Product Category

A3P

Lighted Pushbutton Switches

A3P

Large Rectangular-bodied Lighted Pushbutton Switches

Approved Standard Ratings

UL (File No. E41515), CSA (File No. LR45258)

Standard Load: 5 A at 125 VAC
                          3 A at 250 VAC
 Microload: 0.1 A at 125 VAC
                   0.1 A at 30 VDC
 Note: 1. Certification has been obtained for the Switch Unit.
              For detailed information on individual products that have received certification, consult your supplier.
          2. Only Switch output 1c and 2c are certified.

CCC (GB/T14048.5)

Standard Load: 3 A at 250 VAC
                          4 A at 30 VDC
 Microload: 0.1 A at 125 VAC
                   0.1 A at 30 VDC
 Note: Only Switch output 1c and 2c are certified.

Ratings

Contact Ratings

Silver Alloy Contacts (for Standard Loads)

Rated voltage (V)

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC
 250 VAC

5
 3

0.7
 0.5

3
 2

1.3
 0.8

8 VDC
 14 VDC
 30 VDC
 125 VDC
 250 VDC

5
 5
 4
 0.4
 0.2

2
 2
 2
 0.05
 0.03

4
 4
 3
 0.4
 0.2

3
 3
 3
 0.05
 0.03










Note: 1. The above values are for steady-state currents.
          2. Inductive load: Power factor = 0.4; time constant = 7 ms.
          3. The lamp load has an inrush current of 10 times the steady-state current.
          4. The motor load has an inrush current of 6 times the steady-state current.
 Standard testing condition
 (1) Ambient temperature: 20 ± 2°C
 (2) Ambient humidity: 65 ± 5%RH
 (3) Operating frequency: 20 times/min.

Gold Alloy Contacts (for Microloads) 

Rated voltage (V)

0.1 A at 30 VDC (resistive load);
 0.1 A at 125 VAC (resistive load)

Minimum applicable load

1 mA at 5 VDC

LED Ratings

LED for LED-lighted Models

Single screen

Model

A3PJ/M2PJ

A3PA/M2PA

Current

Current

Applied voltage

Rated voltage

Red, white

Orange

Green

Red, white

Orange

Green

5 VDC±5%

5 VDC

Approx.
 40 mA

Approx.
 20 mA

Approx.
 18 mA

Approx.
 20 mA

Approx.
 10 mA

Approx.
 9 mA

12 VAC/VDC±5%

12 VAC/VDC

Approx.
 20 mA

Approx.
 10 mA

Approx.
 8 mA

Approx.
 10 mA

Approx.
 5 mA

Approx.
 4 mA

24 VAC/VDC±5%

24 VAC/VDC

Approx.
 10 mA

Approx.
 5 mA

Approx.
 4 mA

Approx.
 10 mA

Approx.
 5 mA

Approx.
 4 mA

LED for Chameleon Models

Applied voltage

Rated voltage

Current

Green

Red

12 VDC±5%

12 VDC

Approx.26 mA

Approx.20 mA

24 VDC±5%

24 VDC

Approx.13 mA

Approx.10 mA

LED Lamp (for LED Lamp-lighted Models)

Type

Applied voltage

Rated voltage

Current

Model

DC only

5 VDC ± 5%

5 VDC

Approx. 30 mA

SLL-05E[]

12 VDC ± 5%

12 VDC

Approx. 15 mA

SLL-12E[]

24 VDC ± 5%

24 VDC

Approx. 12.5 mA

SLL-24E[]

• Mis-lighting of the LED
 The LED lights with approx. 0.1 mA or less of micro-current. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED.
 The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current. 

 image

Characteristics

Operating frequency

Mechanical

120 operations/minute max. *1

Electrical

30 operations/minute max.

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact
 resistance

Standard load

40 mΩ max. (initial value)

Microload

40 mΩ max. (initial value)

Dielectric strength

Between terminals of
 same polarity

1,000 VAC, 50/60 Hz for 1 minute *2

Between terminals of
 different polarity

2,000 VAC, 50/60 Hz for 1 minute

Between current-carrying
 metal part and ground

2,000 VAC, 50/60 Hz for 1 minute

Between each terminal
 and non-current-carrying
 metal part

2,000 VAC, 50/60 Hz for 1 minute

Between lamp terminals

1,000 VAC, 50/60 Hz for 1 minute *3

Vibration resistance

Malfunction

10 to 55 Hz, 1.5 mm double amplitude (1 ms max.)

Shock resistance

Destruction

500 m/s2 max.

Malfunction

200 m/s2 max. (1 ms max.)

Life expectancy

Mechanical

Momentary operation models: 1,000,000 operations min.
 Alternate operation models: 200,000 operations min.
 (One operation consists of set and reset operations.)

Electrical

100,000 operations min.

Weight

Approx. 30 g

Inrush current

NC

Silver contact: 10 A max.

NO

Silver contact: 10 A max.

Ambient operating temperature

LED-lighted models: -10°C to 40°C
 (with no icing or condensation)

Ambient operating humidity

35% to 85%RH

Ambient storage temperature

-25°C to 65°C

Degree of protection

IP40

Electric shock protection class

Class II

PTI (proof tracking index)

175

Pollution degree

3 (IEC947-5-1)

*1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations.
 *2. 600 VAC for microloads.
 *3. With no LED lamp mounted. 

Operating Characteristics

Model

A3PJ series

A3PA series

A3PT series

Operating Characteristics

Momentary operation models

Alternate operation models

Momentary operation models

Alternate operation models

Momentary operation models

Alternate operation models

Operating force

OF max.

5.88 N

6.86 N

5.88 N

6.86 N

3.92 N

4.90 N

Releasing force

RF min.

0.39 N

0.29 N

0.39 N

0.29 N

0.39 N

0.29 N

Total travel

TT

Approx.
 3.5 mm

Approx.
 3.5 mm

Approx.
 3.5 mm

Approx.
 3.5 mm

Approx.
 3.5 mm

Approx.
 3.5 mm

Pretravel

PT max.

3 mm

3 mm

3 mm

3 mm

3 mm

3 mm

Lock travel alternate

LTA min.

---

0.5 mm

---

0.5 mm

---

0.5 mm