Stainless Steel Sensing Surface Amplifier Proximity Sensor
E2EC-M / -Q
Improved Durability with Stainless Steel Sensing Head
Type |
DC 3-Wire PNP Models |
DC 2-Wire Models |
DC 2-Wire Models (no polarity) |
||
Size |
8 dia. (Sensing Head) |
||||
Shielding |
Shielded |
||||
Model |
E2EC-MC2B1 |
E2EC-MC2D1 |
E2EC-QC2D1-M1GJ-T |
||
Sensing distance |
2 mm ± 15% |
2 mm ± 10% |
|||
Set distance |
0 to 1.2 mm |
0 to 1.4 mm |
|||
Differential travel |
15% max. of sensing distance |
||||
Detectable object |
Ferrous metals (The sensing distance will decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on Data Sheet.) |
||||
Standard sensing object |
Iron, 8 × 8 × 1 mm |
||||
Response frequency |
100 Hz |
||||
Power supply voltage |
12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) |
||||
Current consumption |
10 mA max. |
--- |
|||
Leakage current |
--- |
0.8 mA max. |
|||
Control |
Load current |
100 mA max. |
3 to 50 mA |
||
Residual voltage |
2 V max. (Load current: |
3 V max. (Load current: |
5 V max. (Load current: 50 mA, |
||
Indicators |
Operation indicator (yellow) |
Operation indicator (red), Setting indicator (green) |
|||
Operation mode (with |
NO (normally open) |
||||
Protection circuits |
Power supply reverse polarity |
Surge suppressor, Load short-circuit protection |
|||
Ambient temperature range |
Operating and storage: - 25 to 70 ° C (with no icing or condensation) |
||||
Ambient humidity range |
Operating and storage: 35% to 95% (with no condensation) |
||||
Temperature influence |
± 20% max. of sensing distance at 23 ° C in the temperature range of - 25 to 70 ° C |
||||
Voltage influence |
± 5% max. of sensing distance |
± 1% max. of sensing distance at the rated voltage range in the |
|||
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
||||
Dielectric strength |
1,000 VAC for 1 min between current carrying-parts and case |
||||
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance |
Destruction: 1,000 m/s2 10 times each in X, Y, Z directions |
||||
Degree of protection |
IEC IP67, In-house standards: oil-resistant (For Sensor Head only) |
||||
Connection method |
Pre-wired Connector Models (Standard cable length: 2 m) |
Connector Models (Standard cable |
|||
Weight (packed state) |
Approx. 65 g |
Approx. 95 g |
|||
Materials |
Sensor |
Case |
Stainless steel (SUS303) |
Stainless steel (SUS303) |
|
Sensing |
Stainless steel (SUS303) (0.2 mm) |
Stainless steel (SUS303) |
|||
Cable |
Polyester elastomer (TPEE) (Shielded) |
Fluoro-rubber (Shielded) |
|||
Cable |
Case |
ABS resin |
Stainless steel (SUS303) |
||
Cable |
Polyvinyl chloride (PVC) |
Fluorocarbon cable (flame-resistant) |
|||
Accessories |
Amplifier Mounting Bracket, instruction manual |
Note: Time is required for the sensing distance to stabilize after the power supply is turned ON. Confirm operation sufficiently in the actual operating environment and use the Sensor within the set distance to obtain a sufficient sensing distance.