IO-Link Proximity Sensor (Standard Models)
E2E-[]-IL[]
IO-Link Makes Sensor Level Information Visible and Solves the Three Major Issues at Manufacturing Sites! Standard Proximity Sensor.
DC 3-wire IO-Link Models (E2E-X[]B4-IL[])
Item |
Size |
M12 |
M18 |
M30 |
Shielded |
Shielded |
|||
Model |
E2E-X3B4-IL[] |
E2E-X7B4-IL[] |
E2E-X10B4-IL[] |
|
Sensing distance |
3 mm ±10% |
7 mm ±10% |
10 mm ±10% |
|
Set distance *1 |
0 to 2.4 mm |
0 to 5.6 mm |
0 to 8 mm |
|
Differential travel |
10% max. of sensing distance |
|||
Detectable object |
Ferrous metal |
|||
Standard sensing object |
Iron, 12 × 12 × 1 mm |
Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm |
|
Response frequency *2 |
1 kHz |
0.5 kHz |
0.4 kHz |
|
Power supply voltage |
10 to 30 VDC (including 10% ripple (p-p)) |
|||
Current consumption |
20 mA max. |
|||
Control output |
Load current |
100 mA max. |
||
Residual voltage |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
|||
Indicators *1 |
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability |
|||
Operation mode |
PNP NO/NC switching type (Factory setting: NO) |
|||
Protection circuits |
Power supply reverse polarity protection, output reverse polarity protection, surge |
|||
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) |
|||
Ambient humidity range |
Operating/Storage: 35% to 95% (with no condensation) |
|||
Temperature influence |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence |
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range |
|||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
|||
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
|||
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z |
|||
Shock resistance |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection |
IEC 60529 IP67, in-house standards: oil-resistant *3 |
|||
Connection method |
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models |
|||
Materials |
Case |
Nickel-plated brass |
||
Sensing surface |
PBT |
|||
Clamping nuts |
Nickel-plated brass |
|||
Toothed washer |
Zinc-plated iron |
|||
Main IO-Link functions |
Operation mode switching between NO and NC, self diagnosis enabling, excessive |
|||
Communication |
IO-Link |
Ver 1.1 |
||
Baud rate |
-IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps) |
|||
Data length |
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) |
|||
Minimum cycle |
-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms |
|||
Accessories |
Instruction manual |
Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).
1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.) Please contact your OMRON sales representative regarding assignment of data.
2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
3. Oil resistance in-house standard: Performance with respect to water insoluble oil.
(Test at below)
Oil resistance test
After the test time elapses, the characteristics below are checked for problems.
(1) Visual appearance (no damage that affects product characteristics)
(2) Operation check (ON/OFF) (3) Insulation resistance (50 MΩ min. at 500 VDC)
(4) Dielectric strength (500 VAC, 1 min.)
(5) Water resistance (IP67)