Lighted Pushbutton Switches
A3P
Large Rectangular-bodied Lighted Pushbutton Switches
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load: 5 A at 125 VAC
3 A at 250 VAC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: 1. Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received certification, consult your supplier.
2. Only Switch output 1c and 2c are certified.
CCC (GB/T14048.5)
Standard Load: 3 A at 250 VAC
4 A at 30 VDC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Only Switch output 1c and 2c are certified.
Ratings
Contact Ratings
Silver Alloy Contacts (for Standard Loads)
Rated voltage (V) |
Non-inductive load (A) |
Inductive load (A) |
||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
|||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
|
125 VAC |
5 |
0.7 |
3 |
1.3 |
||||
8 VDC |
5 |
2 |
4 |
3 |
||||
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4; time constant = 7 ms.
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
Standard testing condition
(1) Ambient temperature: 20 ± 2°C
(2) Ambient humidity: 65 ± 5%RH
(3) Operating frequency: 20 times/min.
Gold Alloy Contacts (for Microloads)
Rated voltage (V) |
0.1 A at 30 VDC (resistive load); |
Minimum applicable load |
1 mA at 5 VDC |
LED Ratings
LED for LED-lighted Models
Single screen
Model |
A3PJ/M2PJ |
A3PA/M2PA |
|||||
Current |
Current |
||||||
Applied voltage |
Rated voltage |
Red, white |
Orange |
Green |
Red, white |
Orange |
Green |
5 VDC±5% |
5 VDC |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
12 VAC/VDC±5% |
12 VAC/VDC |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
24 VAC/VDC±5% |
24 VAC/VDC |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
LED for Chameleon Models
Applied voltage |
Rated voltage |
Current |
|
Green |
Red |
||
12 VDC±5% |
12 VDC |
Approx.26 mA |
Approx.20 mA |
24 VDC±5% |
24 VDC |
Approx.13 mA |
Approx.10 mA |
LED Lamp (for LED Lamp-lighted Models)
Type |
Applied voltage |
Rated voltage |
Current |
Model |
DC only |
5 VDC ± 5% |
5 VDC |
Approx. 30 mA |
SLL-05E[] |
12 VDC ± 5% |
12 VDC |
Approx. 15 mA |
SLL-12E[] |
|
24 VDC ± 5% |
24 VDC |
Approx. 12.5 mA |
SLL-24E[] |
• Mis-lighting of the LED
The LED lights with approx. 0.1 mA or less of micro-current. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED.
The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current.
Characteristics
Operating frequency |
Mechanical |
120 operations/minute max. *1 |
Electrical |
30 operations/minute max. |
|
Insulation resistance |
100 MΩ min. (at 500 VDC) |
|
Contact |
Standard load |
40 mΩ max. (initial value) |
Microload |
40 mΩ max. (initial value) |
|
Dielectric strength |
Between terminals of |
1,000 VAC, 50/60 Hz for 1 minute *2 |
Between terminals of |
2,000 VAC, 50/60 Hz for 1 minute |
|
Between current-carrying |
2,000 VAC, 50/60 Hz for 1 minute |
|
Between each terminal |
2,000 VAC, 50/60 Hz for 1 minute |
|
Between lamp terminals |
1,000 VAC, 50/60 Hz for 1 minute *3 |
|
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5 mm double amplitude (1 ms max.) |
Shock resistance |
Destruction |
500 m/s2 max. |
Malfunction |
200 m/s2 max. (1 ms max.) |
|
Life expectancy |
Mechanical |
Momentary operation models: 1,000,000 operations min. |
Electrical |
100,000 operations min. |
|
Weight |
Approx. 30 g |
|
Inrush current |
NC |
Silver contact: 10 A max. |
NO |
Silver contact: 10 A max. |
|
Ambient operating temperature |
LED-lighted models: -10°C to 40°C |
|
Ambient operating humidity |
35% to 85%RH |
|
Ambient storage temperature |
-25°C to 65°C |
|
Degree of protection |
IP40 |
|
Electric shock protection class |
Class II |
|
PTI (proof tracking index) |
175 |
|
Pollution degree |
3 (IEC947-5-1) |
*1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations.
*2. 600 VAC for microloads.
*3. With no LED lamp mounted.
Operating Characteristics
Model |
A3PJ series |
A3PA series |
A3PT series |
||||
Operating Characteristics |
Momentary operation models |
Alternate operation models |
Momentary operation models |
Alternate operation models |
Momentary operation models |
Alternate operation models |
|
Operating force |
OF max. |
5.88 N |
6.86 N |
5.88 N |
6.86 N |
3.92 N |
4.90 N |
Releasing force |
RF min. |
0.39 N |
0.29 N |
0.39 N |
0.29 N |
0.39 N |
0.29 N |
Total travel |
TT |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
Approx. |
Pretravel |
PT max. |
3 mm |
3 mm |
3 mm |
3 mm |
3 mm |
3 mm |
Lock travel alternate |
LTA min. |
--- |
0.5 mm |
--- |
0.5 mm |
--- |
0.5 mm |