Special-purpose Basic Switch
DZ
DPDT Basic Switch for Two Independent Circuit Control
Ratings
Rated voltage |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
125 VAC |
10 |
2 |
1 |
6 |
3 |
1.5 |
||
8 VDC |
10 |
3 |
1.5 |
6 |
5 |
2.5 |
||
0.5 |
0.05 |
|||||||
Note: 1. The above values are for steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The ratings values apply under the following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Characteristics
Operating speed |
0.1 mm to 1 m/s *1 |
|
|
Operating frequency |
Mechanical |
240 operations/min |
|
Electrical |
20 operations/min |
|
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
|
Contact resistance |
15 mΩ max. (initial value) |
|
|
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals |
||
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *2 |
|
Shock resistance |
Destruction |
1,000 m/s2 max. |
|
Malfunction |
300 m/s2 max. *1 *2 |
|
|
Durability |
Mechanical |
1,000,000 operations min. |
|
Electrical |
500,000 operations min. |
|
|
Degree of protection |
IP00 |
|
|
Degree of protection against electric shock |
Class I |
||
Proof tracking index (PTI) |
175 |
|
|
Ambient operating temperature |
-25°C to 80°C (with no icing) |
|
|
Ambient operating humidity |
35% to 85%RH |
|
|
Weight |
Approx. 30 to 50 g |
|
1. The values are for pin plunger models. (Contact your OMRON representative for other models.)
2. Malfunction: 1 ms max.
Contact Specifications
Contacts |
Material |
Silver alloy |
Gap (standard value) |
0.5 mm |
|
Inrush current |
NC |
30 A max. |
NO |
15 A max. |