Smart Sensors High-Precision Contact Type

ZX-T

The Smart Answer to High-precision Measuring Applications that Were Difficult with Non-contact Types

Amplifier Units

Model

ZX-TDA11

ZX-TDA41

Measurement period

1 ms

Possible average count
 settings *1

1, 16, 32, 64, 128, 256, 512, or 1,024

Linear output *2

Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω
 Voltage output: ±4 V (±5 V, 1 to 5 V *3), Output impedance: 100 Ω

Judgement outputs
 (3 outputs: HIGH/PASS/LOW)

NPN open-collector outputs, 30 VDC, 30
 mA max.
 Residual voltage: 1.2 V max.

PNP open-collector outputs, 30 VDC, 30
 mA max.
 Residual voltage: 2 V max.

Zero reset input, timing
 input, reset input, judgement
 output hold input

ON: Short-circuited with 0-V terminal or
 1.5 V or less
 OFF: Open (leakage current: 0.1 mA max.)

ON: Supply voltage short-circuited or
 supply voltage of 1.5 V or less
 OFF: Open (leakage current: 0.1 mA max.)

Function

Measurement value display, Present value/set value/output value display, Display
 reverse, ECO mode, Number of display digit changes, Sample hold, Peak hold, Bottom
 hold, peak-to-peak hold, Self-peak hold, Self-bottom hold, Zero reset, Initial reset,
 Direct threshold value setting, Position teaching, Hysteresis width setting, Timing
 inputs, Reset input, Judgement output hold input, (A-B) calculations *4, (A+B)
 calculations *4, Sensor disconnection detection, Zero reset memory, Function lock,
 Non-measurement setting, Clamp value setting, Scale inversion, Zero reset
 indicator, Span adjustment, Warming-up display, Pressing force alarm

Indicators

Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main
 digital display (red), 7-segment sub-digital display (yellow), power ON (green), zero
 reset (green), enable (green)

Power supply voltage

12 to 24 VDC ±10%, Ripple (p-p): 10% max.

Current consumption

140 mA max. (with Sensor connected), For 24-VDC power supply voltage: 140 mA
 max. (with Sensor connected)

Ambient temperature

Operating and storage: 0 to 50°C (with no icing or condensation)

Temperature characteristic

0.03% F.S./°C

Connection method

Prewired (standard cable length: 2 m)

Weight (packed state)

Approx. 350 g

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

1. The response speed of the linear output is calculated as the measurement period × (average count setting + 1). The response speed of the judgement outputs is calculated as the measurement period × (average count setting + 1).
 2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
 3. Setting is possible via the monitor focus function.
 4. A Calculating Unit (ZX-CAL2) is required.

Sensor Heads

Model

ZX-TDS01T

ZX-TDS04T

ZX-TDS04T-L

Measurement range

1 mm

4 mm

Maximum actuator travel distance

Approx. 1.5 mm

Approx. 5 mm

Resolution *1

0.1 μm

Linearity *2

0.5% F.S.

Operating force *3

Approx. 0.7 N

Approx. 0.25 N

Degree of protection (Sensor Head)

IEC60529, IP67

IEC60529, IP54

Mechanical durability

10,000,000 operations min.

Ambient temperature

Operating: 0°C to 50°C (with no icing or condensation)
 Storage: -15°C to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no icing or condensation)

Temperature
 characteristic *4

Sensor Head

0.03% F.S./°C

Preamplifier

0.01% F.S./°C

Weight (packed state)

Approx. 100 g

Materials

Sensor Head

Stainless steel

Preamplifier

Polycarbonate

Accessories

Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1)

1. The resolution is given as the minimum value that can be read when a ZX-TDA[]1 Amplifier Unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
 2. The linearity is given as the error in an ideal straight line displacement output.
 3. These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
 4. These figures are representative values that apply for the mid-point of the measurement range.

Sensor (Long-range Type)

Model

ZX-TDS10T

ZX-TDS10T-V

ZX-TDS10T-L

ZX-TDS10T-VL

Vacuum retract (VR) and air push
 (AP) compatible

No

VR

No

VR/AP

Measurement range

10 mm

Maximum actuator travel distance

10.5 mm

Resolution *1 *5

0.4 μm

Linearity *2 *5

±0.5% FS

Operating force *3

Approx. 0.7 N

Approx. 0.6 N

Approx. 0.065 N

Approx. 0.09 to
 1.41 N

Air pressure

Vacuum retracting

---

-0.55 to
 -0.70 (bar)

---

-0.22 to -0.5 (bar)

Air push

---

0.125 to 2 (bar)

Degree of
 protection

Sensor Head

IP65

IP50

Preamplifier

IP40

Mechanical durability

10,000,000 operations min.

Ambient temperature

Operating: 0 to 50°C (with no icing or condensation),
 Storage: -10 to 60°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no icing or condensation)

Temperature
 characteristic
 *4

Sensor Head

±0.01% F.S./°C

Preamplifier

±0.01% F.S./°C

Vibration resistance

0.35-mm single amplitude at 10 to 55 Hz for 50 min each in the X, Y, and
 Z directions

Shock resistance

150 m/S2 3 times each in 6 directions (up/down, left/right, and forward/backward)

Connection method

Prewired connector (2 m from the Sensor Head to the Preamplifier, 0.2 m
 from the Preamplifier to the connector)

Weight (packed state)

Approx. 100 g

Materials

Sensor Head

Stainless steel

Rubber sleeve

Viton

None

Preamplifier

Polycarbonate

Mounting Brackets

Stainless steel

Polyamide

Accessories

Instruction manual, Preamplifier Mounting Brackets (ZX-XBT1), Right-
 angle Adapter *6

1. The resolution indicates the variation (±3 σ) in the linear output (voltage output) when a ZX-TDA[]1 Amplifier Unit is connected. This value is taken 30 minutes after turning ON the power with the average number of operations set to 1,024. The minimum value that can be read is 1 μm.
 2. The linearity is given as the error in an ideal straight line displacement output.
 3. These figures are representative values that apply for the mid-point of the measurement range when the Actuator provided is secured facing downward. - ZX-TDS10T and ZX-TDS10T-V: The operating force will be reduced if the Actuator is secured facing horizontally or upward.
 - ZX-TDS10T-L and ZX-TDS10T-VL: The actuator can be installed only facing downward.
 4. These figures are representative values that apply for the mid-point of the measurement range.
 5. These values were measured at an ambient temperature of 23°C.
 6. The ZX-TDS10T comes with a Right-angle Adapter.