Rectangular Proximity Sensor

E2Q6

Freely Change the Sensing Direction

Shielding

Shielded

Unshielded

Model

E2Q6-N20[]3-H

E2Q6-N30M[]3-H

Sensing distance

20 mm ±10%

30 mm ±10%

Set distance

0 to 16 mm

0 to 24 mm

Differential travel

15% max. of sensing distance

Detectable object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on Data Sheet.)

Standard sensing object

Iron, 60 × 60 × 1 mm

Iron, 90 × 90 × 1 mm

Response frequency *1

150 Hz

100 Hz

Power supply voltage
 (operating voltage range)

10 to 30 VDC, including 10% ripple (p-p)

Current consumption

20 mA max.

Control output

Load current

200 mA max.

Residual voltage

2 V max. (at 200 mA load current)

Indicators

Power indicator (green), detection indicator (yellow)

Operation mode

NO + NC (Normally open, Normally closed)

Protection circuits

Power supply reverse polarity protection, output reverse polarity protection, and load short-circuit protection

Ambient temperature range

Operating and storage: -25 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 95% (with no condensation)

Temperature influence

±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence

±2% max. of sensing distance at 24 VDC in the range of 24 VDC ±15%
 ±2% max. of sensing distance at 12 VDC in the range of 12 VDC ±15%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, at 50/60 Hz for 1 min. between current-carrying parts and case

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude in X, Y, and Z directions

Shock resistance (destruction)

300 m/s2 3 times each in six directions

Degree of protection

IEC IP67 *2

Connection method

Terminal block

Weight (packed state/Sensor only)

Approx. 250 g/approx. 230 g

Materials

Case

Polyamide (PA)

Sensing surface

Polyamide (PA)

Terminal base

Polyamide (PA)

Accessories

Instruction manual

1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
 2. When the recommended cable gland is used.