Light Units
FLV Series
Ring Light, Bar Light and Spot Light. Light Series Approx. 200 Models.
Camera-mount Lighting Controller for FLV Series
FLV-TCC Series
Model |
FLV-TCC4 |
FLV-TCC1 |
|||
Number of channels |
4 standard lights |
1 standard light |
|||
Applicable light *1 |
FLV series (excluding FLV-EP series and FLV-LN series) |
||||
Applicable camera *2 |
FH-S series, FZ-S series |
||||
Applicable vision system controller |
FH series |
||||
Input voltage |
Supplied from applicable camera (12 V) or external power supply |
||||
External power supply voltage |
24 VDC 10% (including ripple) |
||||
Current consumption |
1.5A max. |
||||
Recommended |
S8VS-06024 (manufactured by OMRON, 24 VDC, 2.5 A, 60 W) |
||||
Power of |
12 VDC |
Continuous lighting |
4ch total 7.5 W max. |
7.5 W max. |
|
Trigger |
Simultaneous |
4ch total 7.5 W max. |
7.5 W max. |
||
Individual |
7.5 W max. for 1ch |
||||
24 VDC |
Continuous lighting |
4ch total 7.5 W max. |
7.5 W max. |
||
Trigger |
Simultaneous |
4ch total 15 W max. |
15 W max. |
||
Individual |
15 W max. for 1ch |
||||
Drive method |
Constant voltage method |
||||
Lighting method |
Trigger lighting, Continuous lighting |
||||
Luminance control method |
Duty light adjustment or voltage light adjustment |
||||
Trigger lighting |
Lighting in synchronization with trigger input timing from the |
||||
Trigger lighting delay time |
Ton: 30μs max. |
||||
Lighting duration setting |
Auto setting in accordance with shutter speed. |
||||
External interface |
Camera connection cable (directly connected with the main unit) |
||||
Insulation resistance |
0.5 MΩ (100VDC) |
||||
Ambient temperature |
Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or |
||||
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
||||
Degree of protection |
IP20 (IEC60529) |
||||
Vibration resistance (destructive) |
10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and |
||||
Shock resistance (destructive) |
150 m/s2 3 times each in 6 directions(up/down, left/right, forward/ |
||||
Materials |
Case,Camera mount plate: Aluminum, Cable: FPVC |
||||
Weight |
Approx. 130g (including |
Approx. 120g (including |
|||
Accessories |
Instruction sheet, Lighting connection table, Camera Mount plate, |
||||
Applicable standards |
EN61326-1 *4, KC |
||||
Model |
FLV-TCC3HB |
FLV-TCC1EP |
|||
Number of channels |
1 Spot Light, |
1 Spot Light |
|||
Applicable light *1 |
FLV series (excluding FLV-LN |
FLV-EP series |
|||
Applicable camera *2 |
FH-S series, FZ-S series |
||||
Applicable vision system controller |
FH series |
||||
Input voltage |
Supplied from applicable camera (12 |
Supplied from applicable |
|||
External power supply voltage |
24 VDC 10% (including ripple) |
⎯ |
|||
Current consumption |
1.5A max. |
1.0A max. |
|||
Recommended |
S8VS-06024 (manufactured by |
⎯ |
|||
Power of |
12 VDC |
Continuous lighting |
0ch connection: 1,2ch |
All FLV-EP series |
|
Trigger |
Simultaneous |
0ch connection: |
|||
Individual |
7.5 W max. for 1ch |
||||
24 VDC |
Continuous lighting |
0ch connection: |
⎯ |
||
Trigger |
Simultaneous |
0ch connection: |
|||
Individual |
15 W max. for 1ch |
||||
Drive method |
0ch Constant current method 1ch/ |
Constant current method |
|||
Lighting method |
Trigger lighting, Continuous lighting |
||||
Luminance control method |
0ch Duty light adjustment or current |
Duty light adjustment or |
|||
Trigger lighting |
Lighting in synchronization with trigger input timing from the |
||||
Trigger lighting delay time |
Ton: 30μs max. |
||||
Lighting duration setting |
Auto setting in accordance with shutter speed. |
||||
External interface |
Camera connection cable (directly connected with the main unit) |
||||
Insulation resistance |
0.5 MΩ (100VDC) |
||||
Ambient temperature |
Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or |
||||
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
||||
Degree of protection |
IP20 (IEC60529) |
||||
Vibration resistance (destructive) |
10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and |
||||
Shock resistance (destructive) |
150 m/s2 3 times each in 6 directions(up/down, left/right, forward/ |
||||
Materials |
Case,Camera mount plate: Aluminum, Cable: FPVC |
||||
Weight |
Approx. 130g (including |
Approx. 120g (including |
|||
Accessories |
Instruction sheet, Lighting connection table, Camera Mount plate, |
||||
Applicable standards |
EN61326-1 *4, KC |
1. Check the lighting connection table of accessory.
2. When mounting on the FH-S[]12, use the FH-SM12-XLC (sold separately).
3. When supplying the power to this product from an external input power supply (24V), make sure to turn ON the power to this product first or at the same time with the vision system controller. If you reverse this order, this product will not recognize the 24V external input, so lighting greater than 7.5W will not be possible.
4. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.
Analog Lighting Controller for FLV Series
FLV-ATC Series
Lighting Controller for Standard Light FLV-ATC21024/-ATC41024
Model |
FLV-ATC21024-[] *1 |
FLV-ATC41024-[] *1 |
Number of channels |
2 |
4 |
Applicable light |
FLV series (FLV-EP series and FLV-LN series are excluded.) |
|
Power supply voltage *2 |
100 to 240 VAC, 50/60 Hz |
|
Current consumption |
1 A max. |
|
Power of connected light |
2ch total 40 W max. |
4ch total 40 W max. |
Drive method |
Constant voltage method |
|
Lighting method |
Trigger lighting, Continuous lighting |
|
Luminance control method |
Voltage light adjustment: 14.0 to 24.0 V |
|
Trigger lighting |
Lighting in synchronization with input from the trigger input terminal |
|
Trigger lighting delay time |
T_on: 100 μs max. |
|
External interface |
Trigger input terminal block |
|
Dielectric strength |
1500 VAC 50/60 Hz 1 min |
|
Insulation resistance |
20 MΩ (500 VDC) |
|
Ambient temperature |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) |
|
Ambient humidity |
Operating/storage: 35% to 85% (with no condensation) |
|
Degree of protection |
IP20 (IEC60529) |
|
Vibration resistance (destructive) |
10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions |
|
Shock resistance (destructive) |
150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward) |
|
Materials |
Case: Aluminum |
|
Weight |
Approx. 800 g |
|
Accessories |
Instruction sheet, AC input cable *1 |
|
Applicable standards |
EN61326-1 *3 |
1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.
Lighting Controller for Spot Light FLV-ATC10405/-ATC40405
Model |
FLV-ATC10405-[] *1 |
FLV-ATC40405-[] *1 |
Number of channels |
1 |
4 |
Applicable light |
FLV-EP series |
|
Power supply voltage *2 |
100 to 240 VAC, 50/60 Hz |
|
Current consumption |
0.6 A max. |
|
Power of connected light |
3 W max. |
4ch total 12 W max. |
Drive method |
Constant current method |
|
Lighting method |
Trigger lighting, Continuous lighting |
|
Luminance control method |
Current light adjustment: 5 A max. |
|
Trigger lighting |
Turning the light off in synchronization with input from the trigger input terminal |
|
Trigger lighting delay time |
T_on: 1000 μs max. |
|
External interface |
Trigger input terminal block |
|
Dielectric strength |
1500 VAC 50/60 Hz 1 min |
|
Insulation resistance |
20 MΩ (500 VDC) |
|
Ambient temperature |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) |
|
Ambient humidity |
Operating/storage: 35% to 85% (with no condensation) |
|
Degree of protection |
IP20 (IEC60529) |
|
Vibration resistance (destructive) |
10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions |
|
Shock resistance (destructive) |
150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward) |
|
Materials |
Case: Aluminum |
|
Weight |
Approx. 800 g |
|
Accessories |
Instruction sheet, AC input cable *1 |
|
Applicable standards |
EN61326-1 *3 |
1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.
Lighting Controller for Line Light: FLV-ATC26024-100V/-200V
Model |
FLV-ATC26024-100V[] *1 |
FLV-ATC26024-200V[] *1 |
Number of channels |
2 |
|
Applicable light |
FLV-LN series |
|
Power supply voltage *2 |
100 to 120 VAC, 50/60 Hz |
200 to 240 VAC, 50/60 Hz |
Current consumption |
7 A max. |
4 A max. |
Power of connected light |
2ch total 240 W max. |
|
Drive method |
Constant voltage method |
|
Lighting method |
Trigger lighting, Continuous lighting |
|
Intensity control method |
Current light adjustment: 5 A max. |
|
Luminance control method |
Turning the light off in synchronization with input from the trigger input terminal |
|
Trigger lighting delay time |
T_on: 500 μs max. |
|
External interface |
Trigger input terminal block |
|
Dielectric strength |
1500 VAC 50/60 Hz 1 min |
|
Insulation resistance |
20 MΩ (500 VDC) |
|
Ambient temperature |
Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation) |
|
Ambient humidity |
Operating/storage: 35% to 85% (with no condensation) |
|
Degree of protection |
IP20 (IEC60529) |
|
Vibration resistance (destructive) |
10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions |
|
Shock resistance (destructive) |
150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward) |
|
Materials |
Case: Aluminum |
|
Weight |
Approx. 2.1 kg |
|
Accessories |
Instruction sheet, AC input cable *1 |
|
Applicable standards |
EN61326-1 *3 |
1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.
Digital Lighting Controller for FLV Series
3Z4S-LT IDGB Series
Model |
3Z4S-LT IDGB-50M2-L01-L |
3Z4S-LT IDGB-150M4-L01-L |
Rated capacity |
46 W |
144 W |
Number of channels |
2 |
4 |
Applicable light |
FLV Series (excluding FLV-EP Series and FLV-LN Series) |
|
Power supply voltage |
24 VDC±5% |
|
Current consumption |
2.08 A max. |
6.25 A max. |
Power of connected light *1 |
2 ch total 46 W max. |
4 ch total 144 W max. |
|
||
Drive method |
Constant voltage method |
|
Lighting method |
Continuous lighting |
|
Luminance control method |
PWM light adjustment |
|
Light adjustment |
256 levels (Duty ratio of 0 to 100% at a lighting frequency of 125 kHz) *3 |
|
Delay time |
0 to 9,000 μs in 1 μs increments |
|
External ON/OFF response *2 |
High mode --- OFF → ON: 40 μs or less, ON → OFF: 10 μs or less |
|
Ambient temperature |
Operating: 0 to 50 °C, Storage: -20 to 65 °C, (with no icing or condensation) |
|
Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
|
Cooling method |
Natural air cooling |
Forced air cooling |
Weight |
Approx. 700 g |
Approx. 1,000 g |
Overvoltage category |
Category I |
|
Applicable standards |
EMC Directives: EN 55011 Group 1 Class A, EN 61000-6-2 |
|
Environmental regulation |
Conforms to RoHS Directive |
|
Pollution degree |
2 |
1. When connecting lights to multiple channels, make sure that the total power consumption of the connected lights is within the specification of the lighting controller.
2. Measured with a rated light connected.
3. There will be some variation in light adjustment between units when the level is set between 0 and 15 or between 250 and 255.