IO-Link Proximity Sensor (Standard Models)

E2E-[]-IL[]

IO-Link Makes Sensor Level Information Visible and Solves the Three Major Issues at Manufacturing Sites! Standard Proximity Sensor.

DC 3-wire IO-Link Models (E2E-X[]B4-IL[])

Item

Size

M12

M18

M30

Shielded

Shielded

Model

E2E-X3B4-IL[]

E2E-X7B4-IL[]

E2E-X10B4-IL[]

Sensing distance

3 mm ±10%

7 mm ±10%

10 mm ±10%

Set distance *1

0 to 2.4 mm

0 to 5.6 mm

0 to 8 mm

Differential travel

10% max. of sensing distance

Detectable object

Ferrous metal
 (The sensing distance decreases with non-ferrous metal. Refer to Engineering
 Data on Catalog.)

Standard sensing object

Iron, 12 × 12 × 1 mm

Iron, 18 × 18 × 1 mm

Iron, 30 × 30 × 1 mm

Response frequency *2

1 kHz

0.5 kHz

0.4 kHz

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p))

Current consumption

20 mA max.

Control output

Load current

100 mA max.

Residual voltage

2 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators *1

In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability
 indicator (green, lit)
 In the IO-Link mode: Operation indicator (orange, lit) and communication indicator
 (green, blinking at 1 s intervals)

Operation mode

PNP NO/NC switching type (Factory setting: NO)
 Refer to the timing charts under I/O Circuit Diagrams on Catalog for details.

Protection circuits

Power supply reverse polarity protection, output reverse polarity protection, surge
 suppressor, and output short-circuit protection

Ambient temperature range

Operating/Storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67, in-house standards: oil-resistant *3

Connection method

Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
 (Standard cable length: 0.3 m)

Materials

Case

Nickel-plated brass

Sensing surface

PBT

Clamping nuts

Nickel-plated brass

Toothed washer

Zinc-plated iron

Main IO-Link functions

Operation mode switching between NO and NC, self diagnosis enabling, excessive
 proximity judgment distance selecting, timer function of the control output and
 timer time selecting, instability output (IO-Link mode) ON delay timer time selecting
 function, monitor output, operating hours read-out, and initial reset

Communication
 specifications

IO-Link
 specification

Ver 1.1

Baud rate

-IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps)

Data length

PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)

Minimum cycle
 time

-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms

Accessories

Instruction manual

Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).
 1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
 In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.) Please contact your OMRON sales representative regarding assignment of data.
 2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 3. Oil resistance in-house standard: Performance with respect to water insoluble oil.
 (Test at below) 

Oil resistance test

After the test time elapses, the characteristics below are checked for problems.
 (1) Visual appearance (no damage that affects product characteristics)
 (2) Operation check (ON/OFF) (3) Insulation resistance (50 MΩ min. at 500 VDC)
 (4) Dielectric strength (500 VAC, 1 min.)
 (5) Water resistance (IP67) 

 image