Straight type (E3FA/E3FB)

Sensing method

Through-beam

Retro-reflective
 with
 MSR function

Coaxial Retro-
 reflective with
 MSR function

Model

NPN
 output

Pre-wired

E3F[]-TN11 2M

E3FA-TN12 2M

E3F[]-RN11 2M

E3F[]-RN12 2M

M12
 Connector

E3F[]-TN21

E3FA-TN22

E3F[]-RN21

E3F[]-RN22

PNP
 output

Pre-wired

E3F[]-TP11 2M

E3FA-TP12 2M

E3F[]-RP11 2M

E3F[]-RP12 2M

M12
 Connector

E3F[]-TP21

E3FA-TP22

E3F[]-RP21

E3F[]-RP22

Sensing distance

20 m

15 m

0.1 to 4 m
 (with E39-R1S)

0 to 500 mm
 (with E39-R1S)

Spot diameter (reference
 value)

Standard sensing object

Opaque: 7 mm dia.min.

Opaque: 75 mm dia.min.

Differential travel

Directional angle

2° min.

Light source (wavelength)

Red LED (624 nm)

Infrared LED
 (850 nm)

Red LED (624 nm)

Power supply voltage

10 to 30 VDC (include voltage ripple of 10%(p-p) max.)

Current consumption

40 mA max.
 (Emitter 25 mA max. Receiver 15 mA max.)

25 mA max.

Control output

NPN/PNP (open collector)
 Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage:
 30 VDC max.

Operation mode

Light-ON/Dark-ON selectable by wiring

Indicator

Operation indicator (orange)
 Stability indicator (green)
 Power indicator (green): only Emitter of Through-beam

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and
 Output reverse polarity protection

Response time

0.5 ms

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max.

Ambient temperature range

Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35 to 85%/Storage: 35 to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
 directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y and Z directions

Degree of protection

IEC: IP67, DIN 40050-9: IP69K *

Weight
 (packed
 state/
 only
 sensor)

Pre-wired cable
 (2M)

E3FA: Approx. 110 g/Approx. 50 g,
 respectively,
 E3FB: Approx. 175 g/Approx. 65 g,
 respectively

E3FA: Approx. 60 g/Approx. 50 g,
 E3FB: Approx. 95 g/Approx. 65 g

Connector

E3FA: Approx. 30 g/Approx. 10 g,
 respectively,
 E3FB: Approx. 85 g/Approx. 20 g,
 respectively

E3FA: Approx. 20 g/Approx. 10 g,
 E3FB: Approx. 50 g/Approx. 20 g

Material

Case

E3FA: ABS, E3FB: Nickel-brass

Lens and Display

PMMA

Adjuster

POM

Nut

E3FA: POM, E3FB: Nickel-brass

Accessories

Instruction sheet
 M18 nuts (4 pcs)

Instruction sheet
 M18 nuts (2 pcs)

 

* IP69K Degree of Protection Specifications
 IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
 The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
 The distance between the test item and the nozzle is 10 to 

15

 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally

 image

Sensing method

Diffuse-reflective

Model

NPN
 output

Pre-wired

E3F[]-
 DN11 2M

E3F[]-
 DN12 2M

E3F[]-
 DN13 2M

E3FA-
 DN14 2M

E3FA-
 DN15 2M

E3FA-
 DN16 2M

M12
 Connector

E3F[]-
 DN21

E3F[]-
 DN22

E3F[]-
 DN23

E3FA-
 DN24

E3FA-
 DN25

E3FA-
 DN26

PNP
 output

Pre-wired

E3F[]-
 DP11 2M

E3F[]-
 DP12 2M

E3F[]-
 DP13 2M

E3FA-
 DP14 2M

E3FA-
 DP15 2M

E3FA-
 DP16 2M

M12
 Connector

E3F[]-
 DP21

E3F[]-
 DP22

E3F[]-
 DP23

E3FA-
 DP24

E3FA-
 DP25

E3FA-
 DP26

Sensing distance

100 mm
 (white paper:
 300 × 300
 mm)

300 mm
 (white paper:
 300 × 300
 mm)

1 m
 (white paper:
 300 × 300
 mm)

100 mm
 white paper:
 300 × 300
 mm)

300 mm
 (white paper:
 300 × 300
 mm)

1 m
 (white paper:
 300 × 300
 mm)

Spot diameter
 (reference value)

40 × 45 mm
 Sensing
 distance of
 100 mm

40 × 50 mm
 Sensing
 distance of
 300 mm

120 × 150
 mm
 Sensing
 distance of
 1 m

40 × 45 mm
 Sensing
 distance of
 100 mm

40 × 50 mm
 Sensing
 distance of
 300 mm

120 × 150
 mm
 Sensing
 distance of
 1 m

Standard sensing object

--

Differential travel

20% max.

Directional angle

--

Light source (wavelength)

Red LED (624 nm)

Infrared LED (850 nm)

Power supply voltage

10 to 30 VDC (include voltage ripple of 10%(p-p) max.)

Current consumption

25 mA max.

Control output

NPN/PNP (open collector)
 Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30
 VDC max.

Operation mode

Light-ON/Dark-ON selectable by wiring

Indicator

Operation indicator (orange)
 Stability indicator (green)

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and Output
 reverse polarity protection

Response time

0.5 ms

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max.

Ambient temperature range

Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35 to 85%/Storage: 35 to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
 directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y and Z directions

Degree of protection

IEC: IP67, DIN 40050-9: IP69K *

Weight
 (packed
 state/
 only
 sensor)

Pre-wired cable
 (2M)

E3FA: Approx. 60 g/Approx. 50 g,
 E3FB: Approx. 95 g/Approx. 65 g

Connector

E3FA: Approx. 20 g/Approx. 10 g,
 E3FB: Approx. 50 g/Approx. 20 g

Material

Case

E3FA: ABS, E3FB: Nickel-brass

Lens and Display

PMMA

Adjuster

POM

Nut

E3FA: POM, E3FB: Nickel-brass

Accessories

Instruction sheet
 M18 nuts (2 pcs)

 

* IP69K Degree of Protection Specifications
 IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
 The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
 The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally. 

 

image

Sensing method

BGS
 (Background suppression)

Limited
 distance
 reflective

Transparent detected with
 P-opaquing function

Model

NPN
 output

Pre-wired

E3F[]-LN11
 2M

E3F[]-LN12
 2M

E3F[]-VN11
 2M

E3F[]-BN11
 2M

E3F[]-BN12
 2M

M12
 Connector

E3F[]-LN21

E3F[]-LN22

E3F[]-VN21

E3F[]-BN21

E3F[]-BN22

PNP
 output

Pre-wired

E3F[]-LP11
 2M

E3F[]-LP12
 2M

E3F[]-VP11
 2M

E3F[]-BP11
 2M

E3F[]-BP12
 2M

M12
 Connector

E3F[]-LP21

E3F[]-LP22

E3F[]-VP21

E3F[]-BP21

E3F[]-BP22

Sensing distance

100 mm
 (white paper:
 300 × 300 mm)

200 mm
 (white paper:
 300 × 300 mm)

10 to 50 mm
 (glass (t = 1.0
 mm): 150 ×
 150 mm)

100 to 500 mm
 (with E39-RP1)

0.1 to 2 m
 (with E39-RP1)

Spot diameter
 (reference value)

10 × 10 mm
 Sensing
 distance of
 100 mm

10 × 15 mm
 Sensing
 distance of
 200 mm

10 × 10 mm
 Sensing
 distance of
 50 mm

--

Standard sensing object

--

glass(t = 1.0 mm): 150 × 150 mm

Differential travel

20% max.

--

Directional angle

--

Light source (wavelength)

Red LED (624 nm)

Power supply voltage

10 to 30 VDC (include voltage ripple of 10%(p-p) max.)

Current consumption

25 mA max.

Control output

NPN/PNP (open collector)
 Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30
 VDC max.

Operation mode

Light-ON/Dark-ON selectable by wiring

Indicator

Operation indicator (orange)
 Stability indicator (green)
 Power indicator (green): only Emitter of Through-beam

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and Output
 reverse polarity protection

Response time

0.5 ms

Sensitivity adjustment

Fixed

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max.

Ambient temperature range

Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35 to 85%/Storage: 35 to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
 directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y and Z directions

Degree of protection

IEC: IP67, DIN 40050-9: IP69K *

Weight
 (packed
 state/
 only
 sensor)

Pre-wired cable
 (2M)

E3FA: Approx. 60 g/Approx. 50 g,
 E3FB: Approx. 95 g/Approx. 65 g

Connector

E3FA: Approx. 20 g/Approx. 10 g,
 E3FB: Approx. 50 g/Approx. 20 g

Material

Case

E3FA: ABS, E3FB: Nickel-brass

Lens and Display

PMMA

Adjuster

POM

Nut

E3FA: POM, E3FB: Nickel-brass

Accessories

Instruction sheet
 M18 nuts (2 pcs)

 

* IP69K Degree of Protection Specifications
 IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
 The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
 The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally. 

 

image

Radial type (E3RA/E3RB)

Sensing method

Through-
 beam

Retro-
 reflective
 with MSR
 function

Diffuse-reflective

Model

NPN
 output

Pre-wired

E3R[]-TN11
 2M

E3R[]-RN11
 2M

E3R[]-DN11
 2M

E3R[]-DN12
 2M

E3R[]-DN13
 2M

M12
 Connector

E3R[]-TN21

E3R[]-RN21

E3R[]-DN21

E3R[]-DN22

E3R[]-DN23

PNP
 output

Pre-wired

E3R[]-TP11
 2M

E3R[]-RP11
 2M

E3R[]-DP11
 2M

E3R[]-DP12
 2M

E3R[]-DP13
 2M

M12
 Connector

E3R[]-TP21

E3R[]-RP21

E3R[]-DP21

E3R[]-DP22

E3R[]-DP23

Sensing distance

15 m

0.1 to 3 m
 (with E39-R1S)

100 mm
 (white paper:
 300 × 300 mm)

300 mm
 (white paper:
 300 × 300 mm)

700 mm
 (white paper:
 300 × 300 mm)

Spot diameter
 (reference value)

--

35 × 40 mm
 Sensing
 distance of
 100 mm

40 × 45 mm
 Sensing
 distance of
 300 mm

90 × 120 mm
 Sensing
 distance of
 700 mm

Standard sensing object

Opaque:
 7 mm dia. min.

Opaque:
 75 mm dia. min.

--

Differential travel

--

20% max.

Directional angle

2° min.

--

Light source (wavelength)

Red LED (624 nm)

Power supply voltage

10 to 30 VDC (include voltage ripple of 10%(p-p) max.)

Current consumption

40mA max.
 (Emitter 25 mA
 max. Receiver
 15 mA max.)

25 mA max.

Control output

NPN/PNP (open collector)
 Load current: 100 mA max. (Residual voltage: 2 V max.), Load power supply voltage: 30
 VDC max.

Operation mode

Light-ON/Dark-ON selectable by wiring

Indicator

Operation indicator (orange)
 Stability indicator (green)
 Power indicator (green): only Emitter of Through-beam

Protection circuits

Power supply reverse polarity protection, Output short-circuit protection, and Output
 reverse polarity protection

Response time

0.5 ms

Sensitivity adjustment

One-turn adjuster

Ambient illumination
 (Receiver side)

Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max.

Ambient temperature range

Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35 to 85%/Storage: 35 to 95% (with no condensation)

Insulation resistance

20 MΩ min. at 500 VDC

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
 directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y and Z directions

Degree of protection

IEC: IP67, DIN 40050-9: IP69K *

Weight
 (packed
 state/
 only
 sensor)

Pre-wired cable
 (2M)

E3RA:
 Approx. 110 g/
 Approx. 50 g,
 respectively,
 E3RB:
 Approx. 175 g/
 Approx. 65 g,
 respectively

E3RA: Approx. 60 g/Approx. 50 g,
 E3RB: Approx. 95 g/Approx. 65 g

Connector

E3RA:
 Approx. 30 g/
 Approx. 10 g,
 respectively,
 E3RB:
 Approx. 85 g/
 Approx. 20 g,
 respectively

E3RA: Approx. 20 g/Approx. 10 g,
 E3RB: Approx. 50 g/Approx. 20 g

Material

Case

E3RA: ABS, E3RB: Nickel-brass

Lens and Display

PMMA

Adjuster

POM

Nut

E3RA: POM, E3RB: Nickel-brass

Accessories

Instruction
 sheet
 M18 nuts (4
 pcs)

Instruction sheet
 M18 nuts (2 pcs)

 

* IP69K Degree of Protection Specifications
 IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
 The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
 The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally. 

 

image