E3AS-HL

Sensing method

Triangulation

Model

NPN Output

E3AS-HL500MN

E3AS-HL500LMN

E3AS-HL150MN

E3AS-HL150LMN

PNP Output/COM3

E3AS-HL500MT

E3AS-HL500LMT

E3AS-HL150MT

E3AS-HL150LMT

Sensing distance *1

35 mm to the set distance

35 mm to the set distance

Setting range *1

35 to 500 mm

35 to 150 mm

Standard detectable difference
 *1

35 to 180 mm: 9 mm
 180 to 300 mm: 18 mm
 300 to 400 mm: 30 mm
 400 to 500 mm: 45 mm
 at 10 m sec

35 to 50 mm: 1 mm
 50 to 100 mm: 2 mm
 100 to 150 mm: 4 mm
 at 10 m sec

Display minimum unit value

1 mm

0.1 mm

Spot size (reference value) *2

2.5 mm × 1.5 mm
 at distance of 500
 mm

18 mm × 1.5 mm
 at distance of 500
 mm

2.5 mm × 1.3 mm
 at distance of 150
 mm

8 mm × 1.3 mm
 at distance of 150
 mm

Light source (wavelength)

Red laser (660 nm), Class1 (IEC/EN60825-1:2014)

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class2

Current consumption

100 mA max.

Input/
 output

Control output

Load power supply voltage 30 VDC max. (Class2), the total load current of the two
 outputs is 100 mA max.
 Residual voltage (Load current 10 mA max.: 1 VDC max., Load current 10 to 100
 mA: 2 VDC max.)
 Open-collector output (NPN/PNP output depending on model)
 N.O. (Normally Open) / N.C. (Normally Close) selectable


NPN

OUTPUT 1: NO (Normally open), OUTPUT 2: NC (Normally closed)

PNP/COM3

OUTPUT 1: NO (Normally open)/COM[], OUTPUT 2: NC (Normally closed)

External input

Laser OFF / Teaching / Zero reset selectable
 NPN ON time: 0 V short-circuit or 1.5 V or less, OFF time: Power supply voltage
 short-circuit or open
 PNP ON time: Power supply voltage short-circuit or within power supply voltage
 - 1.5 V, OFF time: 0 V short-circuit or open

Response time

1.5 ms / 10 ms / 50 ms selectable

Threshold setting method

Teaching method / Manual Operations / IO-Link communications

Mutual interference prevention

4 units max. (when using the mutual interference prevention function)

Ambient illumination

Receiver surface illuminance:
 Incandescent lamp: 20,000 lx max.,
 Sunlight: 25,000 lx max. at distance of
 250 mm
 Incandescent lamp: 5,000 lx max.,
 Sunlight: 10,000 lx max. at distance of
 500 mm

Receiver surface illuminance:
 Incandescent lamp: 8,000 lx max.,
 Sunlight: 16,000 lx max.

1. Measured with OMRON's standard workpiece (White ceramic).
 2. Defined by D4σ method at the maximum sensing distance. Detection may be influenced if there is light leakage outside
       the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
       Also, when detecting a workpiece that is smaller than the spot size, a correct value may not be obtained.

E3AS-F

Sensing method

TOF (Time of flight)

Model

Type

Metal case ([]: M), Plastic case ([]: P)

NPN output

E3AS-F1500I[]N

E3AS-F1000I[]N

PNP output/ COM3

E3AS-F1500I[]T

E3AS-F1000I[]T

Sensing distance

50 mm to the set distance
 (White paper or black paper 200 × 200
 mm)

50 mm to the set distance
 (White paper or black paper 200 × 200
 mm)

Setting range

100 to 1,500 mm (White paper 200 ×
 200 mm)
 100 to 1,000 mm (Black paper 200 × 200
 mm)

100 to 1,000 mm (White paper 200 ×
 200 mm)
 100 to 500 mm (Black paper 200 × 200
 mm)

Spot diameter (reference value)

95 mm dia. (at distance of 1,000 mm)

Differential travel

15% max. of set distance (Set distance 200 mm min.)

Reflectivity characteristic
 (black/white error)

10% max. of set distance (Set distance 200 mm min.)

Light source (wavelength)

Infrared laser (940 nm) Class1 (IEC/EN60825-1:2014)

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class2

Current consumption

30 mA max.

Input/
 output

Control output

Load power supply voltage: 30 VDC max., Class2, Load current: 100 mA max.
 (Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to
 100 mA: 2 V max.)
 Open-collector output (NPN/PNP output depending on model)


NPN

OUTPUT 1: NO (Normally open), OUTPUT 2: NC (Normally closed)

PNP/COM3

OUTPUT 1: NO (Normally open)/COM[], OUTPUT 2: NC (Normally closed)

Response time

Operate or reset: 150 ms max.

Operate or reset: 90 ms max.

Threshold setting method

Teaching method/IO-Link communications

Ambient illumination

Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.

E3AS-L

Sensing method

Triangulation

Model

NPN Output

E3AS-L200MN

E3AS-L80MN

PNP Output/COM3

E3AS-L200MT

E3AS-L80MT

Sensing distance

10 mm to the set distance (White paper or black paper 100 × 100 mm)

Setting range

40 to 200 mm (White paper or black
 paper 100 × 100 mm)

20 to 80 mm (White paper or black
 paper 100 × 100 mm)

Spot diameter (reference value)

25 × 25 mm at distance of 200 mm

4 mm dia. (at distance of 80 mm)

Differential travel

10% max. of set distance

White paper: 2% max. of set distance
 Black paper: 5% max. of set distance

Reflectivity characteristic
 (black/white error)

10% max. of set distance

5% max. of set distance

Light source (wavelength)

Red LED (624 nm)

Red LED (650 nm)

Power supply voltage

10 to 30 VDC (including 10% ripple (p-p)), Class2

Current consumption

35 mA max.

Input/
 output

Control output

Load power supply voltage: 30 VDC max., Class2, Load current: 100 mA max.
 (Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to
 100 mA: 2 V max.)
 Open-collector output (NPN/PNP output depending on model)


NPN

OUTPUT 1: NO (Normally open), OUTPUT 2: NC (Normally closed)

PNP/COM3

OUTPUT 1: NO (Normally open)/COM[], OUTPUT 2: NC (Normally closed)

Response time

Operate or reset: 1 ms max.

Threshold setting method

Teaching method/IO-Link communications

Ambient illumination

Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.

Common to E3AS series

Series

E3AS-HL

E3AS-F

E3AS-L

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and
 Output reverse polarity protection

Ambient temperature range

Operating: -10 to 50°C,
 Storage: -25 to 70°C
 (with no icing or
 condensation)

Operating: -20 to 55°C,
 Storage: -40 to 70°C
 (with no icing or
 condensation)

Operating: -25 to 55°C,
 Storage: -40 to 70°C
 (with no icing or
 condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Vibration resistance

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
 directions

Shock resistance

500 m/s2 for 3 times each in X, Y, and Z directions

Degree of protection

IP67 (IEC60529) and IP67G *1 (JIS C 0920 Annex 1), IP69K (ISO20653)

Indicators

OLED Display (White),
 Power/Communication
 indicator (Green*),
 Operation indicator
 (Orange)
 * IO-Link Communication
 mode: blinking

Operation indicator (orange), Stability & Communication
 indicator (green*)
 * IO-Link Communication mode: blinking

Connection method

Pre-wired (standard cable length: 2 m), M8 Connector, M12 Pre-wired Smartclick
 Connector (standard cable length: 0.3m)

Weight
 (packed state/
 Sensor only)

Pre-wired
 (2 m)

Approx. 180 g/
 approx. 110 g

Metal case type:
 Approx. 135 g/approx. 90 g
 Plastic case type:
 Approx. 115 g/approx. 70 g

Approx. 135 g/
 approx. 90 g

M8 Connector

Approx. 120 g/
 approx. 50 g

Metal case type:
 Approx. 75 g/approx. 30 g
 Plastic case type:
 Approx. 60 g/approx. 15 g

Approx. 75 g/
 approx. 30 g

M12 Pre-wired
 Smartclick
 Connector
 (0.3m)

Approx. 150 g/
 approx. 80 g

Metal case type:
 Approx. 95 g/approx. 50 g
 Plastic case type:
 Approx. 75 g/approx. 30 g

Approx. 95 g/
 approx. 50 g

Materials

Case

Stainless steel
 (SUS316L)

Metal case type:
 Main unit/mounting part/
 connector part
 Stainless steel (SUS316L)
 Plastic case type: Main unit
 Polybutylene terephthalate
 (PBT) /polycarbonate (PC),
 Mounting part/connector part
 Nickel-plated brass

Stainless steel
 (SUS316L)

Lens cover
 and Display

Methacrylic resin (PMMA) (Lens cover: Antifouling coating)

Indicator

Polyamide 11 (PA11)

Metal case type:
 Polyamide 11 (PA11)
 Plastic case type:
 Polyethersulfone (PES)

Polyamide 11 (PA11)

Main IO-Link functions

Operation mode switching between NO and NC, execution of teaching (2-point
 teaching, Background teaching), setup of the threshold, timer function of the control
 output and timer time selecting, Restore Factory Settings, Key Lock (Unlock, Lock,
 Lock (No Button)), monitor output* (Detection level, Incident light level) * Only for
 E3AS-HL and E3AS-F

IO-Link
 Communication
 specifications

IO-Link
 specification

Ver. 1.1

Baud rate

COM3 (230.4 kbps)

Data length

PD size: 4 bytes, OD size: 1 byte (M-sequence type:
 TYPE_2_V)

PD size: 1 byte,
 OD size: 1 byte
 (M-sequence type:
 TYPE_2_1)

Minimum cycle
 time

COM3: 1.2 ms

Accessories

Instruction manual, compliance sheet, index list (attached for IO-Link type only)
 E3AS-HL: FDA certification label and Warning label
 E3AS-F: FDA certification label
 Note: Mounting Brackets must be ordered separately.

*1. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
       The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance
       to oil.