Process assembly Unifit CPA442

Hygienic assembly for the life sciences, food & beverage industries

Predecessor: CPA440, CPA441

Successor: Unifit CPA842

  • Process temperature: max. 140°C
  • Process pressure: max. 10bar

 

Manual retractable assembly Cleanfit CPA450

Basic assembly for the water & wastewater, chemical, pulp & paper and power industries

Predecessor: CPA461

  • Process temperature: -15 to 130 °C (5 to 266 °F)
  • Process pressure: Max. 12 bar at 100 °C (175 psi at 212 °F)

 

Manual or automatic retractable assembly Cleanfit CPA472D

Heavy-duty assembly for chemical and power industries

  • Process temperature: 0 to 140 °C (32 to 284 °F)
  • Process pressure: 0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation, 0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

 

Manual or automatic retractable assembly Cleanfit CPA473

Assembly with ball valve for the chemical, paper, and wastewater industries

Predecessor: Cleanfit P CPA477, CPA463

  • Process temperature: PA pressure cylinder (manually only):, Max. 80 °C (176 °F), Stainless steel pressure cylinder: up to 100°C (212 °F) with continuous operation up to 6 bar (87 psi)
  • Process pressure: PA pressure cylinder: Max. 6 bar (87 psi), Stainless steel pressure cylinder: Max. 10 bar (145 psi), Pneumatic outlet safety seal:, 6 bar at 100 °C (87 psi at 212 °F)

 

Manual or automatic retractable assembly Cleanfit CPA474

Assembly with ball valve for chemical and industrial wastewater applications

Predecessor: CPA463

  • Process temperature: PA version: max. 80 °C (max. 176 °F), Stainless steel pressure cylinder: max. 120 °C (248 °F)
  • Process pressure: PA pressure cylinder: max. 6 bar (87 psi), Stainless steel pressure cylinder: max. 10 bar (145 psi) at 40 °C (104 °F)

 

Process assembly Ecofit CPA640

Universal assembly mainly for water and wastewater

Predecessor: CPA642

Process assembly Unifit CPA842

Hygienic assembly for the life sciences, food & beverage industries

Predecessor: Unifit H CPA442

  • Process temperature: -15 to 140 °C (5 to 280 °F)
  • Process pressure: 16 bar up to 140 °C (232 psi up to 284 °F)

 

Analog pH sensor Purisys CPF201

Compact electrode for power and life sciences industries

  • Measurement range: pH 1-13 (<100µS/cm)
  • Process temperature: 2°C – 75°C, (36°F – 167°F)
  • Process pressure: max. 3 bar, (43.5 psi)

 

Analog pH sensor Orbipac CPF81

Compact electrode for wastewater, primaries and metal

Predecessor: CPF91, CPF10

  • Measurement range: pH 0-14
  • Process temperature: -10°C – 110°C, (14°F – 230°F)
  • Process pressure: max. 10 bar, (145 psi)

 

Analog ORP sensor Orbipac CPF82

Compact electrode for wastewater, primaries and metal

Predecessor: Orbipore CPS92, CPF92

  • Measurement range: -1500mV – -1500mV
  • Process temperature: -10°C – 110°C, (14°F – 230°F)
  • Process pressure: max. 10 bar, (145 psi)

 

Digital pH sensor Memosens CPL53E

Versatile Memosens 2.0 pH glass sensor for laboratory measurement and random sampling

  • Measurement range: pH 0 to 14 (1 to 12 application range)
  • Process temperature: –5 to 100 °C (23 to 212 °F) (0 to 80 °C (32 to 176 °F) application range)
  • Process pressure: 1 bar, not intended for continues measurment in process

 

Digital pH sensor Memosens CPL57E

Memosens 2.0 pH sensor for laboratory measurement and random sampling in pure and ultrapure water

  • Measurement range: pH 0 to 14 (1 to 12 application range)
  • Process temperature: –5 to 100 °C (23 to 212 °F) (0 to 80 °C (32 to 176 °F) application range)
  • Process pressure: 1 bar, not intended for continues measurment in process

 

Digital pH sensor Memosens CPL59E

Rugged Memosens 2.0 pH sensor for laboratory measurements and random sampling in demanding media

  • Measurement range: pH 0 to 14
  • Process temperature: 0 to 135 °C (32 to 275 °F) (0 to 100 °C (32 to 212 °F) application range)
  • Process pressure: 1 bar, not intended for continues measurement in process

 

pH/ORP transmitter Liquisys CPM223

Compact panel device for all industries

Predecessor: CPM120, CPM121, CPM220, CPM221

  • Input: One-channel-transmitter
  • Output / communication: 0/4-20mA, Hart, Profibus.
  • Ingress protection: IP65

 

pH/ORP transmitter Liquisys CPM253

Compact field device for all industries

Predecessor: CPM141S, CPM240S, CPM140, CPM130, CPM141, CPM230, CPM240, CPM151, CPM252

  • Input: One-channel-transmitter
  • Output / communication: 0/4-20 mA, Hart, Profibus
  • Ingress protection: No

 

Analog pH sensor Orbisint CPS11

Glass electrode for standard applications

  • Measurement range: pH 0-14
  • Process temperature: max. 135°C (274°F)
  • Process pressure: max. 16 bar (230 psi)

Analog ORP sensor Orbisint CPS12

Glass electrode for standard applications

Predecessor: CPS22

  • Measurement range: -1500 mV to +1500 mV
  • Process temperature: max. 135°C (274°F)
  • Process pressure: max. 16bar (230psi)

 

Analog pH sensor Ceratex CPS31

Glass electrode for application in drinking water and swimming pools

  • Measurement range: pH 1 – 12
  • Process temperature: 0 – 80 C (32 – 176 F)
  • Process pressure: 1 – 4 bar abs (15 – 60 psi)

 

Analog pH sensor Ceraliquid CPS41

Glass electrode for applications with fast-changing medium compositions or low conductivity

  • Measurement range: pH 0-14
  • Process temperature: max. 135°C (274°F)
  • Process pressure: max. 10bar (145psi)

 

Digital pH sensor Memosens CPS41E

Memosens 2.0 pH electrode for demanding applications in the chemical and process industries

Predecessor: Ceraliquid CPS41D

  • Measurement range: Application A: • pH: 1 to 12, Application B: • pH: 0 to 14
  • Process temperature: Application A: –15 to 80 °C (5 to 176 °F), Application B: 0 to 135 °C (32 to 275 °F)
  • Process pressure: 0.8 to 11 bar (11.6 to 159.5 psi) absolu

Analog ORP sensor Ceraliquid CPS42

Glass electrode for applications with fast-changing medium compositions or low conductivity
Hide details

  • Measurement range: -1500 mV – +1500 mV
  • Process temperature: -15°C – 130°C
  • Process pressure: max. 8bar

 

Digital non-glass pH sensor Memosens CPS47E

Memosens 2.0 ISFET pH electrode for the chemical, life sciences and food industries

Predecessor: Tophit CPS441D, Tophit CPS441, Memosens CPS47D

  • Measurement range: pH 0 to 14
  • Process temperature: -15 to 135 °C (5 to 275 °F)
  • Process pressure: Max. 11 bar abs at 100 °C (max. 160 psi at 212 °F)

 

Analog pH sensor Ceragel CPS71

Glass electrode for food and life sciences industries

  • Measurement range: pH 0-14
  • Process temperature: -15°C … 140°, (5°F – 284°F)
  • Process pressure: max. 13 bar, (188 psi)

 

Analog ORP sensor Ceragel CPS72

Glass electrode for food and life sciences industries

Predecessor: CPS32

  • Measurement range: -1500 mV – +1500 mV
  • Process temperature: -15°C – 135°C
  • Process pressure: max. 16bar

 

Analog pH sensor Orbipore CPS91

Glass electrode for heavily polluted media in chemical processes, paper or paint production

  • Measurement range: pH 0-14
  • Process temperature: max. 110°C, (230°F)
  • Process pressure: max. 10 bar, (145 psi)

 

Digital pH sensor Memosens CPS91E

Memosens 2.0 pH electrode for heavily soiled media in chemical processes, paper or paint production

Predecessor: Orbipore CPS91D

  • Measurement range: 1 to 14 pH
  • Process temperature: 0 to 110 °C (32 to 230 °F)
  • Process pressure: 0.8 to 14 bar (11.6 to 203 psi) absolute

 

Digital ORP sensor Memosens CPS92E

Memosens 2.0 glass sensor for heavily polluted media in chemical industry, paper, pigment production

Predecessor: Orbipore CPS92, Orbitec CPS92D

  • Measurement range: –1 500 to 1 500 mV
  • Process temperature: 0 to 110 °C (32 to 230 °F)
  • Process pressure: 0.8 to 14 bar (11.6 to 203 psi) (absolute)

 

pH buffers CPY20

Highly precise pH buffers for all industries

Predecessor: CPY1, Buffer CPY2, CPY1

Sampling assembly Samplefit CSA420

Assembly for taking samples in process applications

  • Process temperature: 0 – 50°C
  • Process pressure: up to 6 bar

 

Automatic water sampler Liquistation CSF28

Target-oriented and easy automatic sampling in water and wastewater applications

Predecessor: ASP Station 2000 RPS20B, CSF33

  • Functions: Stationary sampler
  • Suction height: 6 m (19.69 ft) suction height, 8 m (26.25 ft) suction height
  • Cabinet: Plastic ASA+PC
  • Process temperature: Sample temperature: 2 to 50 °C, (36 to 122 °F)
  • Process pressure: Max. 0.8 bar, (Max. 11.6 psi)