Compact Photoelectric Sensor with Built-in Amplifier
The Standard for Photoelectric Sensors with a Secure Track Record of One Million Sold Yearly.
Sensing method |
Through-beam |
Retro- |
Diffuse-reflective |
(Narrow- |
|||||||||
Model |
NPN |
Pre-wired |
E3Z-T61 |
E3Z-T62 |
E3Z-T61A |
E3Z-R61 |
E3Z-D61 |
E3Z-D62 |
E3Z-L61 |
||||
Connector |
E3Z-T66 |
E3Z-T67 |
E3Z-T66A |
E3Z-R66 |
E3Z-D66 |
E3Z-D67 |
E3Z-L66 |
||||||
PNP |
Pre-wired |
E3Z-T81 |
E3Z-T82 |
E3Z-T81A |
E3Z-R81 |
E3Z-D81 |
E3Z-D82 |
E3Z-L81 |
|||||
Connector |
E3Z-T86 |
E3Z-T87 |
E3Z-T86A |
E3Z-R86 |
E3Z-D86 |
E3Z-D87 |
E3Z-L86 |
||||||
Sensing distance |
15 m |
30 m |
10 m |
4 m (100 |
100 mm |
1 m |
90 + 30 mm |
||||||
Spot diameter |
--- |
(2.5 dia. And |
|||||||||||
Standard sensing object |
Opaque: 12-mm dia. min. |
Opaque: |
--- |
||||||||||
Minimum detectable object |
--- |
0.1 mm |
|||||||||||
Differential travel |
--- |
20% max. of setting |
Refer to |
||||||||||
Directional angle |
Both emitter and receiver: |
2 to 10° |
--- |
||||||||||
Light source (wavelength) |
Infrared LED |
Red LED |
Red LED |
Infrared LED |
Red LED |
||||||||
Current consumption |
35 mA max. (Emitter: 15 mA |
30 mA max. |
|||||||||||
Protection circuits |
Reversed power supply polarity |
Reversed power supply polarity protection, Output |
|||||||||||
Response time |
Operate |
Operate |
Operate or reset: 1 ms max. |
||||||||||
Degree of protection |
IEC, IP67 |
||||||||||||
Connection method |
Pre-wired cable (standard length: 2 m and 0.5 m), Connector (M8) |
||||||||||||
Weight |
Pre-wired cable |
Approx. 120 g |
Approx. 65 g |
||||||||||
Connector |
Approx. 30 g |
Approx. 20 g |
|||||||||||
Material |
Case |
PBT (polybutylene terephthalate) |
|||||||||||
Lens |
Modified polyarylate |
Methacrylic |
Modified polyarylate |
||||||||||
Sensing method |
Retro-reflective for clear, plastic bottles (without MSR function) |
||||||||||||
Model |
NPN output |
E3Z-B61 |
E3Z-B66 |
E3Z-B62 |
E3Z-B67 |
||||||||
PNP output |
E3Z-B81 |
E3Z-B86 |
E3Z-B82 |
E3Z-B87 |
|||||||||
Sensing distance |
500 mm (80 mm) *1 (using E39-R1S) |
2 m (500 mm) *1 *2 (using E39-R1S) |
|||||||||||
Standard sensing object |
Opaque materials, 75mm dia. min. |
||||||||||||
Light source (wavelength) |
Red LED (660 nm) |
||||||||||||
Current consumption |
30 mA max. |
||||||||||||
Protection circuits |
Reversed power supply polarity protection, Output short-circuit protection, |
||||||||||||
Response time |
Operate or reset: 1 ms max. |
||||||||||||
Degree of protection |
IEC, IP67 |
||||||||||||
Connection method |
Pre-wired cable |
Connector |
Pre-wired cable |
Connector |
|||||||||
Weight |
Pre-wired cable (2 m) |
Approx. 65 g |
|||||||||||
Standard Connector |
Approx. 20 g |
||||||||||||
Material |
Case |
PBT (polybutylene terephthalate) |
|||||||||||
Lens |
Modified polyarylate |
||||||||||||
Sensing method |
Transparent glass Limited-reflective |
||
Model |
NPN output |
E3Z-L63 |
E3Z-L68 |
PNP output |
E3Z-L83 |
E3Z-L88 |
|
Sensing distance |
30±20 mm (transparent glasses 100 × 100 mm) |
||
Spot diameter (reference value) |
2-mm dia. min. (at sensing distance of 30 mm) |
||
Minimum detectable object |
0.1 mm dia. (copper wire) |
||
Light source (wavelength) |
Red LED (660 nm) |
||
Current consumption |
30 mA max. |
||
Protection circuits |
Power supply reverse polarity protection, Output short-circuit protection, |
||
Response time |
Operate or reset: 1 ms max. |
||
Degree of protection |
IEC, IP67 |
||
Connection method |
Pre-wired (standard length: 2 m) |
M8 connector |
|
Weight |
Pre-wired cable (2 m) |
Approx. 65 g |
|
Standard Connector |
Approx. 20 g |
||
Material |
Case |
PBT (polybutylene terephthalate) |
|
Lens |
Modified polyarylate |
Oil-resistant
Sensing method |
Through-beam |
Retro-reflective |
Diffuse-reflective |
|||
Model |
NPN |
Pre-wired |
E3Z-T61K |
E3Z-R61K |
E3Z-D61K |
E3Z-D62K |
M8 Pre-wired |
E3Z-T61K-M3J |
E3Z-R61K-M3J |
E3Z-D61K- |
E3Z-D62K- |
||
PNP |
Pre-wired |
E3Z-T81K |
E3Z-R81K |
E3Z-D81K |
E3Z-D82K |
|
M8 Pre-wired |
E3Z-T81K-M3J |
E3Z-R81K-M3J |
E3Z-D81K- |
E3Z-D82K- |
||
Sensing distance |
15 m |
3 m (150 mm) * |
100 mm |
1 m |
||
Standard sensing object |
Opaque: 12-mm dia. min. |
Opaque: |
--- |
|||
Differential travel |
--- |
20% max. of setting distance |
||||
Directional angle |
Both emitter and receiver: |
2 to 10 ° |
--- |
|||
Light source (wavelength) |
Infrared LED (870 nm) |
Red LED (660 nm) |
Infrared LED (860 nm) |
|||
Current consumption |
35 mA max. (Emitter: 15 mA |
30 mA max. |
||||
Protection circuits |
Reversed power supply |
Reversed power supply polarity protection, Output |
||||
Response time |
Operate or reset: 1 ms max. |
|||||
Degree of protection |
IP67 (IEC), Oil resistant models: IP67 (IEC) (in-house standards: oilproof), |
|||||
Connection method |
Pre-wired cable (standard length: 2 m), M8 Pre-wired Connector |
|||||
Weight |
Pre-wired cable (2 m) |
Approx. 120 g |
Approx. 65 g |
|||
Connector (M8, 4 pins) |
Approx. 50 g |
Approx. 30 g |
||||
Material |
Case |
PBT (polybutylene terephthalate) |
||||
Lens |
Modified polyarylate |
Methacrylic resin |
Modified polyarylate |
* Values in parentheses indicate the minimum required distance between the Sensor and Reflector.
Common
Power supply voltage |
12 to 24 VDC±10%, ripple (p-p): 10% max. |
Control output |
Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. |
Sensitivity adjustment |
One-turn adjuster |
Ambient illumination |
Incandescent lamp: 3,000 lx max. |
Ambient temperature |
Operating: -25 to 55°C, Some connector models: -40°C to 55°C * (with no icing or |
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) |
Insulation resistance |
20 MΩ min. at 500 VDC |
Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z |
Shock resistance |
Destruction: 500 m/s2 3 times each in X, Y, and Z directions |
Indicator |
Operation indicator (orange) |
Accessories |
Instruction manual (Neither Reflectors nor Mounting Brackets are provided with any of |
* The ambient temperature range during operation for connector models depends on the model. For the E3Z-T66/T86/
R66/R86, the range is −40°C to 55°C. For the E3Z-D66/D86/D67/D87, the range is −30°C to 55°C. For other connector
models, the range is −25°C to −55°C.
The sensing distance for Retro-reflective Models (E3Z-R66/R86) between −40°C to −25°C, however, will be as follows
(not the values in the table): With E39-R1S: 3 m (100 mm), With E39-R1: 2 m (100 mm).
Also, use the XS3F-M42[]-4[][]-L Sensor I/O Connector (PUR cable) for applications between −25°C to −40°C. (Refer
to Catalog.)