Flow measurement
Endress+Hauser Flow measurement is one of the world’s leading providers of measuring instruments and complete systems for Flow measurement.
Products List
Proline t-mass I 500 thermal mass flowmeter
Insertion flowmeter with long-term stability as remote version with up to 4 I/Os
Predecessor: t-mass 65I
- Max. measurement error: Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
- Measuring range: 20 to 733501 kg/h (44 to 1669340 lb/h)
- Medium temperature range: -40 °C to +180°C (-40 °F to +356°F)
- Max. process pressure: -0.5 to 20 bar_g (-7.25 to 290 psi_g)
- Wetted materials: Materials for insertion tube, Stainless steel, 1.4404 (316/316L), Process connections, process coupling, Stainless steel, 1.4404 (316/316L), Sensing element, Unidirectional, Stainless steel, 1.4404 (316/316L), Alloy C22, 2.4602 (UNS N06022);, Bidirectional, Stainless steel, 1.4404 (316/316L), Reverse flow detection, Stainless steel, 1.4404 (316/316L), Clamping rings, PEEK, PVDF, 1.4404 (316/316L), Flat ring seal, EPDM, FKM
Proline t-mass T 150 thermal mass flowmeter
The flowmeter for reliable and easy monitoring of liquids
Predecessor: t-trend ATT12
- Max. measurement error: Flow: ±5 % o.f.s.
- Measuring range: 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) (under reference conditions)
- Medium temperature range: –20 to +100 °C (–4 to +212 °F)
- Max. process pressure: PN 40
- Wetted materials: Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022), Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022), Connection:, ‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022), ‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022), ‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022), ‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)
Proline Prowirl D 200 vortex flowmeter
Cost-effective wafer flowmeter, available as compact or remote version
Predecessor: Proline Prowirl D 200 / 7D2B
- Max. measurement error: Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 % - Measuring range: Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) - Medium temperature range: Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) - Max. process pressure: PN 40, Class 300, 20K
- Wetted materials: Measuring tube: 1.4408 (CF3M), DSC sensor: 1.4435 (316/316L)
Proline Prowirl O 200 vortex flowmeter
Flowmeter optimized for requirements of high-pressure mating pipes
Predecessor: Proline Prowirl O 200 / 7O2B, Proline Prowirl C 200 Only available for North Ame 7C2B
- Max. measurement error: Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85% - Measuring range: Liquid: 0.1 to 1700 m³/h (0.061 to 1000 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.52 to 22000 m³/h (0.31 to 13000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) - Medium temperature range: Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) - Max. process pressure: PN 250, Class 1500, 40K
- Wetted materials: Measuring tube: 1.4408 (CF3M), DSC sensor: UNS N07718 similar to Alloy 718, 2.4668, Process connection: 1.4404/F316/F316L
Proline Prowirl R 200 vortex flowmeter
Flowmeter with best-in-class accuracy despite pipe reduction
Predecessor: Proline Prowirl R 200 / 7R2B
- Max. measurement error: Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85% - Measuring range: Liquid: 0.1 to 540 m³/h (0.061 to 320 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.52 to 7300 m³/h (0.31 to 4300 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) - Medium temperature range: Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) - Max. process pressure: PN 40, Class 300, 20K
- Wetted materials: Measuring tube: 1.4408 (CF3M), DSC sensor: 1.4404/F316/F316L, Process connection: 1.4404/F316/F316L
Proline Promass A 100 Coriolis flowmeter
The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter
Predecessor: Promass 80A
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ - Measuring range0 to 450 kg/h (0 to 16.5 lb/min)
- Medium temperature range: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 40, Class 300, 20K, 400 bar (5800 psi)
- Wetted materials: Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022), Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Proline Promass A 200 Coriolis flowmeter
Genuine loop-powered flowmeter for accurate measurement of lowest flow rates
Predecessor: Promass 80A, Promass 83A, Proline Promass A 300 / 8A3B
- Max. measurement errorMass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 450 kg/h (0 to 16.54 lb/min)
- Medium temperature range: -50 to 205 °C (-58 to 401 °F)
- Max. process pressure: 430.9 bar (6250 psi)
- Wetted materials: Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Proline Promass A 300 Coriolis flowmeter
Accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter
Predecessor: Promass 80A, Promass 84A, Promass 83A, Proline Promass A 300 / 8A3B
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 450 kg/h (0 to 16.54 lb/min)
- Medium temperature range: -50 to 205 °C (-58 to 401 °F)
- Max. process pressure: 430.9 bar (6250 psi)
- Wetted materials: Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Proline Promass A 500 Coriolis flowmeter
Accurate single-tube flowmeter for lowest flow rates, as remote version with up to 4 I/Os
Predecessor: Promass 80A, Promass 84A, Promass 83A, Proline Promass A 500 / 8A5B
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 450 kg/h (0 to 16.54 lb/min)
- Medium temperature range: -50 to 205 °C (-58 to 401 °F)
- Max. process pressure: 430.9 bar (6250 psi)
- Wetted materials: Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Dosimass Coriolis flowmeter
The compact sensor with an ultra-compact transmitter
- Max. measurement error: Mass flow (liquid): ±0.15 %, Density (liquid): ±0.0005 g/cm³
- Measuring range: 0 to 18 000 kg/h (0 to 660 lb/min)
- Medium temperature range: –40 to +125 °C (–40 to +257 °F), 150 °C allowed for 1 h
- Max. process pressure: PN 40
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Cubemass C 100 Coriolis flowmeter
Compact sensor for smallest quantities with an ultra-compact transmitter
Predecessor: Cubemass / 8CM
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3 - Measuring range: 0 to 1000 kg/h (0 to 37 lb/min)
- Medium temperature range: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 40, Class 300, 10K, 400 bar (5800 psi)
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4539 (904L); 1.4404 (316/316L)
Proline Cubemass C 300 Coriolis flowmeter
Compact sensor for smallest quantities with a compact, easily accessible transmitter
Predecessor: Cubemass DCI / 8CN, Cubemass / 8CM
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm3 - Measuring range: 0 to 1000 kg/h (0 to 37 lb/min)
- Medium temperature range: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 40, Class 300, 10K, 400 bar (5800 psi)
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4539 (904L); 1.4404 (316/316L)
Proline Cubemass C 500 Coriolis flowmeter
Compact sensor for smallest quantities, with a remote transmitter version with up to 4 I/Os
Predecessor: Cubemass DCI / 8CN, Cubemass / 8CM
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm3 - Measuring range: 0 to 1000 kg/h (0 to 37 lb/min)
- Medium temperature range: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 40, Class 300, 10K, 400 bar (5800 psi)
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4539 (904L); 1.4404 (316/316L)
Proline Promass E 100 Coriolis flowmeter
Mid-range Coriolis flowmeter with an ultra-compact transmitter
Predecessor: Promass 80E, Promass 83E, Proline Promass E 100 / 8E1B
- Max. measurement error: Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min)
- Medium temperature range: –40 to +150 °C (–40 to +302°F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Promass E 200 Coriolis flowmeter
Genuine loop-powered mid-range Coriolis flowmeter
Predecessor: Promass 80E, Promass 83E, Proline Promass E 200 / 8E2B
- Max. measurement error: Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
- Medium temperature range: –40 to +150 °C (–40 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Promass E 300 Coriolis flowmeter
Mid-range Coriolis flowmeter with a compact, easily accessible transmitter
Predecessor: Promass 80E, Promass 83E
- Max. measurement error: Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 180 000 kg/h (0 to 6615 lb/min)
- Medium temperature range: –40 to +150 °C (–40 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Promass E 500 Coriolis flowmeter
Mid-range Coriolis flowmeter as remote version with up to 4 I/Os
Predecessor: Promass 80E, Promass 83E
- Max. measurement error: Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 180 000 kg/h (0 to 6615 lb/min)
- Medium temperature range: –40 to +150 °C (–40 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Promass F 100 Coriolis flowmeter
The flowmeter with premium accuracy, robustness and an ultra-compact transmitter
Predecessor: Promass 80F, Promass 83F
- Max. measurement error: Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
- Medium temperature range: Standard: –50 to +150 °C (–58 to +302 °F), Option: –50 to +240 °C (–58…+464 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022), Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Proline Promass F 200 Coriolis flowmeter
Robust flowmeter with genuine loop-powered technology
Predecessor: Promass 80F, Promass 83F
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³ - Measuring range:0 to 70 000 kg/h (0 to 2570 lb/min)
- Medium temperature range:Standard: –50 to +150 °C (–58 to +302 °F), Option: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022), Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Proline Promass F 500 Coriolis flowmeter
Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os
Predecessor: Promass 80F, Promass 83F, Promass 84F
- Max. measurement error: Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
- Medium temperature range: Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +240 °C (–58 to +464 °F)
High temperatur option: –50 to +350 °C (–58 to +662 °F)
Option: –196 to +150 °C (–320 to +302 °F) - Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022), Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Proline Promass G 100 Coriolis flowmeter
The most compact high-pressure sensor with an ultra-compact transmitter
Predecessor: Promass 80M
- Max. measurement error: Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 18 000 kg/h (0 to 662 lb/min)
- Medium temperature range: –50 to +150 °C (–58 to +302 °F)
- Max. process pressure: 350 bar (5080 psi)
- Wetted materials: Measuring tube: 1.4435 (316L), Connection: 1.4404 (316/316L)
Proline Promass H 100 Coriolis flowmeter
The chemically resistant single-tube flowmeter with an ultra-compact transmitter
Predecessor: Promass 80H, Promass 83H
- Max. measurement error: flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
- Medium temperature range: Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) - Max. process pressure: PN 40, Class 300, 20K
- Wetted materials: Measuring tube: Tantalum 2.5W; 702 (UNS R60702), Connection: Tantalum; 702 (UNS R60702)
Proline Promass H 300 Coriolis flowmeter
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter
Predecessor: Promass 80H, Promass 83H
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
- Medium temperature range: Tantalum: –50 to +150 °C (–58 to +302 °F), Zirconium: –50 to +205 °C (–58 to +401 °F)
- Max. process pressure: PN 40, Class 300, 20K
- Wetted materials: Measuring tube: Tantalum 2.5W; 702 (UNS R60702), Connection: Tantalum; 702 (UNS R60702)
Proline Promass H 500 Coriolis flowmeter
Chemically resistant single-tube flowmeter, as remote version with up to 4 I/Os
Predecessor: Promass 80H, Promass 83H
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
- Medium temperature range: Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) - Max. process pressure: PN 40, Class 300, 20K
- Wetted materials: Measuring tube: Tantalum 2.5W; 702 (UNS R60702), Connection: Tantalum; 702 (UNS R60702)
Proline Promass I 100 Coriolis flowmeter
Combines in-line viscosity and flow measurement with an ultra-compact transmitter
Predecessor: Promass 80I, Promass 83I
- Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: to 180 000 kg/h (0 to 6600 lb/min)
- Medium temperature range: –50 to +150 °C (–58 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: Titanium grade 9, Connection: Titanium grade 2
Proline Promass I 300 Coriolis flowmeter
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter
Predecessor: Promass 80I, Promass 83I
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min)
- Medium temperature range: –50 to +150 °C (–58 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: Titanium grade 9, Connection: Titanium grade 2
Proline Promass I 500 Coriolis flowmeter
Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os
Predecessor: Promass 80I, Promass 83I
- Max. measurement error: Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min)
- Medium temperature range: –50 to +150 °C (–58 to +302 °F)
- Max. process pressure: PN 100, Class 600, 63K
- Wetted materials: Measuring tube: Titanium grade 9, Connection: Titanium grade 2
Proline Promass K 10 Coriolis flowmeter
Flowmeter with minimized total cost of ownership with easy-to-use operation concept
Predecessor: Promass 40E
: Max. measurement error
- Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option)
Mass flow (gas): ±0.75 % - Measuring range: 0 to 180 000 kg/h (0 to 6615 lb/min)
- Medium temperature range: –40 to +150 °C (–40 to +302 °F)
- Max. process pressure: PN 40, Class 300, 40K
- Wetted materials: Measuring tube: 1.4539 (904L), Connection: 1.4404 (316/316L)
Proline Promass O 100 Coriolis flowmeter
The robust high-pressure flowmeter with an ultra-compact transmitter
- Max. measurement error: Mass flow (liquid): ±0.1 (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 800 000 kg/h (0 to 29 400 lb/min)
- Medium temperature range: –40 to +205 °C (–40 to +401 °F)
- Max. process pressure: PN 250, Class 1500
- Wetted materials: Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750), Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)
Proline Promass O 300 Coriolis flowmeter
Robust high-pressure flowmeter with a compact, easily accessible transmitter
Predecessor: Promass 83O, Promass 84O
- Max. measurement error: Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ - Measuring range: 0 to 2 200 000 kg/h (0 to 80 850 lb/min)
- Medium temperature range: –40 to +205 °C (–40 to +401 °F)
- Max. process pressure: PN 250, Class 1500
- Wetted materials: Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750), Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)