Pushbutton Switch (Cylindrical 22/25-dia.)
A22
Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring)
Model Number Structure
Model Number Legend
Shipped as a set which includes the Pushbutton, Lamp (lighted type only), and Switch.
For information on combinations, refer to Ordering Information on below.
Ordering Information
Completely Assembled
Shipped as a set which includes the Pushbutton, LED (lighted type only), and Switch.
Non-lighted (Round Type)
Operation |
Momentary operation |
Alternate operation |
Illumination |
|
Appearance |
Output |
Set |
Set |
|
Round/Half-guard type |
SPST-NO |
A22-H[]-10M |
A22-H[]-10A |
R (red) |
SPST-NC |
A22-H[]-01M |
A22-H[]-01A |
||
SPST-NO + SPST-NC |
A22-H[]-11M |
A22-H[]-11A |
||
SPST-NO + SPST-NO |
A22-H[]-20M |
A22-H[]-20A |
||
SPST-NC + SPST-NC |
A22-H[]-02M |
A22-H[]-02A |
||
Round/Small-size |
SPST-NO |
A22-S[]-10M |
--- |
|
SPST-NC |
A22-S[]-01M |
|||
SPST-NO + SPST-NC |
A22-S[]-11M |
|||
SPST-NO + SPST-NO |
A22-S[]-20M |
|||
SPST-NC + SPST-NC |
A22-S[]-02M |
Note: The contact ratings are for standard loads.
Non-lighted (Square Type)
Operation |
Momentary operation |
Alternate operation |
Illumination |
|
Appearance |
Output |
Set |
Set |
|
Square/Projection type |
SPST-NO |
A22-C[]-10M |
A22-C[]-10A |
R (red) |
SPST-NC |
A22-C[]-01M |
A22-C[]-01A |
||
SPST-NO + SPST-NC |
A22-C[]-11M |
A22-C[]-11A |
||
SPST-NO + SPST-NO |
A22-C[]-20M |
A22-C[]-20A |
||
SPST-NC + SPST-NC |
A22-C[]-02M |
A22-C[]-02A |
||
Square/Guard type |
SPST-NO |
A22-D[]-10M |
A22-D[]-10A |
|
SPST-NC |
A22-D[]-01M |
A22-D[]-01A |
||
SPST-NO + SPST-NC |
A22-D[]-11M |
A22-D[]-11A |
||
SPST-NO + SPST-NO |
A22-D[]-20M |
A22-D[]-20A |
||
SPST-NC + SPST-NC |
A22-D[]-02M |
A22-D[]-02A |
Note: The contact ratings are for standard loads.
Lighted (Round Type)
Operation |
Momentary |
Alternate |
Illumination |
|||
Appearance |
Output |
Lighting |
Operating |
Set |
Set |
|
Round/Half-guard |
SPST-NO |
LED |
24 VAC/ |
A22L-H[]-24A-10M |
A22L-H[]-24A-10A |
R (red) |
SPST-NC |
A22L-H[]-24A-01M |
A22L-H[]-24A-01A |
||||
SPST-NO + |
A22L-H[]-24A-11M |
A22L-H[]-24A-11A |
||||
SPST-NO + |
A22L-H[]-24A-20M |
A22L-H[]-24A-20A |
||||
SPST-NC + |
A22L-H[]-24A-02M |
A22L-H[]-24A-02A |
||||
Round/Half-guard |
SPST-NO |
100 VAC |
A22L-H[]-T1-10M |
A22L-H[]-T1-10A |
||
200 VAC |
A22L-H[]-T2-10M |
A22L-H[]-T2-10A |
||||
SPST-NC |
100 VAC |
A22L-H[]-T1-01M |
A22L-H[]-T1-01A |
|||
200 VAC |
A22L-H[]-T2-01M |
A22L-H[]-T2-01A |
||||
SPST-NO + |
100 VAC |
A22L-H[]-T1-11M |
A22L-H[]-T1-11A |
|||
200 VAC |
A22L-H[]-T2-11M |
A22L-H[]-T2-11A |
||||
SPST-NO + |
100 VAC |
A22L-H[]-T1-20M |
A22L-H[]-T1-20A |
|||
200 VAC |
A22L-H[]-T2-20M |
A22L-H[]-T2-20A |
||||
SPST-NC + |
100 VAC |
A22L-H[]-T1-02M |
A22L-H[]-T1-02A |
|||
200 VAC |
A22L-H[]-T2-02M |
A22L-H[]-T2-02A |
Note: The contact ratings are for standard loads.
Lighted (Square Type)
Operation |
Momentary |
Alternate |
Illumination |
|||
Appearance |
Output |
Lighting |
Operating |
Set |
Set |
|
Square/Projection |
SPST-NO |
LED |
24 VAC/ |
A22L-C[]-24A-10M |
A22L-C[]-24A-10A |
R (red) |
SPST-NC |
A22L-C[]-24A-01M |
A22L-C[]-24A-01A |
||||
SPST-NO + |
A22L-C[]-24A-11M |
A22L-C[]-24A-11A |
||||
SPST-NO + |
A22L-C[]-24A-20M |
A22L-C[]-24A-20A |
||||
SPST-NC + |
A22L-C[]-24A-02M |
A22L-C[]-24A-02A |
||||
Square/Projection |
SPST-NO |
100 VAC |
A22L-C[]-T1-10M |
A22L-C[]-T1-10A |
||
200 VAC |
A22L-C[]-T2-10M |
A22L-C[]-T2-10A |
||||
SPST-NC |
100 VAC |
A22L-C[]-T1-01M |
A22L-C[]-T1-01A |
|||
200 VAC |
A22L-C[]-T2-01M |
A22L-C[]-T2-01A |
||||
SPST-NO + |
100 VAC |
A22L-C[]-T1-11M |
A22L-C[]-T1-11A |
|||
200 VAC |
A22L-C[]-T2-11M |
A22L-C[]-T2-11A |
||||
SPST-NO + |
100 VAC |
A22L-C[]-T1-20M |
A22L-C[]-T1-20A |
|||
200 VAC |
A22L-C[]-T2-20M |
A22L-C[]-T2-20A |
||||
SPST-NC + |
100 VAC |
A22L-C[]-T1-02M |
A22L-C[]-T1-02A |
|||
200 VAC |
A22L-C[]-T2-02M |
A22L-C[]-T2-02A |
Note: The contact ratings are for standard loads.
Operation |
Momentary |
Alternate |
Illumination |
|||
Appearance |
Output |
Lighting |
Operating |
Set |
Set |
|
Square/Full-guard |
SPST-NO |
LED |
24 VAC/ |
A22L-D[]-24A-10M |
A22L-D[]-24A-10A |
R (red) |
SPST-NC |
A22L-D[]-24A-01M |
A22L-D[]-24A-01A |
||||
SPST-NO + |
A22L-D[]-24A-11M |
A22L-D[]-24A-11A |
||||
SPST-NO + |
A22L-D[]-24A-20M |
A22L-D[]-24A-20A |
||||
SPST-NC + |
A22L-D[]-24A-02M |
A22L-D[]-24A-02A |
||||
Square/Full-guard |
SPST-NO |
100 VAC |
A22L-D[]-T1-10M |
A22L-D[]-T1-10A |
||
200 VAC |
A22L-D[]-T2-10M |
A22L-D[]-T2-10A |
||||
SPST-NC |
100 VAC |
A22L-D[]-T1-01M |
A22L-D[]-T1-01A |
|||
200 VAC |
A22L-D[]-T2-01M |
A22L-D[]-T2-01A |
||||
SPST-NO + |
100 VAC |
A22L-D[]-T1-11M |
A22L-D[]-T1-11A |
|||
200 VAC |
A22L-D[]-T2-11M |
A22L-D[]-T2-11A |
||||
SPST-NO + |
100 VAC |
A22L-D[]-T1-20M |
A22L-D[]-T1-20A |
|||
200 VAC |
A22L-D[]-T2-20M |
A22L-D[]-T2-20A |
||||
SPST-NC + |
100 VAC |
A22L-D[]-T1-02M |
A22L-D[]-T1-02A |
|||
200 VAC |
A22L-D[]-T2-02M |
A22L-D[]-T2-02A |
Note: The contact ratings are for standard loads.
Subassembled
The Pushbutton, Lamp, or Switch can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for aintenance parts.
Pushbutton
Non-lighted
Sealing |
IP65 oil-resistant models |
|||
Appearance |
Half-guard type |
Round/Mushroom type |
Square/Projection type |
Square/Full-guard type |
Color |
Model |
Model |
Model |
Model |
Red |
A22-HR |
A22-SR |
A22-CR |
A22-DR |
Green |
A22-HG |
A22-SG |
A22-CG |
A22-DG |
Yellow |
A22-HY |
A22-SY |
A22-CY |
A22-DY |
White |
A22-HW |
A22-SW |
A22-CW |
A22-DW |
Blue |
A22-HA |
A22-SA |
A22-CA |
A22-DA |
Black |
A22-HB |
A22-SB |
A22-CB |
A22-DB |
Lighted
Sealing |
IP65 |
||
Appearance |
Half-guard type |
Square/Projection type
|
Square/Full-guard type
|
Color |
Model |
Model |
Model |
Red |
A22L-HR |
A22L-CR |
A22L-DR |
Green |
A22L-HG |
A22L-CG |
A22L-DG |
Yellow |
A22L-HY |
A22L-CY |
A22L-DY |
White |
A22L-HW |
A22L-CW |
A22L-DW |
Blue |
A22L-HA |
A22L-CA |
A22L-DA |
Lamp
LED Lamp
Operating voltage |
6 VAC/VDC |
12 VAC/VDC |
24 VAC/VDC |
||
Appearance |
LED light |
Model |
Model |
Model |
|
|
AC and DC |
Red |
A22-6AR |
A22-12AR |
A22-24AR |
Green |
A22-6AG |
A22-12AG |
A22-24AG |
||
Yellow *2 |
A22-6AY |
A22-12AY |
A22-24AY |
||
Blue |
A22-6AA |
A22-12AA |
A22-24AA |
*1. For voltage-reduction lighting, use the A22-24A[]. Only 24-V LED lamps can be used.
*2. Used when the Pushbutton color is yellow or white.
Switch (Standard Load)
No Voltage Reduction Unit
Classification |
Non-lighted
|
Lighted
|
|||
Operation |
Momentary |
Alternate |
Momentary |
Alternate |
|
Contacts |
Model |
Model |
Model |
Model |
|
Standard |
SPST-NO |
A22-10M |
A22-10A |
A22L-10M |
A22L-10A |
SPST-NC |
A22-01M |
A22-01A |
A22L-01M |
A22L-01A |
|
SPST-NO + SPST-NC |
A22-11M |
A22-11A |
A22L-11M |
A22L-11A |
|
SPST-NO + SPST-NO |
A22-20M |
A22-20A |
A22L-20M |
A22L-20A |
|
SPST-NC + SPST-NC |
A22-02M |
A22-02A |
A22L-02M |
A22L-02A |
Voltage Reduction Unit
Classification |
110 VAC, Lighted
|
220 VAC, Lighted
|
|||
Operation |
Momentary |
Alternate |
Momentary |
Alternate |
|
Contacts |
Model |
Model |
Model |
Model |
|
Standard |
SPST-NO |
A22L-10M-T1 |
A22L-10A-T1 |
A22L-10M-T2 |
A22L-10A-T2 |
SPST-NC |
A22L-01M-T1 |
A22L-01A-T1 |
A22L-01M-T2 |
A22L-01A-T2 |
|
SPST-NO + SPST-NC |
A22L-11M-T1 |
A22L-11A-T1 |
A22L-11M-T2 |
A22L-11A-T2 |
|
SPST-NO + SPST-NO |
A22L-20M-T1 |
A22L-20A-T1 |
A22L-20M-T2 |
A22L-20A-T2 |
|
SPST-NC + SPST-NC |
A22L-02M-T1 |
A22L-02A-T1 |
A22L-02M-T2 |
A22L-02A-T2 |
*1. A DPST-NO model is shown here as an example.
*2. For a model with a Voltage Reduction Unit, use the A22-24A[]. Only 24-V LED lamps can be used.
Accessories (Order Separately)
Accessories
Item |
Appearance |
Classification |
Model |
Remarks |
|||
Switch Blocks |
|
SPST-NO |
Standard |
A22-10 |
Order Switch Blocks to add an |
||
Microload |
A22-10S |
||||||
SPST-NC |
Standard |
A22-01 |
|||||
Microload |
A22-01S |
||||||
|
DPST-NO |
Standard |
A22-20 |
||||
Microload |
A22-20S |
||||||
DPST-NC |
Standard |
A22-02 |
|||||
Microload |
A22-02S |
||||||
SPST-NO + |
Standard |
A22-11 |
|||||
Microload |
A22-11S |
||||||
Lamp Sockets |
|
Direct lighting |
A22-TN |
||||
Voltage- |
110 VAC |
A22-T1 |
Used when changing the lighting |
||||
220 VAC |
A22-T2 |
||||||
Mounting Latches |
|
For momentary models |
A22-3200 |
Provided as standard. Order |
|||
For alternate models |
A22-3210 |
||||||
Legend |
Standard |
|
With Snap- |
White |
A22Z-3321 |
Snap-in Legend Plate is acrylic. |
|
Red |
A22Z-3322 |
||||||
Black |
A22Z-3323 |
||||||
Without Snap-in Legend |
A22Z-3320 |
||||||
Large |
|
With Snap- |
White |
A22Z-3331 |
Snap-in Legend Plate is acrylic. |
||
Red |
A22Z-3332 |
||||||
Black |
A22Z-3333 |
||||||
Without Snap-in Legend |
A22Z-3330 |
||||||
Lock Ring |
|
Round |
A22Z-3360 |
This Lock Ring is used when a |
|||
Metallic Bezel |
|
For flat or projection |
A22Z-3580 |
Replace with the standard model. |
|||
For full-guard models |
A22Z-3582 |
||||||
Sealing Caps |
|
For flat models |
A22Z-3600F |
Used to prevent dust or water |
|||
For projection models |
A22Z-3600T |
||||||
For full-guard models |
A22Z-3600G |
||||||
Color Caps |
|
Red |
A22Z-30TR |
Used for changing the |
|||
Green |
A22Z-30TG |
||||||
Yellow |
A22Z-30TY |
||||||
White |
A22Z-30TW |
||||||
Blue |
A22Z-30TA |
||||||
Caps |
For A22 |
|
For projection, full-guard, |
A22Z-3490 |
Material: polycarbonate resin |
||
For M22 |
For round models |
A22Z-3495 |
|||||
Three-throw |
|
--- |
A22Z-3003 |
Used when mounting three |
|||
Hole Plug |
|
Round |
A22Z-3530 |
Can be plugged into pre-cut |
|||
Control Boxes |
|
One hole |
A22Z-B101 |
For those designed A22Z-B1[], |
|||
A22Z-B201 |
|||||||
One hole, yellow box |
A22Z-B101Y |
||||||
A22Z-B201Y |
|||||||
Two holes |
A22Z-B102 |
||||||
A22Z-B202 |
|||||||
Three holes |
A22Z-B103 |
||||||
A22Z-B203 |
|||||||
Connectors |
|
Applicable |
7 to 9 dia. |
A22Z-3500-1 |
Plastic connector used to extend |
||
9 to 11 dia. |
A22Z-3500-2 |
||||||
25-dia. Ring |
|
--- |
A22Z-R25 |
Use when mounting to a panel |
|||
30-dia. Resin |
|
Round |
A22Z-A30 |
Use when mounting to a panel |
|||
Lock Plate |
|
--- |
A22Z-3380 |
Use to fix the lever on the |
|||
Simple |
|
--- |
A22Z-3700 |
Prevents foreign matter entering |
|||
Item |
Appearance |
Classification |
Model |
Remarks |
|||
Snap- |
Standard |
|
Without |
Black |
A22Z-3443B |
Attached to the |
|
Red |
A22Z-3443R |
||||||
White |
A22Z-3443W |
||||||
Transparent |
A22Z-3443C |
||||||
With text |
White text |
○ |
A22Z-3443R-2 |
||||
STOP |
A22Z-3443R-4 |
||||||
White text |
| |
A22Z-3443B-1 |
|||||
START |
A22Z-3443B-3 |
||||||
ON |
A22Z-3443B-5 |
||||||
OFF |
A22Z-3443B-6 |
||||||
UP |
A22Z-3443B-7 |
||||||
DOWN |
A22Z-3443B-8 |
||||||
POWER ON |
A22Z-3443B-9 |
||||||
OFF-ON |
A22Z-3443B-10 |
||||||
Large |
|
Without |
Black |
A22Z-3453B |
Used as an |
||
Red |
A22Z-3453R |
||||||
White |
A22Z-3453W |
||||||
Transparent |
A22Z-3453C |
||||||
For |
|
Black text |
60-dia. round plate with |
A22Z-3466-1 |
EMERGENCY STOP |
||
90-dia. round plate with |
A22Z-3476-1 |
||||||
Character Films |
|
No print (Round) |
A22Z-3460 |
After printing on a |
|||
Character |
| |
A22Z-3460-1 |
|||||
○ |
A22Z-3460-2 |
||||||
START |
A22Z-3460-3 |
||||||
STOP |
A22Z-3460-4 |
||||||
No print (Square) |
A22Z-3480 |
Tools
Item |
Appearance |
Classification |
Model |
Remarks |
Lamp Extractor |
|
--- |
A22Z-3901 |
Rubber tool used to easily replace Lamps |
Tightening Wrench |
|
--- |
A22Z-3905 |
Used to tighten mounting nuts from the back |
Cap Tightening Tool |
|
--- |
A22Z-3908 |
Used for replacing the cap of the Half-guard |
Cap Puller |
|
--- |
A3PJ-5080 |
Used for removing the cap from the Pushbutton |