Weight (packed state) |
Approx. 100 g |
|||
Materials |
Sensor Head |
Stainless steel |
||
Preamplifier |
Polycarbonate |
|||
Accessories |
Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1) |
1. The resolution is given as the minimum value that can be read when a ZX-TDA[]1 Amplifier Unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
2. The linearity is given as the error in an ideal straight line displacement output.
3. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
4. These figures are representative values that apply for the mid-point of the measurement range.
Sensor (Long-range Type)
Model |
ZX-TDS10T |
ZX-TDS10T-V |
ZX-TDS10T-L |
ZX-TDS10T-VL |
|
Vacuum retract (VR) and air push |
No |
VR |
No |
VR/AP |
|
Measurement range |
10 mm |
||||
Maximum actuator travel distance |
10.5 mm |
||||
Resolution *1 *5 |
0.4 μm |
||||
Linearity *2 *5 |
±0.5% FS |
||||
Operating force *3 |
Approx. 0.7 N |
Approx. 0.6 N |
Approx. 0.065 N |
Approx. 0.09 to |
|
Air pressure |
Vacuum retracting |
--- |
-0.55 to |
--- |
-0.22 to -0.5 (bar) |
Air push |
--- |
0.125 to 2 (bar) |
|||
Degree of |
Sensor Head |
IP65 |
IP50 |
||
Preamplifier |
IP40 |
||||
Mechanical durability |
10,000,000 operations min. |
||||
Ambient temperature |
Operating: 0 to 50°C (with no icing or condensation), |
||||
Ambient humidity |
Operating and storage: 35% to 85% (with no icing or condensation) |
||||
Temperature |
Sensor Head |
±0.01% F.S./°C |
|||
Preamplifier |
±0.01% F.S./°C |
||||
Vibration resistance |
0.35-mm single amplitude at 10 to 55 Hz for 50 min each in the X, Y, and |
||||
Shock resistance |
150 m/S2 3 times each in 6 directions (up/down, left/right, and forward/backward) |
||||
Connection method |
Prewired connector (2 m from the Sensor Head to the Preamplifier, 0.2 m |
||||
Weight (packed state) |
Approx. 100 g |
||||
Materials |
Sensor Head |
Stainless steel |
|||
Rubber sleeve |
Viton |
None |
|||
Preamplifier |
Polycarbonate |
||||
Mounting Brackets |
Stainless steel |
Polyamide |
|||
Accessories |
Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1), Right- |
1. The resolution indicates the variation (±3 σ) in the linear output (voltage output) when a ZX-TDA[]1 Amplifier Unit is connected. This value is taken 30 minutes after turning ON the power with the average number of operations set to 1,024. The minimum value that can be read is 1 μm.
2. The linearity is given as the error in an ideal straight line displacement output.
3. These figures are representative values that apply for the mid-point of the measurement range when the Actuator provided is secured facing downward. - ZX-TDS10T and ZX-TDS10T-V: The operating force will be reduced if the Actuator is secured facing horizontally or upward.
- ZX-TDS10T-L and ZX-TDS10T-VL: The actuator can be installed only facing downward.
4. These figures are representative values that apply for the mid-point of the measurement range.
5. These values were measured at an ambient temperature of 23°C.
6. The ZX-TDS10T comes with a Right-angle Adapter.