Safety Limit Switch

D4N

Popular Safety Limit Switches Providing a Full Lineup Conforming to International Standards

\Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
 • Low Voltage Directive
 • EN50047
 • EN60204-1
 • EN ISO 14119
 • GS-ET-15 

Certified Standards

Certification body

Standards

File No.

TÜV SÜD

EN60947-5-1
 (certified direct opening)

*1

UL *2

UL508, CSA C22.2 No.14

E76675

CQC (CCC) *3

GB/T14048.5

*1

1. Consult your OMRON representative for details.
 2. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
 3. Ask your OMRON representative for information on certified models. 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T14048.5)

Item

AC-15

DC-13

Rated operating current (Ie)

3 A

0.27 A

Rated operating voltage (Ue)

240 V

250 V

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. 

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC

10 A

60

6

7,200

720

240 VAC

30

3

Q300

Rated voltage

Carry current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

125 VDC

2.5 A

0.55

0.55

69

69

250 VDC

0.27

0.27

Characteristics

Degree of protection *1

IP67 (EN60947-5-1)

Durability *2

Mechanical

15,000,000 operations min. *5

Electrical

500,000 operations min. (3 A resistive load at 250 VAC) *3
 300,000 operations min. (10 A resistive load at 250 VAC)

Operating speed

1 to 500 mm/s (D4N-1120)

Operating frequency

30 operations/minute max.

Contact resistance

25 mΩ max.

Minimum applicable load *4

1 mA resistive load at 5 VDC (N-level reference value)

Rated insulation voltage (Ui)

300 V

Rated frequency

50/60 Hz

Protection against electric shock

Class II (double insulation)

Pollution degree (operating environment)

3 (EN60947-5-1)

Impulse withstand
 voltage
 (EN60947-5-1)

Between terminals of same polarity

2.5 kV

Between terminals of different
 polarity

4 kV

Between each terminal and non-
 current carrying metallic parts

6 kV

Insulation resistance

100 MΩ min.

Contact gap

Snap-action: 2 × 0.5 mm min.
 Slow-action: 2 × 2 mm min.

Vibration resistance

Malfunction

10 to 55 Hz, 0.75 mm single amplitude

Shock resistance

Destruction

1,000 m/s2 min.

Malfunction

300 m/s2 min.

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional free air thermal current (Ith)

10 A (EN60947-5-1)

Ambient operating temperature

-30 to 70°C (with no icing)

Ambient operating humidity

95% max.

Weight

Approx. 82 g (D4N-1120)
 Approx. 99 g (D4N-6120)

Note: 1. The above values are initial values.
            2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in roughening of the contact surface and contact reliability may be lost.
 1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning may occur.
 2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.
 3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
 4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.
 5. The mechanical durability of fork lever lock models is 10,000,000 operations min.