Compact non-contact Door Switch

D40Z

Supports ISO 13849-1 (PLe/Safety Category 4). Can be used on higher risk level applications by connecting to Safety Controllers.

List of Models
Non-contact Door Switches (Switch/Actuator)
Classification
Appearance
Auxiliary monitoring output
Cable length
Model
Standard models
Photocoupler outputs *
2 m
D40Z-1C2
5 m
D40Z-1C5
Note: Must be used in combination with a G9SP Safety Controller or a G9SX-NS[] Non-contact Door Switch Controller.
*1.
Photocoupler output. Load current: 10 mA
Controllers
Non-contact Door Switch Controller G9SX-NS[]
Safety outputs *1
Auxiliary
monitoring

output *3
Logical
AND

con-

nection
input
Logical
AND

con-

nection
output
OFF-
delayed

Max.

OFF-

delay

time

*4
Rated
voltage
Terminal
block

type
Model
Instanta-
neous
OFF-
delayed *2
2
(Semi-

conductors)
0
2
(Semi-

conductors)
1
1
--
24
VDC
Screw
terminals
G9SX-NS202-RT
Spring-
cage

terminals
G9SX-NS202-RC
2
(Semi-

conductors)
3.0 s
Screw
terminals
G9SX-NSA222-T03-RT
Spring-
cage

terminals
G9SX-NSA222-T03-RC
Note: For details, refer to the D40A/G9SX-NS Catalog (Cat. No. C140).
*1.
P channel MOS FET transistor output
*2.
The OFF-delayed output becomes an instantaneous output by setting the OFF-delay time to 0s.
*3. PNP transistor output

*4. The OFF-delay time can be set in 16 steps as follows:

      0/0.2/0.3/0.4/0.5/0.6/0.7/0.8/0.9/1.0/1.2/1.4/1.8/2.0/2.5/3.0 s
Safety Controller G9SP Series
Name
No. of I/O points
Unit version
Model
Safety
inputs
Test
outputs
Safety outputs
Standard
outputs
Safety Controller
10
4
Semiconductor outputs: 4
4
Ver.2.0
G9SP-N10S
10
6
Semiconductor outputs: 16
--
G9SP-N10D
20
6
Semiconductor outputs: 8
--
G9SP-N20S
Note: For details, refer to the G9SP Catalog (Cat. No. F090).