Long-distance Proximity Sensor
TL-LP / LY
Long-distance Model with a Sensing distance of 50 mm.
Model |
TL-LP50 |
TL-LY50 |
|
Sensing distance |
50 mm ± 10% |
||
Set distance |
0 to 40 mm |
||
Differential travel |
10% max. of sensing distance |
||
Sensing object |
Ferrous metals (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.) |
||
Standard sensing object |
Iron, 100 × 100 × 1 mm |
||
Response time |
15 ms max. |
25 ms max. |
|
Power supply |
12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. |
100 to 220 VAC (90 to 250 VAC), 50/60 Hz |
|
Current consumption |
10 mA max. (with no load) |
--- |
|
Leakage current |
--- |
Refer to Datasheet. |
|
Control |
Switching |
NPN open collector with a maximum current of 200 mA at 30 VDC |
10 to 200 mA |
Residual |
3 V max. under a load current of 200 mA and a cable length of 2 m |
Refer to Datasheet. |
|
Indicators |
Operation indicator (red) |
||
Operation mode |
NO. Refer to Datasheet. |
||
Ambient temperature |
Operating/Storage: - 25 to 70 ° C (with no icing or condensation) |
||
Ambient humidity |
Operating/Storage: 35% to 95% (with no condensation) |
||
Temperature influence |
± 10% max. of sensing distance at 23 ° C in the temperature range of - 25 to 70 ° C |
||
Voltage influence |
± 2% max. of sensing distance within a range of ±10% of rated power supply voltage |
||
Insulation resistance |
50 M Ω min. (at 500 VDC) between current-carrying parts and case |
||
Dielectric strength |
500 VAC (50/60 Hz) for 1min between current- carrying parts and case |
2,000 VAC (50/60 Hz) for 1 min between current- carrying parts and case |
|
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||
Shock resistance |
1,000m/s2 10 times each in X, Y, and Z directions |
||
Degree of protection |
IEC IP67 |
||
Connection method |
Pre-wired Models (Standard cable length: 1 m) |
||
Weight (packed state) |
Approx. 1.4 kg |
||
Materials |
Case |
Die-cast aluminum |
|
Sensing |
Polyester |
||
Accessories |
Instruction sheet |
* Full-wave rectified power supplies with a mean output of 24 VDC ±10% are available for the TL-LP50.