Long-distance Proximity Sensor

TL-LP / LY

Long-distance Model with a Sensing distance of 50 mm.

Model

TL-LP50

TL-LY50

Sensing distance

50 mm ± 10%

Set distance

0 to 40 mm

Differential travel

10% max. of sensing distance

Sensing object

Ferrous metals (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.)

Standard sensing object

Iron, 100 × 100 × 1 mm

Response time

15 ms max.

25 ms max.

Power supply
 voltage (operating
 voltage range * )

12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max.

100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Current consumption

10 mA max. (with no load)

---

Leakage current

---

Refer to Datasheet.

Control
 output

Switching
 capacity

NPN open collector with a maximum current of 200 mA at 30 VDC

10 to 200 mA

Residual
 voltage

3 V max. under a load current of 200 mA and a cable length of 2 m

Refer to Datasheet.

Indicators

Operation indicator (red)

Operation mode
 (with sensing object approaching)

NO. Refer to Datasheet.

Ambient temperature

Operating/Storage: - 25 to 70 ° C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

± 10% max. of sensing distance at 23 ° C in the temperature range of - 25 to 70 ° C

Voltage influence

± 2% max. of sensing distance within a range of ±10% of rated power supply voltage

Insulation resistance

50 M Ω min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

500 VAC (50/60 Hz) for 1min between current- carrying parts and case

2,000 VAC (50/60 Hz) for 1 min between current- carrying parts and case

Vibration resistance
 (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
 (destruction)

1,000m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC IP67

Connection method

Pre-wired Models (Standard cable length: 1 m)

Weight (packed state)

Approx. 1.4 kg

Materials

Case

Die-cast aluminum

Sensing
 surface

Polyester

Accessories

Instruction sheet

* Full-wave rectified power supplies with a mean output of 24 VDC ±10% are available for the TL-LP50.