Small Safety Limit Switch

D4F

Ultra-Small Safety Limit Switch

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
 • Low Voltage Directive
 • EN50047
 • EN60204-1
 • EN ISO 14119
 • GS-ET-15 

Certified Standards

Certification body

Standards

File No.

TÜV SÜD

EN60947-5-1
 (certified direct opening)

*1

UL *2

UL508
 CSA C22.2 No.14

E76675

CQC (CCC) *3

GB/T14048.5

*1

1. Contact your OMRON sales representative.
 2. Certification has been obtained for CSA C22.2 No. 14 under UL.
 3. Ask your OMRON representative for information on certified models. 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T14048.5)

Item

AC-15

DC-13

Rated operating current (Ie)

0.75 A

0.27 A

Rated operating voltage (Ue)

240 V

250 V

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. 

UL/CSA (UL508, CSA C22.2 No. 14)

C300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC
 240 VAC

2.5 A

15
 7.5

1.5
 0.75

1,800

180

Q300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

125 VDC
 250 VDC

2.5 A

0.55
 0.27

0.55
 0.27

69

69

Characteristics

Degree of protection *1 

IP67 (EN60947-5-1)

Durability *2 

Mechanical 

10,000,000 times min.

Electrical 

1,000,000 times min. (4 mA resistive load at 24 VDC, 4 circuits)
 150,000 times min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24
 VDC, 2 circuits) *3

Operating speed 

1 mm/s to 0.5 m/s

Operating frequency 

Mechanical 

120 operations/minute

Electrical 

30 operations/minute

Contact resistance *5 

300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 m Ωmax. (with 5 m
 cable)

Minimum applicable load *4 

4 mA resistive load at 24 VDC, 4 circuits (N-level reference value)

Rated insulation voltage (Ui) 

250 V

Rated frequency 

50/60 Hz

Protection against electric shock 

Class I (with a ground wire)

Pollution degree (operating environment) 

3 (EN60947-5-1)

Impulse withstand
 voltage
 (EN60947-5-1) 

Between terminals
 of same polarity
 

2.5 kV

Between terminals
 of different polarity 

4 kV

Between each
 terminal and ground 

4 kV

Insulation resistance 

100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals
 of different polarities, between current-carrying metal parts and grounds, and between
 each terminal and non-current carrying metal parts

Contact gap 

2 × 2 mm min.

Vibration resistance 

Malfunction 

10 to 55 Hz, 0.75 mm single amplitude

Shock resistance 

Destruction 

1,000 m/s2 min.

Malfunction 

300 m/s2 min.

Conditional short-circuit current 

100 A (EN60947-5-1)

Conventional free air thermal current (Ith) 

2.5 A (EN60947-5-1)

Ambient operating temperature 

- 30 to 70°C (with no icing)

Ambient operating humidity 

95% max.

Cable 

UL2464 No. 22 AWG, finishing O.D.: 8.3 mm

Weight 

Approx. 190 g (D4F-102-1R, with 1 m cable)
 Approx. 220 g (D4F-120-1R, with 1 m cable)

Note: 1. The above values are initial values.
            2. Once the contact is opened or closed with an ordinary load, it cannot be used for a load smaller than that. The contact surface may be rough, which impairs the reliability of contacting.
 1. The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing performance under the actual operating environment and conditions.
 2. Durability values are calculated at an operating temperature of 5 to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.
 3. Do not apply 1 A at 125 VAC to more than two circuits.
 4. The value will vary depending on factors such as the switching frequency, the ambient environment, and the reliability level. Be sure to confirm correct operation with the actual load before application.
 5. The contact resistance was measured with 0.1 A at 5 to 8 VDC with a fall-of-potential method.