Photoelectric Sensor with Built-in Amplifier
E3S
General-purpose Photoelectric Sensor for High Quality and Reliable Detection
Sensing method |
Through-beam |
Retro-reflective |
|||||
Model |
E3S-2E4 |
E3S-5E4 |
E3S-R2E4 |
||||
Sensing distance |
2 m |
5 m |
0.1 to 2 m |
||||
Standard sensing object |
Opaque: 7-mm dia. min. |
Opaque: 11-mm dia. min. |
Opaque: 30-mm dia. min. |
||||
Differential travel |
--- |
||||||
Directional angle |
Both emitter and receiver: 3° to 10° |
3° to 10° |
|||||
Light source (wavelength) |
Infrared LED (950 nm) |
||||||
Power supply voltage |
12 to 24 VDC±10%, ripple (p-p): 10% max. |
||||||
Current consumption |
50 mA max. (Emitter: 25 mA max., Receiver: 25 mA max.) |
40 mA max. |
|||||
Control output |
Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) |
||||||
Response time |
Operate or reset: 3 ms max. |
Operate or reset: 1 ms max. |
|||||
Sensitivity adjustment |
With an indicator |
||||||
Ambient illumination |
Incandescent lamp: 3,000 lx max. |
||||||
Ambient temperature |
Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) |
||||||
Ambient humidity |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
||||||
Insulation resistance |
20 MΩ min. at 500 VDC |
||||||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
||||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2 3 times each in X, Y, and Z directions |
||||||
Degree of protection |
IEC IP65 |
IEC IP67 |
|||||
Connection method |
Pre-wired cable (standard length: 2 m) |
||||||
Indicators |
Light indicator (red), Stability indicator (green) |
||||||
Material |
Case |
Polybutylene terephthalate |
Zinc die-cast |
||||
Lens * |
Polycarbonate |
||||||
Mounting Bracket |
Iron |
||||||
Sensing method |
Diffuse-reflective |
Convergent-reflective |
|||||
Model |
E3S-DS10E4 |
E3S-DS30E41 |
E3S-DS30E4S |
E3S-LS10XE4 |
E3S-LS20XE4 |
||
Sensing distance |
100 mm (white |
300 mm (white paper 100 x 100) |
30 to 100 mm |
50 to 250 mm |
|||
Standard sensing |
Transparent, opaque |
||||||
Differential travel |
20% max. of setting distance |
1.5 mm max. at |
5% max. at 50 to |
||||
10 mm max. at |
|||||||
Directional angle |
--- |
||||||
Light source |
Infrared LED (950 nm) |
RED LED |
Infrared LED |
||||
Power supply voltage |
12 to 24 VDC±10%, ripple (p-p): 10% max. |
||||||
Current consumption |
40 mA max. |
||||||
Control output |
Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) |
||||||
Response time |
Operate or reset: 1 ms max. |
||||||
Sensitivity adjustment |
With an indicator |
||||||
Ambient illumination |
Incandescent lamp: 3,000 lx max. |
||||||
Ambient temperature |
Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) |
||||||
Ambient humidity |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
||||||
Insulation resistance |
20 MΩ min. at 500 VDC |
||||||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
||||||
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2 3 times each in X, Y, and Z directions |
||||||
Degree of protection |
IEC IP65 |
IEC IP67 |
|||||
Connection method |
Pre-wired cable (standard length: 2 m) |
||||||
Indicators |
Light indicator (red), Stability indicator (green) |
||||||
Material |
Case |
Polybutylene |
Zinc die-cast |
||||
Lens * |
Polycarbonate |
||||||
Mounting |
Iron |
||||||
* The ambient operating illumination is the illumination that changes the output ±20% at 200 lx. It is not the operational
limit.