I/O Terminal Socket
P7TF-IS16 / OS16 / OS08
I/O Terminal Sockets to Flexibly Build Systems
I/O Terminal Sockets
When ordering, specify the rated voltage.
I/O classification | I/O points | Internal I/O common | Rated voltage | Model |
For inputs | 16 | NPN (- common) | 12 VDC | P7TF-IS16 DC12 |
24 VDC | P7TF-IS16 DC24 | |||
100/110 VDC | P7TF-IS16 DC100/110 | |||
100/110 VAC | P7TF-IS16 AC100/110 | |||
200/220 VAC | P7TF-IS16 AC200/220 | |||
For outputs | NPN (+ common) | 12 VDC | P7TF-OS16 DC12 | |
24 VDC | P7TF-OS16 DC24 | |||
PNP (- common) | 12 VDC | P7TF-OS16-1 DC12 | ||
24 VDC | P7TF-OS16-1 DC24 | |||
8 | NPN (+ common) | 12 VDC | P7TF-OS08 DC12 | |
24 VDC | P7TF-OS08 DC24 |
Accessories (Order Separately)
Cables for I/O Relay Terminals
• Cables with Loose Wires and Crimp Terminals: XW2Z-RY[]C
• Cables with Loose Wires: XW2Z-RA[]C
• Cables with Connectors: XW2Z-R[]C-[]-[]
• Cables with Connectors (1:2): XW2Z-RO[]C-[] and XW2Z-RI[]C-[]
• Cables with Connectors (1:1): XW2Z-R[]C
Refer to the XW2Z-R Datasheet for details.
• Cables with Loose Wires: XW2Z-RA[]C
• Cables with Connectors: XW2Z-R[]C-[]-[]
• Cables with Connectors (1:2): XW2Z-RO[]C-[] and XW2Z-RI[]C-[]
• Cables with Connectors (1:1): XW2Z-R[]C
Refer to the XW2Z-R Datasheet for details.
Shorting Bar
Model |
G78-04 |
Output Short-Circuit Module
Model |
G77-S |
Sockets
Model |
P7TF-05 |
Indicator Module (with Surge Suppressing Function)
Type | Applicable relay coil voltage | Model | Remarks |
For AC Relays | 100 (110) VAC | P70A AC100/110 | Varistors |
200 (220) VAC | P70A AC200/220 | ||
For DC Relays | 12/24 VDC | P70D DC12/24 | Diodes |
Note: 1. Order the Indicator Module that is suited to the Relay coil voltage.
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. The input current is as given below (reference values).
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA
4. Weight: Approx. 6 g
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. The input current is as given below (reference values).
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA
4. Weight: Approx. 6 g
Accessories for DIN Track Mounting
Refer to your OMRON website for details on the PFP-[].
Mountable I/O Relays
I/O classification | Rated coil voltage | Contact structure | Case color | Rated load (resistive load) | Model |
For inputs | 12 VDC | SPST-NO | Transparent green | 1 A at 24 VDC 1 A at 110 VAC | G7T-1122S DC12 * |
24 VDC | G7T-1122S DC24 * | ||||
100/110 VDC | G7T-1122S DC100/110 * | ||||
100/110 VAC | Transparent red | G7T-1122S AC100/110 * | |||
200/220 VAC | G7T-1122S AC200/220 * | ||||
For outputs | 12 VDC | Transparent | 5 A at 24 VDC 2 A at 220 VAC | G7T-1112S DC12 * | |
24 VDC | G7T-1112S DC24 * | ||||
12 VDC | SPST-NC | G7T-1012S DC12 | |||
24 VDC | G7T-1012S DC24 |
Mountable I/O SSRs
I/O classification | Rated input voltage | Isolation | Operation indicator | Zero cross function | Applicable load | Model |
For inputs | 5 to 24 VDC | Photocoupler | Yes | --- | Logic level supply current: 25 mA | G3TA-IDZR02S-US DC5-24 |
4 to 24 VDC | No | G3TA-IDZR02SM-US | ||||
100 to 240 VAC | Yes | G3TA-IAZR02S-US AC100-240 | ||||
For outputs | 12 VDC | Phototriac | Yes | Yes | 2 A at 100 to 240 VAC | G3TA-OA202SZ-US DC12 |
24 VDC | G3TA-OA202SZ-US DC24 | |||||
12 VDC | No | G3TA-OA202SL-US DC12 | ||||
24 VDC | G3TA-OA202SL-US DC24 | |||||
12 VDC | Photocoupler | --- | 2 A at 5 to 48 VDC | G3TA-ODX02S-US DC12 | ||
24 VDC | G3TA-ODX02S-US DC24 | |||||
12 VDC | 1 A at 48 to 200 VDC | G3TA-OD201S-US DC12 | ||||
24 VDC | G3TA-OD201S-US DC24 |
Note: "For inputs" and "for outputs" indicate the I/O relationship to a PLC.
Input Relays and SSRs are mainly suitable for input signals to a PLC or other device. Output Relays are mainly suitable to switching loads that receive output signals from a PLC or other device. The Input and Output Relays and SSRs have different switching performances. Select a suitable Relay for the application.
* Mounted as standard features to G7TC I/O Relay Terminals.
Input Relays and SSRs are mainly suitable for input signals to a PLC or other device. Output Relays are mainly suitable to switching loads that receive output signals from a PLC or other device. The Input and Output Relays and SSRs have different switching performances. Select a suitable Relay for the application.
* Mounted as standard features to G7TC I/O Relay Terminals.