Product Category

DZ

Special-purpose Basic Switch

DZ

DPDT Basic Switch for Two Independent Circuit Control

Ratings

Rated voltage

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
 250 VAC

10
 10

2
 1.5

1
 0.7

6
 4

3
 2

1.5
 1

8 VDC
 14 VDC
 30 VDC
 125 VAC
 250 VDC

10
 10
 10
 0.5
 0.25

3
 3
 3

1.5
 1.5
 1.5

6
 6
 4
 0.05
 0.03

5
 5
 3

2.5
 2.5
 1.5

0.5
 0.25

0.05
 0.03










Note: 1. The above values are for steady-state current.
            2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
            3. Lamp load has an inrush current of 10 times the steady-state current.
            4. Motor load has an inrush current of 6 times the steady-state current.
            5. The ratings values apply under the following test conditions:
                 (1) Ambient temperature: 20±2°C
                 (2) Ambient humidity: 65±5%RH
                 (3) Operating frequency: 20 operations/min

Characteristics

Operating speed

0.1 mm to 1 m/s *1

 

Operating frequency

Mechanical

240 operations/min

 

Electrical

20 operations/min

 

Insulation resistance

100 MΩ min. (at 500 VDC)

 

Contact resistance

15 mΩ max. (initial value)

 

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal part, and between current-carrying metal part and ground and between switches





Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *2

 

Shock resistance

Destruction

1,000 m/s2 max.

 

Malfunction

300 m/s2 max. *1 *2

 

Durability

Mechanical

1,000,000 operations min.

 

Electrical

500,000 operations min.

 

Degree of protection

IP00

 

Degree of protection against electric shock

Class I



Proof tracking index (PTI)

175

 

Ambient operating temperature

-25°C to 80°C (with no icing)

 

Ambient operating humidity

35% to 85%RH

 

Weight

Approx. 30 to 50 g

 

1. The values are for pin plunger models. (Contact your OMRON representative for other models.)
 2. Malfunction: 1 ms max. 

Contact Specifications

Contacts

Material

Silver alloy

Gap (standard value)

0.5 mm

Inrush current

NC

30 A max.

NO

15 A max.