Radar sensors

NivoGuide® – NG 8100

Application area

The guided radar sensor NivoGuide® 8100 measures the level of liquids or oils of any kind. In addition to level measurement, this TDR sensor can also reliably and precisely detect an interface, which is likely to be formed between two liquids. Due to the robust sensor design and a wide range of versions, the sensors are suitable to be used in large storage tanks as well as in small process vessels or bypass tubes. 

Technical Data

Measurement principleGuided Radar (TDR)
Measuring task
  • Continuous level measurement
  • Interface level measurement
Version
  • Rod version
  • Rope version
  • Coaxial version
MediumLiquids
Mounting position
  • top
  • in a Bypass
  • in a Standpipe
  • on a Socket
Ambient temperature-40°C … +80°C (-40°F … +176°F)
Process temperature-40°C … +200°C (-40°F … +392°F)
Process pressure-1 bar … +40 bar (-14.5 psi … +580 psi)
Minimum sensitivityDK ≥ 1.4
Housing type
  • flameproof
  • flameproof double chamber
Housing material
  • Aluminium
  • Stainless steel 1.4404 (316L)
Housing protection ratingIP68, Type 6P
Threaded connection
  • ≥ G 3/4″
  • ≥ NPT 3/4″
  • ≥ M30 x 1,5
Flange connection
  • ≥ DN25
  • ≥ 1″
Hygienic fittingsTriclamp adapter
Wetted materials
  • Stainless steel 1.4404 (316L)
  • Stainless steel 1.4401 (316)
  • FKM
  • FFKM
  • EPDM
  • FEP
  • PPS
  • PEEK
Mechanical load
  • rod (Ø 8 mm): 10 Nm
  • rod (Ø 12 mm): 30 Nm
  • rope (Ø 2 mm): 1,5 kN
  • rope (Ø 4 mm): 2,5 kN
  • coax (Ø 21,3 mm): 60 Nm
  • coax (Ø 42,2 mm): 300 Nm
Accuracy± 2 mm (± 0.07″)
Min. immersion length
  • rod: 300 mm (11.8″)
  • coax: 300 mm (11.8″)
  • rope: 500 mm (19.7″)
Max. immersion length
  • coax: 6 m (19.82′)
  • rod: 6 m (19.82′)
  • rope: 75 m (246′)
Power supply9,6…35V DC
Signal output4…20 mA/ HART (2-wire)
Approvals
  • CE
  • General purpose
  • ATEX
  • IEC-Ex
  • INMETRO
  • TR-CU
  • FM
Explosion protection
  • Dust Ignitionproof (Ex t)
  • Intrinsic Safe (Ex i)
  • Explosionproof/ Flameproof (Ex d)
  • Non-incendive
Hygienic / Pharma
  • EG 1935/2004
  • FDA
Ship approval
Overfill protection
SIL qualificationSIL 2/3
Further approvals
User Interface
  • LCD Display with push buttons
  • PACTware (DTM)
  • HART Modem
Optical indicatorDisplay
Adjustment possibility
  • self diagnostics
  • menu-driven quick start
  • echo analysis
  • volume table