I/O Relay Terminal
G70V
Our Value Design Products Increase the Value of Your Control Panels. I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor.
Model Number Legend
Ordering Information
I/O Relay Terminal
Terminals | Classifi cation | Points | Common Line | Rated voltage | Model | |
Terminal Block Side | Connector Side | |||||
Push-In Plus terminal blocks | Input *1 | 16 | No internal connections | NPN (- common) | 24 VDC | G70V-SID16P |
PNP (+ common) | G70V-SID16P-1 | |||||
16 points internally connected | NPN (- common) | G70V-SID16P-C16 | ||||
PNP (+ common) | G70V-SID16P-1-C16 | |||||
Output *2 | No internal connections | NPN (+ common) | G70V-SOC16P | |||
PNP (- common) | G70V-SOC16P-1 | |||||
Every 4 points internally connected at terminal block bottom row | NPN (+ common) | G70V-SOC16P-C4 | ||||
PNP (- common) | G70V-SOC16P-1-C4 |
*1. Mountable Relays: G2RV-1-S-AP-G DC21V.
*2. Mountable Relays: G2RV-1-S-G DC21V.
*2. Mountable Relays: G2RV-1-S-G DC21V.
I/O Terminal Sockets
Applicable I/O Relay Terminal | Classification | Common Line | Model | |
Terminal Block Side | Connector Side | |||
G70V-SID16P | Input | No internal connections | NPN (- common) | G70V-ZID16P |
G70V-SID16P-1 | PNP (+ common) | G70V-ZID16P-1 | ||
G70V-SID16P-C16 | 16 points internally connected | NPN (- common) | G70V-ZID16P-C16 | |
G70V-SID16P-1-C16 | PNP (+ common) | G70V-ZID16P-1-C16 | ||
G70V-SOC16P | Output | No internal connections | NPN (+ common) | G70V-ZOM16P |
G70V-SOC16P-1 | PNP (- common) | G70V-ZOM16P-1 | ||
G70V-SOC16P-C4 | Every 4 points internally connected at terminal block bottom row | NPN (+ common) | G70V-ZOM16P-C4 | |
G70V-SOC16P-1-C4 | PNP (- common) | G70V-ZOM16P-1-C4 | ||
--- * | Every 4 points internally connected at terminal block middle row | NPN (+ common) | G70V-ZOM16P-C4-D | |
PNP (- common) | G70V-ZOM16P-1-C4-D |
Note: 1. Relays are not mounted to the G70V-ZID16P(-1)(-C16) I/O Terminal Sockets. Combine the I/O Terminal Sockets with Slim I/O Relays.
2. Relays are not mounted to the G70V-ZOM16P(-1)(-C4) I/O Terminal Sockets. Combine the I/O Terminal Sockets with Slim I/O Relays or Slim I/O SSRs.
* The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL).
2. Relays are not mounted to the G70V-ZOM16P(-1)(-C4) I/O Terminal Sockets. Combine the I/O Terminal Sockets with Slim I/O Relays or Slim I/O SSRs.
* The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL).
Options (Order Separately)
Mountable Relays
Applicable I/O Relay Terminal | Classification | Type | Model | ||
G70V-SID16P(-1)(-C16) G70V-ZID16P(-1)(-C16) | Input | Slim I/O Relays *1 | G2RV-1-S-AP-G DC21 | ||
G70V-SOC16P(-1)(-C4) G70V-ZOM16P(-1)(-C4) | Output | Slim I/O Relays | No Latching Lever *2 | G2RV-1-S-G DC21 | |
Latching Lever | G2RV-1-SI-G DC21 | ||||
Slim I/O SSRs | For AC | Zero cross function | G3RV-202S DC24 | ||
No zero cross function | G3RV-202SL DC24 | ||||
For DC | G3RV-D03SL DC24 | ||||
G70V-ZOM16P(-1)-C4-D *3 | Output | Slim I/O SSRs | For DC | G3RV-D03SL DC24 |
Note: When using Slim I/O SSRs, either remove the Slim I/O Relays from the output G70V-SOC16P(-1)(-C16) to mount them, or order the output G70V-ZOM16P(-1)(-C16) I/O Terminal Sockets and the Slim I/O SSRs separately and combine them.
*1. G2RV-1-S-AP-G Slim I/O Relays are mounted to G70V-SID16P(-1)(-C16) I/O Relay Terminals as a standard feature.
*2. G2RV-1-S-G Slim I/O Relays are mounted to G70V-SOC16P(-1)(-C4) I/O Relay Terminals as a standard feature.
*3. The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL).
When ordering, designate the rated voltage.
*1. G2RV-1-S-AP-G Slim I/O Relays are mounted to G70V-SID16P(-1)(-C16) I/O Relay Terminals as a standard feature.
*2. G2RV-1-S-G Slim I/O Relays are mounted to G70V-SOC16P(-1)(-C4) I/O Relay Terminals as a standard feature.
*3. The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL).
When ordering, designate the rated voltage.
Cables for I/O Relay Terminals XW2Z-R
• Cable with Loose Wire and Crimp Terminals: XW2Z-RY[]C
• Cable with Loose Wires: XW2Z-RA[]C
• Cable with connectors
• Fujitsu/Otax connectors (1:1): XW2Z-R[]C
• Fujitsu/Otax connectors (1:2):
XW2Z-RI[]C-[]
XW2Z-RO[]C-[]
• Fujitsu/Otax connectors (1:3): XW2Z-R[]C-[]-[]
• MIL connectors (1:1):
XW2Z-RI[]C
XW2Z-RO[]C
• MIL connectors (1:2):
XW2Z-RI[]-[]-D[]
XW2Z-RM[]-[]-D[]
XW2Z-RO[]-[]-D1
Refer to Connecting Cables on Data Sheet for details.
• Cable with Loose Wires: XW2Z-RA[]C
• Cable with connectors
• Fujitsu/Otax connectors (1:1): XW2Z-R[]C
• Fujitsu/Otax connectors (1:2):
XW2Z-RI[]C-[]
XW2Z-RO[]C-[]
• Fujitsu/Otax connectors (1:3): XW2Z-R[]C-[]-[]
• MIL connectors (1:1):
XW2Z-RI[]C
XW2Z-RO[]C
• MIL connectors (1:2):
XW2Z-RI[]-[]-D[]
XW2Z-RM[]-[]-D[]
XW2Z-RO[]-[]-D1
Refer to Connecting Cables on Data Sheet for details.
Labels
Appearance | Model | Minimum order (sheet) (quantity per sheet) |
XW5Z-P2.5LB2 | 5 (1 sheet / 72 pieces) |
Accessories for DIN Track Mounting
Appearance | Name | Model | Minimum order (quantity) | |
DIN Tracks | 1 m | PFP-100N | 1 | |
0.5 m | PFP-50N | |||
End Plate | PFP-M * | 10 | ||
Spacer | PFP-S * |