I/O Relay Terminal
G70V
Our Value Design Products Increase the Value of Your Control Panels. I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor.
Specifications
Coil Ratings (Common to Input/Output per Relay)
Rated voltage (V) | Rated current (mA) | Coil resistance (Ω) | Must operate of rated voltage | Must release of rated voltage | Maximum voltage of rated voltage | Power consumption (mW) |
24 VDC | 13.3 | 1575 | 80% max. | 10% min. | 110% | Approx. 280 |
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±15% for coil resistance.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The value for maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’s operating power supply. Continuous operation at this voltage is not within product specifications.
4. The rated current includes the current for the indicators on the I/O Relay Terminal.
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±15% for coil resistance.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The value for maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’s operating power supply. Continuous operation at this voltage is not within product specifications.
4. The rated current includes the current for the indicators on the I/O Relay Terminal.
Contact Ratings (G2RV-1-S-G I/O Relay)
Item | For input | For output | |
Resistive load (cosφ=1) | Resistive load (cosφ=1) | Inductive load (cosφ=0.4 L/R=7 ms) | |
Rated load | 50 mA at 30 VAC 50 mA at 36 VDC | 6 A at 250 VAC 6 A at 30 VDC | 2.5 A at 250 VAC 2 A at 30 VDC |
Rated carry current | 50 mA | 6 A/point, 10 A/common | |
Max. switching voltage | 30 VAC, 36 VDC | 250 VAC, 125 VDC | |
Max. switching current | 50 mA | 6 A/point, 10 A/common | |
Maximum switching capacity | --- | 1,500 VA 180 W | 500 VA 60 W |
Error rate (reference value) * | 1 mA at 100 mVDC | 10 mA at 5 VDC | |
Electrical endurance | 5,000,000 operations min. | NO contacts: 70,000 operations min. NC contacts: 50,000 operations min. | |
Mechanical endurance | 5,000,000 operations min. | 5,000,000 operations min. |
* The above values are for a switching frequency of 120 operations/min.
Characteristics
Item | G70V-SID16P(-1)(-C16) (Input, DC coil) | G70V-SOC16P(-1)(-C4) (output, DC coil) | |
Contact form | SPST-NO × 16 | SPDT × 16 | |
Contact material | Ag alloy + Au plating | Ag alloy | |
Contact resistance *1 | 150 mΩ max. | ||
Must Operate time *2 | 20 ms max. | ||
Release time *2 | 40 ms max. | ||
Max. switching frequency | Mechanical limit | 18,000 operations/h | |
At rated load | 1,800 operations/h (under rated load) | ||
Insulation resistance | 100 MΩ min. | ||
Dielectric strength | Between coil and contacts: 2,500 VAC for 1 min | ||
Vibration resistance | 100 m/s2 | ||
Shock resistance | 100 m/s2, 3 times each in 6 directions along 3 axes | ||
Noise immunity | Noise level: 1.5 kV; pulse width: 100 ns to 1 μs | ||
Ambient operating temperature | -40 to 55°C (with no icing or condensation) | ||
Ambient operating humidity | 35% to 85% | ||
LED color | Power supply | Green | |
I/O | Yellow | ||
Weight | Approx. 350 g | Approx. 370 g |
Note: The above values are initial values.
*1. Measurement: 1 A at 5 VDC.
*2. Ambient temperature: 23°C.
*1. Measurement: 1 A at 5 VDC.
*2. Ambient temperature: 23°C.
Approved Standards
The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use.
UL standard certification (File No. E95399)
Type | Model | Ratings | Standard number | Category | Listed/ Recognized | Contact ratings |
I/O Relay Terminal | G70V-SID16P(-1) | 24V DC | USL: UL 61010-1-12 CNL: UL 61010-2-201 | NRAQ, NRAQ7 | Listed | 24V DC |
G70V-SID16P(-1)-C16 | ||||||
G70V-SOC16P(-1) | 250V AC / 30V DC Resistive 4A at 40°C | |||||
G70V-SOC16P(-1)-C4 | ||||||
I/O Terminal Sockets | G70V-ZID16P(-1) | Recognized | 24V DC | |||
G70V-ZID16P(-1)-C16 | ||||||
G70V-ZOM16P(-1) | 250V AC / 30V DC Resistive 4A at 40°C | |||||
G70V-ZOM16P(-1)-C4 | ||||||
G70V-ZOM16P(-1)-C4-D |
Note:
1. USL refers to certification in the US, and CNL refers to certification in Canada.
2. cULus certification has been obtained in Canada. (CAN/CSA-C22.2 No. 61010-2-201)
1. USL refers to certification in the US, and CNL refers to certification in Canada.
2. cULus certification has been obtained in Canada. (CAN/CSA-C22.2 No. 61010-2-201)
G70V-SOC16P(-1): UL certification specifications
TÜV Rheinland certification (Certification No. R50327604)
Type | Model | Ratings | Standard number | Operating coil | Contact ratings |
I/O Relay Terminal | G70V-SID16P(-1) | 24V DC | EN 61810-1 | 24V DC | 24V DC 0.05A L/R=0ms |
G70V-SID16P(-1)-C16 | |||||
G70V-SOC16P(-1) | single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C) 16 loads: 30V DC 5A L/R=0ms (Ta=+25°C) | ||||
G70V-SOC16P(-1)-C4 | 250V AC / 30V DC 16 loads: 5A (Ta=+25°C) 16 loads: 3A (Ta=+55°C) 1 load: 6A Resistive load total max. 10A common line | ||||
I/O Terminal Sockets | G70V-ZID16P(-1) | 24V DC | EN 61810-1 | 24V DC | 24V DC 0.05A L/R=0ms |
G70V-ZID16P(-1)-C16 | |||||
G70V-ZOM16P(-1) | single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C) 16 loads: 30V DC 5A L/R=0ms (Ta=+25°C) | ||||
G70V-ZOM16P(-1)-C4 | 250V AC / 30V DC 16 loads: 5A (Ta=+25°C) 16 loads: 3A (Ta=+55°C) 1 load: 6A Resistive load total max. 10A common line | ||||
G70V-ZOM16P(-1)-C4-D |
CE Marking Compliance
Model | EMC Directive | Low Voltage Directive | Machinery Directive |
G70V | Not applicable | ❍ | Not applicable |
Note:
1. The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components.
2. Details and other information on conformity levels are issued as part of the "EU Declaration of Conformity." Please contact your OMRON representative for more information.
1. The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components.
2. Details and other information on conformity levels are issued as part of the "EU Declaration of Conformity." Please contact your OMRON representative for more information.