Liquid Analysis
Endress+Hauser Liquid Analysis is one of the world’s leading providers of measuring instruments and complete systems for liquid analysis.
Products List
![](https://tecteslabd.com/wp-content/uploads/2023/11/CM44_pH-1-300x300.jpg)
4-channel transmitter Liquiline CM444
Expandable multiparameter field device for all industries
Predecessor: CCM360, Sludge level CUM750
Input:1 to 4x Memosens digital input, 2x 0/4 to 20mA Input optional, 2 to 4x Digital input optional
Output / communication: 2 to 8x 0/4 to 20 mA current outputs, alarmrelay, 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Ingress protection: IP66 / IP 67
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS11E-pH-sensor-Memosens-straight-300x300.jpg)
Digital pH sensor Memosens CPS11E
Memosens 2.0 pH electrode for standard applications in process and water & wastewater industries
Predecessor: Orbisint CPS11D
Measurement range: Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
Application F
• pH: 0 to 10Process temperature: Application A: –15 to 80 °C (5 to 176 °F), Application B: 0 to 135 °C (32 to 275 °F), Application F: 0 to 70 °C (32 to 158 °F)
Process pressure: Applications A and B: 0.8 to 17 bar (11.6 to 246.5 psi) absolute, Application F:0.8 to 7 bar (11.6 to 101.5 psi) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CA80_closed-300x300.jpg)
Ammonium analyzer Liquiline System CA80AM
Colorimetric system for online monitoring of water and wastewater treatment
Predecessor: Stamolys CA71AM
Measurement range: 0.05 to 20 mg/l NH4-N
0.5 to 50 mg/l NH4-N
1 to 100 mg/l NH4-N
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l NH4-NProcess temperature: 4 to 40 °C (39 to 104 °F)
Process pressure: Unpressurized
Measuring method: Comply with standard colorimetric measuring principle – indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87
![](https://tecteslabd.com/wp-content/uploads/2023/11/CA80COD_analyzer_closed-300x300.jpg)
COD analyzer Liquiline System CA80COD
Analyzer for chemical oxygen demand in environmental monitoring, industrial and municipal wastewater
Predecessor: Stamolys CA71COD
Measurement range; 0 to 500 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method + dilution module (1:4)Process temperature: 4 to 40 °C (39 to 104 °F)
Process pressure: Atmospheric
![](https://tecteslabd.com/wp-content/uploads/2023/11/CA80_PH_closed-300x300.jpg)
Orthophosphate analyzer Liquiline System CA80PH
Colorimetric system for wastewater monitoring and optimization of process control
Predecessor: Stamolys CA71PH
Measurement range: 0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)Process temperature: 4 to 40 °C (39.2 to 104 °F)
Process pressure: At atmospheric pressure, < 0.2 bar
![](https://tecteslabd.com/wp-content/uploads/2023/11/chlorine_dioxide_sensor_CCS50D_g-300x300.jpg)
Digital chlorine dioxide sensor Memosens CCS50D
Memosens sensor for water, process water and utilities in all industries
Measurement range: Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2Process temperature: 0 to 55 °C , non-freezing(32 to 130 °F)
Process pressure: Max. 2 bar abs (Max. 29 psi abs)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CCS51D_free_chlorine_sensor-300x300.jpg)
Digital free chlorine sensor Memosens CCS51D
Memosens sensor for drinking water, pool and process water as well as utilities in all industries
Predecessor: Chloromax CCS142D
Measurement range: Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOClProcess temperature: 0 to 55 °C (32 to 130 °F), non-freezing
Process pressure: Max. 1 bar (max. 14.5 psi)
Measuring method: Closed, membrane covered measuring cell. Reduction of free chlorine at the cathode
![](https://tecteslabd.com/wp-content/uploads/2023/11/CDC90_front-300x300.jpg)
Cleaning and calibration system Liquiline Control CDC90
Fully automatic system for pH and ORP measuring points in all industries
Predecessor: Topcal S CPC310
![](https://tecteslabd.com/wp-content/uploads/2023/11/CFS51_front-300x300.jpg)
PAH sensor Memosens CFS51
Memosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)
Measurement range: 0.000 to 5000 PAHphe
Process temperature: -5 to 55 °C (20 to 130 °F)
Process pressure: 10 bar abs. (just the sensor), 6 bar abs. (combination sensor and assembly)
![](https://tecteslabd.com/wp-content/uploads/2023/11/Spectrometer-Memosens-Wave-CKI50_009-300x300.jpg)
Process spectrometer Memosens Wave CKI50
Memosens Wave spectrometer for color measurement in the Food & Beverage, Chemical and Life Sciences industries
Measurement range: L: 0 to 100
a: -150 to 100
b: -100 to 150Process temperature: -20 to 60 °C (-4 to 140 °F)
60 to 140 °C (140 to 284 °F) with water coolingProcess pressure: 0.5 to 10 bar (7.3 to 145 psi) (absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLS82D_angular-300x300.jpg)
Digital 4-electrode conductivity sensor Memosens CLS82D
Memosens conductive conductivity sensor for hygienic applications in Life Sciences, Pharma and Food
Predecessor: Condumax CLS30
Successor: Memosens CLS82E
- Measurement range: 1 µS/cm to 500 mS/cm
- Process temperature: -5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min (Max. 284 °F at 87 psi for max. 45 min)
Process pressure: 17 bar abs at 20 °C (247 psi at 68 °F), 9 bar abs at 120 °C (131 psi at 248 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/COS81D_front-300x300.jpg)
Digital oxygen sensor Memosens COS81D
Memosens optical oxygen sensor for hygienic applications in Life Sciences, Pharma and Food
Successor: Memosens COS81E
- Measurement range:0.004 to 30 mg/l
0.05 to 330 %SAT
0.1 to 700 hPa
- Process temperature: 0 to 140 °C (32 to 284 °F)
- Process pressure: 0.02 to 13 bar abs (0 to 190 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPF81E-digital-pH-sensor-300x300.jpg)
Digital pH sensor Memosens CPF81E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Predecessor: Orbipac CPF81D
Measurement range: pH 0 to 14
Process temperature: Version LH: 0 to 110 °C (32 to 230 °F), Version NN: 0 to 80 °C (32 to 170 °F)
Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi at 176 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPF82E-digital-ORP-sensor-300x300.jpg)
Digital ORP sensor Memosens CPF82E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Predecessor: Orbipac CPF82D
Measurement range: -1500mV to +1500mV
Process temperature: 0 to 80 °C (32 to 170 °F)
Process pressure: 1 to 10 bar abs at 80 °C (15 to 145 psi abs at 176 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS171D_front-300x300.jpg)
Digital pH sensor Memosens CPS171D
Memosens glass electrode for bioreactors in the biotech industry and for the food industry
Successor: Memosens CPS61E
Measurement range: pH 0 to 14
Process temperature: 0 to 135 °C (32 to 275 °F)
Process pressure: 1 to 7 bar abs (14.5 to 101.5 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS61E-digital-ph-sensor-300x300.jpg)
Digital pH sensor Memosens CPS61E
Memosens 2.0 glass sensor for the food & beverage industry and for bioreactors in biotech industry
Predecessor: Ceragel CPS71D, Memosens CPS171D
Measurement range: pH: 0 to 14
Process temperature: Application N: 0 to 100 °C (32 to 212 °F) Up to 140 °C (284 °F) for sterilization
Process pressure: 0.8 to 7 bar (11.6 to 101.5 psi) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS62E-ORP-sensor-nonEx-300x300.jpg)
Digital ORP sensor Memosens CPS62E
Memosens 2.0 ORP electrode for the chemical and life sciences industries
Measurement range: –1 500 to 1 500 mV
Process temperature: 0 to 100 °C (32 to 212 °F) 0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)
Process pressure: 0.8 to 7 bar (11.6 to 101.5 psi) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS71E-pH-sensor-300x300.jpg)
Combined pH/ORP sensor Memosens CPS76E
Memosens 2.0 pH electrode for chemical processes and poisoning media
Predecessor: Ceragel CPS71D
- Measurement range: ORP: –1 500 to 1 500 mV
Application B
• pH: 0 to 14
Application H
• pH: 0 to 12
Process temperature: Application B and H: 0 to 140 ° C (32 to 284 ° F)
Version TB: 0 to 140 ° C (32 to 284 ° F)
Version TU, TP (pressurized reference): 0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
maximum 100 ° C (212 ° F) in continuous operation due to increasing pressure drop at T> 100 ° C (212 ° F)Process pressure: Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS76E-combined-pH-ORP-sensor-300x300.jpg)
Digital pH sensor Memosens CPS71E
Memosens 2.0 combined electrode for chemical processes and poisoning media
Predecessor: Memosens CPS76D
Measurement range: Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12Process temperature: 1 to 140 °C (32 to 284 °F)
Process pressure: 0,8 to 14 bar (11,6 to 203 psi) (absolute)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CPS96E-combined-pH-ORP-sensor-300x300.jpg)
Digital combined pH/ORP sensor Memosens CPS96E
Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production
Predecessor: Memosens CPS96D
Measurement range: ORP: –1 500 to 1 500 mV
pH: 0 to 14Process temperature: 0 to 110 °C (32 to 230 °F)
Process pressure: 0.8 to 14 bar (11.6 to 203 psi) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CUS52D_03-300x300.jpg)
Turbidity sensor Turbimax CUS52D
Hygienic Memosens sensor for turbidity measurement in drinking water, process water and utilities
Predecessor: Turbimax CUE21, Turbimax CUS31, Turbimax CUS65
Measurement range: 0.000 to 4000 FNU
Process temperature: Stainless steel version: -20 to 85 °C (0 to 185 °F)
Plastic version: -20 to 60°C (-4 to 140 °F)Process pressure: Stainles steel version: 0.5 to 10 bar abs
(7.3 to 145 psi abs)
Plastic version: 0.5 to 6 bar abs
(7.3 to 87 psi abs)
![](https://tecteslabd.com/wp-content/uploads/2023/11/Liquitrend_QMW43_PP_01-300x300.jpg)
Liquid Analysis Physical Medium Properties Liquitrend QMW43
Compact device for continuous buildup thickness and conductivity measurement
Measurement range: Conductivity: 0 µS/ cm…100 mS/ cm
Build-up thickness: 0 mm…10 mmProcess temperature: -20°C…+100°C (-4°F…+212°F) +150°C (+302°F) for 1h
Process pressure: Vacuum…25 bar, (Vacuum…362.5 psi)
Measuring method: Capacitive- conductive
![](https://tecteslabd.com/wp-content/uploads/2023/11/CAS51D_front-300x300.jpg)
Digital nitrate or SAC sensor Viomax CAS51D
Memosens sensor for optical measurement of nitrate, SAC, CODeq, TOCeq, BODeq or DOCeq
Predecessor: Stamosens CSS70, Stamosens CNS70
Measurement range: 0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N
0.04 to 80 mg/l / 0.4 to 200 mg/l NO3
0 to 50 1/m / 0 to 250 1/m / 0 to 1000 1/m SAC
0 to 75 mg/l / 0 to 375 mg/l / 0 to 1500 mg/l COD/BOD (254nm)
0 to 30 mg/l / 0 to 150 mg/l / 0 to 600 mg/l TOC/DOC (254nm)Process temperature: 5 to 50°C (41 to 120 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CCS120D_total_chlorine_sensor_Memosens-300x300.jpg)
Digital total chlorine sensor Memosens CCS120D
Memosens disinfection sensor for wastewater and process water
Measurement range: 0.1 to 10 mg/l total chlorine
Process temperature: 5 to 45 °C (41 to 113 °F)
Process pressure: 1 to 4 bar (14.5 to 58 psi)
Measuring method: Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent
![](https://tecteslabd.com/wp-content/uploads/2023/11/CCS55D_free_bromine_sensor_straight-300x300.jpg)
Digital free bromine sensor Memosens CCS55D
Memosens sensor for seawater and process water
Measurement range: Trace: 0 … 5 mg/l HOBr
Standard: 0 … 20 mg/l HOBr
High: 0 … 200 mg/l HOBrProcess temperature: +0…55 °C (32 … 130°F), non-freezing
Process pressure: Max. 1 bar (max. 14.5 psi)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLD18-300x300.jpg)
Compact conductivity device Smartec CLD18
Toroidal conductivity measuring system for hygienic applications
Predecessor: CLD133, CLD633
Measurement range: 200 µS/cm to 1000 mS/cm, Cell constant k: 11.0 1/cm
Process temperature: -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min (Max. 266 °F at 87 psi up to 60 min)Process pressure: 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLS15E-conductivity-sensor-300x300.jpg)
Digital conductivity sensor Memosens CLS15E
Memosens 2.0 contacting conductivity sensor for standard applications in pure and ultrapure water
Predecessor: Condumax CLS15D
Measurement range: k=0,01: 0.04 to 20 µS/cm, k=0,1: 0.10 to 200 µS/cm
Process temperature: Threaded with fixed cable: -20 to 100 °C (-4 to 212 °F)
Threaded with plug-in head: -20 to 120 °C (-4 to 248 °F)
Sterilization: max. 140 °C (284 °F) for 30 minutesProcess pressure: 13 bar at 20 °C (188 psi at 68 °F) absolute
1 bar at 120 °C (14 psi at 248 °F) absolute
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLS16D_angular-300x300.jpg)
Digital conductivity sensor Condumax CLS16D
Memosens conductive conductivity sensor for hygienic applications in pure and ultrapure water
Successor: Memosens CLS16E
Measurement range: k=0,1: 0,04 to 500 µS/cm
Process temperature: -5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar (Max. 302 °F at 73 psi)Process pressure: 13 bar at 20 °C (188 psi at 68 °F), 9 bar at 120 °C (130 psi at 248 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLS16E-conductivity-sensor-300x300.jpg)
Digital conductivity sensor Memosens CLS16E
Memosens 2.0 contacting conductivity sensor for hygienic applications in life sciences and food
Predecessor: Condumax CLS16D
Measurement range: k=0,1: 0,04 to 500 µS/cm
Process temperature: -5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar (Max. 302 °F at 73 psi)Process pressure: 13 bar at 20 °C (188 psi at 68 °F), 9 bar at 120 °C (130 psi at 248 °F)
![](https://tecteslabd.com/wp-content/uploads/2023/11/CLS21E-conductivity-sensor-300x300.jpg)
Digital conductivity sensor Memosens CLS21E
Memosens 2.0 contacting conductivity sensor for surface and drinking water monitoring
Predecessor: Condumax CLS21D
Measurement range: k=1: 10 µS/cm to 20 mS/cm
Process temperature: -20 to 135 °C at 3.5 bar abs (-4 to 275 °F at 50 psi)
Process pressure: 17 bar abs at 20 °C (246 psi at 68 °F)