Cable Amplifier Proximity Sensor
E2EC
Sub miniature Sensors with Long-distance Detection
Model |
DC 2-Wire Models |
DC 3-Wire Models |
|||||
E2EC-CR8D[] |
E2EC-C1R5D[] |
E2EC-C3D[] |
E2EC-X4D[] |
E2EC-CR5C1 |
E2EC-C2R5C1 |
||
Sensing distance |
0.8 mm ±15% |
1.5 mm ±10% |
3 mm ±10% |
4 mm ±10% |
0.5 mm ±15% |
2.5 mm ±10% |
|
Set distance |
0 to 0.56 mm |
0 to 1.05 mm |
0 to 2.1 mm |
0 to 2.8 mm |
0 to 0.3 mm |
0 to 1.7 mm |
|
Differential travel |
10% max. of sensing distance |
||||||
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Data Sheet.) |
||||||
Standard sensing |
Iron, 5 × 5 × 1 mm |
Iron, 8 × 8 |
Iron, 12 × 12 |
Iron, 5 × 5 |
Iron, 8 × 8 × |
||
Response frequency |
1.5 kHz |
1 kHz |
|||||
Power supply voltage |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
5 to 24 VDC (4.75 to 30 VDC), |
|||||
Current |
--- |
10 mA max. |
|||||
Leakage current |
0.8 mA max. |
--- |
|||||
Control |
Load |
5 to 100 mA |
NPN open-collector output, |
||||
Residual |
3 V max. (Load current: 100 mA, Cable length: 2 m) |
1 V max. (Load current: |
|||||
Indicators |
D1 Models: Operation indicator (red), Setting indicator (green) |
Detection indicator (red) |
|||||
Operation mode |
D1 Models: NO |
NO |
|||||
Protection circuits |
Load short-circuit protection, Surge suppressor |
Surge suppressor |
|||||
Ambient |
Operating/Storage: -25 to 70°C (with no icing or condensation) *2 |
||||||
Ambient |
Operating/Storage: 35% to 95% (with no condensation) |
||||||
Temperature |
±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||||
Voltage influence |
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
±5% max. of sensing distance |
|||||
Insulation |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||||
Dielectric strength |
1,000 VAC for 1 min between current-carrying parts and case |
500 VAC for 1 min between |
|||||
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||||
Shock resistance |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
Destruction: 500 m/s2 10 times |
|||||
Degree of protection |
IEC 60529 IP67, In-house standards: oil-resistant (For Sensor Head only) |
IEC 60529 IP64 |
|||||
Connection method |
Pre-wired Models (Standard cable length: 2 m) |
||||||
Weight |
Approx. 45 g |
||||||
Materials |
Case |
Brass |
|||||
Sensing |
ABS |
||||||
Clamping |
--- |
Brass |
--- |
||||
Toothed |
--- |
Iron (zinc-plated) |
--- |
||||
Accessories |
Amplifier Mounting Bracket, Instruction manual |
Instruction manual |
1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
2. Incorrect operation may occur if there is a large temperature difference between the Sensor Head and the Amplifier Unit.