Smart Sensor Laser Sensor with Built-in Amplifie
ZX1
A CMOS Laser Sensor That’s Optimum for Simple Measurements
Model |
NPN output |
ZX1-LD50A61 |
ZX1-LD100A61 |
ZX1-LD300A61 |
ZX1-LD600A61 |
PNP output |
ZX1-LD50A81 |
ZX1-LD100A81 |
ZX1-LD300A81 |
ZX1-LD600A81 |
|
Measurement range |
50 ± 10 mm |
100 ± 35 mm |
300 ± 150 mm |
600 ± 400 mm |
|
Light source (wave length) |
Visible-light semiconductor laser |
||||
Spot diameter (typical) |
0.17 mm dia. |
0.33 mm dia. |
0.52 mm dia. |
0.56 mm dia. |
|
Power consumption |
2,500 mW max. (105 mA max. at 24 VDC, 210 mA max. at 12 VDC) |
||||
Current consumption |
250 mA max. (at power supply voltage 10 VDC) |
||||
Control output |
Load power supply voltage: 30 VDC max., Load current: 100 mA max. |
||||
Analog output |
Current output: 4 to 20 mA, maximum load resistance: 300 Ω |
||||
Functions |
Smart tuning, keep function, scaling setting, background removal, OFF-delay timer, |
||||
Indicators |
Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator |
||||
Response |
Judgment output |
Super-high-speed (SHS) Mode: 1 ms |
|||
Laser OFF input |
200 ms max. |
||||
Zero reset input |
200 ms max. |
||||
Temperature characteristic *3 |
0.03% F.S./°C |
0.04% F.S./°C |
|||
Linearity *4 |
±0.15% F.S. |
±0.25% F.S. |
±0.25% F.S. |
||
Resolution *5 |
2 μm |
7 μm |
30 μm |
80 μm |
|
Ambient illumination |
Illumination on received light surface: |
Illumination on received light surface: |
|||
Ambient temperature |
Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation) |
||||
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
||||
Dielectric strength |
1,000 VAC, 50/60 Hz, 1 minute |
||||
Vibration resistance (destruction) |
10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions |
||||
Shock resistance (destruction) |
500 m/s2 3 times each in X, Y, and Z directions |
||||
Degree of protection *6 |
IEC 60529, IP67 |
||||
Connection method *7 |
Pre-wired model (Standard cable length: 2 m, 5 m) |
||||
Weight |
Pre-wired models (2 m) |
Approx. 240 g/Approx. 180 g |
Approx. 270 g/Approx. 210 g |
||
Pre-wired models (5 m) |
Approx. 450 g/Approx. 330 g |
Approx. 480 g/Approx. 360 g |
|||
Pre-wired connector |
Approx. 170 g/Approx. 110 g |
Approx. 200 g/Approx. 140 g |
|||
Materials |
Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable: |
||||
Accessories |
Instruction sheet and Laser warning label (English) |
Note: 1. False detection outside the measurement range can occur in the case of an object with high reflectance.
2. Refer to the below for the ratings and specifications of Sensors with Class 1 lasers.
1. Classified as Class 2 by IEC60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50.
CDRH registration has been completed. (Center for Devices and Radiological Health) (Accession Number: 1210041)
2. Spot diameter: Defined as 1/e2 (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the
target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
*3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is
secured by an aluminum jig. (Measured at the measurement center distance)
*4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring
Omron’s standard target object (white ceramic) at a temperature of 25 °C.
Linearity and measured value may vary depending on target object.
*5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart
Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.
*6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected.
*7. Use a Pre-wired Connector Model together with an Extension Cable (10 m or 20 m).
Ratings and Specifications of Sensors with Class 1 lasers (ZX1-LD[]L)
The ratings and specifications that are different from those of the Sensors with Class 2 lasers are given below.
Model |
ZX1-LD50A61L/ZX1-LD50A81L |
ZX1-LD300A61L/ZX1-LD300A81L |
FDA Class |
Class1 0.24mW max. |
|
IEC/EN Class |
Class1 0.24mW max. |
|
Functions |
No scaling setting |
|
Ambient illumination |
Illumination on received light surface 5,000 lx |
Illumination on received light surface 2,500 lx |
Connection method |
Pre-wired model (2 m) |
|
Accessories |
Instruction sheet and Explanatory label (English), FDA certification label |
Accession Number: 1210041