Slim Incremental 50-mm-dia. Rotary Encoder
E6C2-C
General-purpose Encoder with External Diameter of 50 mm
Model |
E6C2-CWZ6C |
E6C2-CWZ5B |
E6C2-CWZ3E |
E6C2-CWZ1X |
|
Power supply voltage |
5 VDC -5% to |
12 VDC -10% to |
5 VDC -5% to |
5 VDC ±5%, |
|
Current |
0.6 W max. |
0.8 W max. |
0.6 W max. |
160 mA max. |
|
Resolution |
10, 20, 30, 40, 50, 60, |
100, 200, 360, 500, |
10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, |
||
Output phases |
Phases A, B, and Z |
|
|||
Output configuration |
NPN open-collector |
PNP open-collector |
Voltage output (NPN |
Line driver output *2 |
|
Output capacity |
Applied voltage: 30 |
Applied voltage: 30 |
Output resistance: 2 |
AM26LS31 equivalent |
|
Maximum response |
100 kHz |
50 kHz |
100 kHz |
||
Phase difference |
90°±45° between A and B (1/4 T ± 1/8 T) |
||||
Rise and fall times |
1 μs max. |
1 μs max. |
0.1 μs max. |
||
Starting torque |
10 mNm max. |
||||
Moment of inertia |
1×10-6 kgm2 max.; 3 × 10-7 kgm2 max. at 600 P/R max. |
||||
Shaft |
Radial |
50 N |
|||
Thrust |
30 N |
||||
Maximum |
6,000 r/min |
||||
Protection circuits |
Power supply reverse polarity protection, Load short-circuit protection |
--- |
|||
Ambient temperature |
Operating: -10 to 70°C (with no icing), Storage: -25 to 85°C (with no icing) |
||||
Ambient humidity |
Operating/Storage: 35% to 85% (with no condensation) |
||||
Insulation resistance |
100 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance |
Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each in X, Y, |
||||
Shock resistance |
Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions |
||||
Degree of protection |
IEC 60529 IP64, in-house standards: oilproof |
||||
Connection method |
Pre-wired Models (Standard cable length: 2 m) |
||||
Material |
Case: Zinc alloy, Main unit: Aluminum, Shaft: SUS420J2 |
||||
Weight |
Approx. 400 g |
||||
Accessories |
Instruction manual |
Note: Origin Indication The following illustration shows the relationship between phase Z and the origin. Set cut face D to the phase Z origin as shown in the illustration.
1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON.
2. The line driver output is a data transmission circuit compatible with RS-422A and long-distance transmission is possible with a twisted-pair cable.(AM26LS31 equivalent)
3. The maximum electrical response speed is determined by the resolution and maximum response frequency as
follows:
This means that the E6C2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical response speed.