Product Category

Light Units

FLV Series

Ring Light, Bar Light and Spot Light. Light Series Approx. 200 Models.

Camera-mount Lighting Controller for FLV Series
 FLV-TCC Series

Model

FLV-TCC4

FLV-TCC1

Number of channels

4 standard lights

1 standard light

Applicable light *1

FLV series (excluding FLV-EP series and FLV-LN series)

Applicable camera *2

FH-S series, FZ-S series

Applicable vision system controller

FH series

Input voltage

Supplied from applicable camera (12 V) or external power supply
 (24 V) *3

External power supply voltage

24 VDC 10% (including ripple)

Current consumption

1.5A max.


Recommended
 power supply

S8VS-06024 (manufactured by OMRON, 24 VDC, 2.5 A, 60 W)

Power of
 connected
 light

12 VDC
 for
 camera
 supply

Continuous lighting

4ch total 7.5 W max.

7.5 W max.

Trigger
 lighting

Simultaneous
 lighting

4ch total 7.5 W max.

7.5 W max.

Individual
 lighting

7.5 W max. for 1ch

24 VDC
 for
 external
 supply

Continuous lighting

4ch total 7.5 W max.

7.5 W max.

Trigger
 lighting

Simultaneous
 lighting

4ch total 15 W max.

15 W max.

Individual
 lighting

15 W max. for 1ch

Drive method

Constant voltage method

Lighting method

Trigger lighting, Continuous lighting

Luminance control method

Duty light adjustment or voltage light adjustment
 Duty light adjustment: PWM frequency of 100 kHz, light adjustment
 of 255 levels
 Voltage light adjustment: Light adjustment of 255 levels
 (all are configured with vision system controller)

Trigger lighting

Lighting in synchronization with trigger input timing from the
 controller.

Trigger lighting delay time

Ton: 30μs max.

Lighting duration setting

Auto setting in accordance with shutter speed.

External interface

Camera connection cable (directly connected with the main unit)

Insulation resistance

0.5 MΩ (100VDC)

Ambient temperature

Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or
 condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Degree of protection

IP20 (IEC60529)

Vibration resistance (destructive)

10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and
 Z directions

Shock resistance (destructive)

150 m/s2 3 times each in 6 directions(up/down, left/right, forward/
 backward)

Materials

Case,Camera mount plate: Aluminum, Cable: FPVC

Weight

Approx. 130g (including
 the camera mount plate)

Approx. 120g (including
 the camera mount plate)

Accessories

Instruction sheet, Lighting connection table, Camera Mount plate,
 Mounting screws (M2 set screw x 4, M2 flat head screw x 4, M4 flat
 head screw x 4)

Applicable standards

EN61326-1 *4, KC

Model

FLV-TCC3HB

FLV-TCC1EP

Number of channels

1 Spot Light,
 2 standard lights

1 Spot Light

Applicable light *1

FLV series (excluding FLV-LN
 series)

FLV-EP series

Applicable camera *2

FH-S series, FZ-S series

Applicable vision system controller

FH series

Input voltage

Supplied from applicable camera (12
 V) or external power supply (24 V) *3

Supplied from applicable
 camera (12 V)

External power supply voltage

24 VDC 10% (including ripple)

Current consumption

1.5A max.

1.0A max.


Recommended
 power supply

S8VS-06024 (manufactured by
 OMRON, 24 VDC, 2.5 A, 60 W)

Power of
 connected
 light

12 VDC
 for
 camera
 supply

Continuous lighting

0ch connection: 1,2ch
 total 5.5 W max.
 0ch non-connection:
 1,2ch total 7.5 W max.

All FLV-EP series
 can be connected.

Trigger
 lighting

Simultaneous
 lighting

0ch connection:
 1,2ch total 5.5 W max.
 0ch non-connection:
 1,2ch total 7.5 W max.

Individual
 lighting

7.5 W max. for 1ch

24 VDC
 for
 external
 supply

Continuous lighting

0ch connection:
 1,2ch total 5.5 W max.
 0ch non-connection:
 1,2ch total 7.5 W max.

Trigger
 lighting

Simultaneous
 lighting

0ch connection:
 1,2ch total 14 W max.
 0ch non-connection:
 1,2ch total 15 W max.

Individual
 lighting

15 W max. for 1ch

Drive method

0ch Constant current method 1ch/
 2ch: Constant voltage method

Constant current method

Lighting method

Trigger lighting, Continuous lighting

Luminance control method

0ch Duty light adjustment or current
 light adjustment 1ch/2ch Duty light
 adjustment or voltage light
 adjustment
 Duty light adjustment: PWM frequency
 of 100 kHz, light adjustment of 255
 levels current light adjustment/
 Voltage light adjustment: Light
 adjustment of 255 levels (all are
 configured with vision system
 controller)

Duty light adjustment or
 current light adjustment
 Duty light adjustment:
 PWM frequency of 100 kHz,
 light adjustment of 255
 levels current light
 adjustment: Light
 adjustment of 255 levels
 (all are configured with
 vision system controller)

Trigger lighting

Lighting in synchronization with trigger input timing from the
 controller.

Trigger lighting delay time

Ton: 30μs max.

Lighting duration setting

Auto setting in accordance with shutter speed.

External interface

Camera connection cable (directly connected with the main unit)

Insulation resistance

0.5 MΩ (100VDC)

Ambient temperature

Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or
 condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Degree of protection

IP20 (IEC60529)

Vibration resistance (destructive)

10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and
 Z directions

Shock resistance (destructive)

150 m/s2 3 times each in 6 directions(up/down, left/right, forward/
 backward)

Materials

Case,Camera mount plate: Aluminum, Cable: FPVC

Weight

Approx. 130g (including
 the camera mount plate)

Approx. 120g (including
 the camera mount plate)

Accessories

Instruction sheet, Lighting connection table, Camera Mount plate,
 Mounting screws (M2 set screw x 4, M2 flat head screw x 4, M4 flat
 head screw x 4)

Applicable standards

EN61326-1 *4, KC

1. Check the lighting connection table of accessory.
 2. When mounting on the FH-S[]12, use the FH-SM12-XLC (sold separately).
 3. When supplying the power to this product from an external input power supply (24V), make sure to turn ON the power to this product first or at the same time with the vision system controller. If you reverse this order, this product will not recognize the 24V external input, so lighting greater than 7.5W will not be possible.
 4. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.

Analog Lighting Controller for FLV Series
 FLV-ATC Series

Lighting Controller for Standard Light FLV-ATC21024/-ATC41024

Model

FLV-ATC21024-[] *1

FLV-ATC41024-[] *1

Number of channels

2

4

Applicable light

FLV series (FLV-EP series and FLV-LN series are excluded.)

Power supply voltage *2

100 to 240 VAC, 50/60 Hz

Current consumption

1 A max.


Power of connected light

2ch total 40 W max.
 30 W max. for 1ch

4ch total 40 W max.
 30 W max. for 1ch

Drive method

Constant voltage method

Lighting method

Trigger lighting, Continuous lighting

Luminance control method

Voltage light adjustment: 14.0 to 24.0 V

Trigger lighting

Lighting in synchronization with input from the trigger input terminal

Trigger lighting delay time

T_on: 100 μs max.

External interface

Trigger input terminal block

Dielectric strength

1500 VAC 50/60 Hz 1 min

Insulation resistance

20 MΩ (500 VDC)

Ambient temperature

Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)

Ambient humidity

Operating/storage: 35% to 85% (with no condensation)

Degree of protection

IP20 (IEC60529)

Vibration resistance (destructive)

10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions

Shock resistance (destructive)

150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)

Materials

Case: Aluminum

Weight

Approx. 800 g

Accessories

Instruction sheet, AC input cable *1

Applicable standards

EN61326-1 *3

1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
 2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
 3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.

Lighting Controller for Spot Light FLV-ATC10405/-ATC40405

Model

FLV-ATC10405-[] *1

FLV-ATC40405-[] *1

Number of channels

1

4

Applicable light

FLV-EP series

Power supply voltage *2

100 to 240 VAC, 50/60 Hz

Current consumption

0.6 A max.

Power of connected light

3 W max.

4ch total 12 W max.
 3 W max. for 1ch

Drive method

Constant current method

Lighting method

Trigger lighting, Continuous lighting

Luminance control method

Current light adjustment: 5 A max.

Trigger lighting

Turning the light off in synchronization with input from the trigger input terminal

Trigger lighting delay time

T_on: 1000 μs max.

External interface

Trigger input terminal block

Dielectric strength

1500 VAC 50/60 Hz 1 min

Insulation resistance

20 MΩ (500 VDC)

Ambient temperature

Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)

Ambient humidity

Operating/storage: 35% to 85% (with no condensation)

Degree of protection

IP20 (IEC60529)

Vibration resistance (destructive)

10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions

Shock resistance (destructive)

150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)

Materials

Case: Aluminum

Weight

Approx. 800 g

Accessories

Instruction sheet, AC input cable *1

Applicable standards

EN61326-1 *3

1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
 2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
 3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.

Lighting Controller for Line Light: FLV-ATC26024-100V/-200V

Model

FLV-ATC26024-100V[] *1

FLV-ATC26024-200V[] *1

Number of channels

2

Applicable light

FLV-LN series

Power supply voltage *2

100 to 120 VAC, 50/60 Hz

200 to 240 VAC, 50/60 Hz

Current consumption

7 A max.

4 A max.

Power of connected light

2ch total 240 W max.
 120 W max. for 1ch

Drive method

Constant voltage method

Lighting method

Trigger lighting, Continuous lighting

Intensity control method

Current light adjustment: 5 A max.

Luminance control method

Turning the light off in synchronization with input from the trigger input terminal

Trigger lighting delay time

T_on: 500 μs max.

External interface

Trigger input terminal block

Dielectric strength

1500 VAC 50/60 Hz 1 min

Insulation resistance

20 MΩ (500 VDC)

Ambient temperature

Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation)

Ambient humidity

Operating/storage: 35% to 85% (with no condensation)

Degree of protection

IP20 (IEC60529)

Vibration resistance (destructive)

10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions

Shock resistance (destructive)

150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)

Materials

Case: Aluminum

Weight

Approx. 2.1 kg

Accessories

Instruction sheet, AC input cable *1

Applicable standards

EN61326-1 *3

1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix means type A.
 2. This product is the exclusive use for apparatus inclusion in the industrial machine field. This product cannot be used for the connection to electric power equipment, such as a common residence, store, and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
 3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) Also, the following condition is applied to the immunity test of this product. There are case that Lighting brightness fluctuate Max 10%.

Digital Lighting Controller for FLV Series
 3Z4S-LT IDGB Series

Model

3Z4S-LT IDGB-50M2-L01-L

3Z4S-LT IDGB-150M4-L01-L

Rated capacity

46 W

144 W

Number of channels

2

4

Applicable light

FLV Series (excluding FLV-EP Series and FLV-LN Series)

Power supply voltage

24 VDC±5%

Current consumption

2.08 A max.

6.25 A max.

Power of connected light *1

2 ch total 46 W max.
 46 W max. for 1 ch

4 ch total 144 W max.
 70 W max. for 1 ch

 image

Drive method

Constant voltage method

Lighting method

Continuous lighting

Luminance control method

PWM light adjustment

Light adjustment

256 levels (Duty ratio of 0 to 100% at a lighting frequency of 125 kHz) *3

Delay time

0 to 9,000 μs in 1 μs increments
 (Actual output will be delayed by the sum of the external ON/OFF response time
 described below and the set delay time.)

External ON/OFF response *2

High mode --- OFF → ON: 40 μs or less, ON → OFF: 10 μs or less
 Low mode --- OFF → ON: 10 μs or less, ON → OFF: 40 μs or less

Ambient temperature

Operating: 0 to 50 °C, Storage: -20 to 65 °C, (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Cooling method

Natural air cooling

Forced air cooling

Weight

Approx. 700 g

Approx. 1,000 g

Overvoltage category

Category I

Applicable standards

EMC Directives: EN 55011 Group 1 Class A, EN 61000-6-2

Environmental regulation

Conforms to RoHS Directive

Pollution degree

2

1. When connecting lights to multiple channels, make sure that the total power consumption of the connected lights is within the specification of the lighting controller.
 2. Measured with a rated light connected.
 3. There will be some variation in light adjustment between units when the level is set between 0 and 15 or between 250 and 255.