Product Category

Guard Lock Safety-door Switch/Slide key

D4JL, D4JL-SK40

Holding Force of 3,000 N

Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• EN ISO 14119

• EN 60204-1

• GS-ET-19
Certified Standards
Certification body
Standard
File No.
TÜV SÜD
EN 60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
UL *1
UL 508, CSA C22.2 No.14
E76675
CQC (CCC)
GB/T 14048.5
Consult your OMRON representative for details.
KOSHA *2
EN60947-5-1
Consult your OMRON representative for details.
*1. CSA C22.2 No. 14 was certified by UL.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN 60947-5-1)
Utilization category
AC-15
DC-13
Rated operating current (Ie)
3 A
0.27 A
Rated operating voltage (Ue)
240 V
250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
           into the Switch.
UL/CSA (UL 508, CSA C22.2 No. 14)
A300 (between terminals 12 and 41)
Rated voltage
Carry current
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
120 VAC
10 A
60
6
7,200
720
240 VAC
30
3
A300 (between all other terminals)
Rated voltage
Carry current
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
240 VAC
3 A
30
3
7,200
720
Q300
Rated voltage
Carry current
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
125 VDC
250 VDC
2.5 A
0.55
0.27
0.55
0.27
69
69
Solenoid Coil Characteristics
Type
24 VDC
Rated operating voltage (100% ED)
24 VDC +10%, -15%
Current consumption
Approx. 200 mA
Insulation Class
Class B (130°C max.)
Indicator Characteristics
Type
LED
Rated voltage
24 VDC
24 VDC
Current consumption
Approx. 1 mA
Approx. 8 mA
Color (LED)
Orange
Green
Characteristics
Interlock type
Type 2 (EN ISO 14119)
Coding level
Low level coded (EN ISO 14119)
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2
Mechanical
1,000,000 operations min.
 
Trapped key
10,000 operations min.
Rear release
button
D4JL-[][]FA-[]7-[]: 3,000 operations min.
D4JL-[][]FA-[]8-01-SJ: 500 operations min.
Electrical
500,000 operations min. (3 A resistive load at 250 VAC) *3
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *4
60 N min. (EN60947-5-1)
Direct opening travel *4
15 mm min. (EN60947-5-1)
Holding force (Fzh) *5
3,000 N min.
Contact resistance
25 max. (per contact)
Minimum applicable load *6
1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)
300 V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against electric shock
Class II (double insulation)
Pollution degree (operating environment)
3 (EN60947-5-1)
Impulse
withstand

voltage (
Uimp)
(EN60947-5-1)
Between terminals of
same polarity
2.5 kV
Between terminals of
different polarity
4 kV
Between other
terminals and

non-current carrying

metallic parts
6 kV
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact gap
2 × 2 mm min.
Vibration resistance
Malfunction
10 to 55 Hz, 0.75 mm single amplitude
Shock resistance
Destruction
1,000 m/s2 min.
Malfunction
80 m/s2 min.
Conditional short-circuit current
100 A (EN60947-5-1) *7
Conventional free air thermal current (Ith)
10 A (between terminals 12 and 41),
3 A (between all other terminals) (EN60947-5-1)
Ambient operating temperature
-10 to +55°C (with no icing)
Ambient operating humidity
95% max.
Weight
Approx. 650 g (D4JL-4NFA-C7-01)
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration,
do not use the D4JL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For further conditions, consult your OMRON sales representative.

*3. Do not pass a 3
A, 250 VAC load through more than two circuits.
*4. These figures are minimum requirements for safe operation.

*5. This figure is based on the GS-ET-19 evaluation method.

*6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.

*7. Use a 10 A fuse type
gI or gG that conforms to IEC 60269 as a short-circuit protection device.