Rotary paddle level switch
Rotonivo® - RN 3004
						
											
						
											Application area
The rotating paddle detector Rotonivo® RN 3004 is used in storage and process vessels as a full, demand and empty detector in all bulk materials. It can be configured for process temperatures up to +600°C and process overpressure up to 10 bar and is mechanically very resilient. Buildup or a dust-intensive process environment does not in any way affect the accuracy of the measurement results of the level indicator.
Technical Data
| Measurement principle | Rotary Paddle | 
|---|---|
| Measuring task | Point level measurement | 
| Version | Pipe extension horizontal | 
| Medium | Solids | 
| Mounting position | 
  | 
| Ambient temperature | -40°C … +60°C (-40°F … +140°F) | 
| Process temperature | -40°C … +600°C (-40°F … +1112°F) | 
| Process pressure | -0,9 bar … +10 bar (-13.1 psi … +145 psi) | 
| Minimum sensitivity | > 15 g/l (> 0.9 lbs/ft3) | 
| Housing type | standard | 
| Housing material | 
  | 
| Housing protection rating | IP66 | 
| Threaded connection | 
  | 
| Flange connection | 
  | 
| Hygienic fittings | ≥ Triclamp 2″ | 
| Wetted materials | 
  | 
| Mechanical load | 
  | 
| Accuracy | — | 
| Min. immersion length | 125 mm (4.92″) | 
| Max. immersion length | 600 mm (2′) | 
| Power supply | 
  | 
| Signal output | 
  | 
| Approvals | 
  | 
| Explosion protection | Dust Ignitionproof (Ex t) | 
| Hygienic / Pharma | 
  | 
| Ship approval | — | 
| Overfill protection | — | 
| SIL qualification | — | 
| Further approvals | — | 
| User Interface | 
  | 
| Optical indicator | LED | 
| Adjustment possibility | 
  |