Inductive Coupler

F92A

Transmit Limit Switch ON/OFF Signals without Making Contact

Model

F92A-C-1

Transmission distance

5 mm (Refer to Safety Precautions on Data Sheet.)

Set transmission distance

0 to 4.5 mm

Response time

1 ms max.

Ambient temperature

Operating/Storage: -25 to 70°C (with no icing and condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Insulation resistance

50 MΩ min. (at 500 VDC) between lead wires and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between lead wires and case

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection

IEC IP67, in-house standard for oil resistance

Connection method

Pre-wired Models (Standard cable length: 2 m)

Transmittable Proximity Sensors

E2E-X5Y1, -X5Y2
 E2E2-X5Y1, -X5Y2
 E2F-X5E1, -X5E2, -X5F1, -X5F2, -X5Y1, -X5Y2

Weight (packed state)

Approx. 160 g

Materials

Case

Brass

Sensing surface

ABS